FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS 

The  user  shall  not  make  any  changes  or  modifications  to  the  equipment  unless  authorized  by  the  Installation  Instructions  or  User's  Manual.  Unauthorized  changes  or 
modifications could void the user's authority to operate the equipment. 

FCC / IC STATEMENT 

This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 

Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet 
appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une reception indésirable. 

RF EXPOSURE WARNING 

– The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) 

from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-
transmitter product procedures. 

MISE EN GARDE EXPOSITION AUX FREQUENCES RADIO: 

L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de 

séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes.

 

For the latest documentation and online support information, please go to: 

https://mywebtech.honeywell.com/ 

For the latest warranty information, please go to: 

www.honeywell.com/security/hsc/resources/wa. 

For patent information, see www.honeywell.com/patents

 

  

MyWebTech 

 

Warranty 

 

Patents 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING 
LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

 

 2014 Honeywell International Inc.  Honeywell and is a registered trademark of Honeywell International Inc.   

All other trademarks are the properties of their respective owners.  All rights reserved.    

 

6.  Reinsert the screen/sensing chamber and press 

firmly to set it in place. 

7.  Reinsert the detector cover back over the 

screen/sensing chamber and turn it clockwise until 
it locks in place. 

8.  Reinsert the batteries. 
9.  Reattach the device to the mounting plate. 

 

8

6

7

 

Maintenance 

(continued)

 

Battery Replacement 

 

Twist the front cover counterclockwise  
15 degrees and separate it from the mounting 
bracket. 

 

Remove both batteries and wait 10 seconds, 
then insert two new batteries. 
Recommended batteries: 

-

  Honeywell 466 

-

  Panasonic CR123A 

-

  Duracell DL123 or DL123A 

NOTE

:  

Do not mix old and new batteries, battery 

types or manufacturers.

  

 

Reattach to the detector to the mounting plate. 

1

5

Honeywell 466,  Panasonic CR123A

Duracell DL123,  Duracell DL123A

2

3

30

0

45

10

~

 

10

sec

4

 

Replace Batteries

 

BATTERY CAUTION:

 Risk of fire, explosion and burns. Do not recharge, 

disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries 
properly. Keep away from children. 

Specifications: 

Batteries

: Two 3V Lithium; Honeywell 466, Panasonic CR123A, Duracell DL 123 or DL 123A 

RF Frequency

: 2.4GHz 

Tamper

: Cover tamper 

Operating Temperature

:  0° to 35° C / 32° to 95° F  

Relative Humidity

:  

 

95% max. (Agency Compliance – 93% max.), non-condensing 

Maximum Spacing: 

50ft x 50ft  (refer to National Fire Alarm Code Standard NFPA 72 for 

application requirements) 

Dimensions

: 13.46 cm Diameter x 4.19 cm Thick / 5.3 in. Diameter x 1.65 in. Thick 

Approval Listings: 

FCC / IC 
ETL Listed – Conforms to UL 268 & UL 521 
cETL Listed – Certified to ULC-S529 & ULC-S530  

Other Standards: 
NFPA 72 

ANSI / SIA-CP-01 

CSFM  

RoHS

     

  

NOTE

: Smoke detectors are not to be used 

with detector guards unless the combination is 
evaluated and found suitable for that purpose. 

Ê800-15961PŠ 

800-21343  11/15  Rev A 

 

  

2 Corporate Center Drive, Suite 100 

P.O. Box 9040, Melville, NY 11747 

www.honeywell.com/security  

 

Summary of Contents for SiXSMOKE

Page 1: ...press the Test switch to restart the enrollment process The device can also be manually enrolled See the Controller s Programming Guide for details Serial Number Loop Number Zone Description 1 Zone Description 2 Device Type Response Type Alarm Report Chime Supervision Panic Home 1 3 4The Green LED is ON for 3 seconds Programming Mode Zones Add New Serial Number The LED Flashes for up to about 20 s...

Page 2: ...e Mount Test The detector should be tested immediately after installation and at least once a year Recommended To prevent unwanted alarms notify the Central Station that the smoke detector system is undergoing maintenance before testing begins Test Mode can be activated remotely from the Controller see the Controller s manual or on site by pressing the test switch Tests and testing methods Test Sw...

Page 3: ...rts chirping after 7 days and continues until the batteries are replaced or die To quiet the sounder for 5 minutes press the Test Switch does not work when set in one go all go mode See Battery Replacement section To silence the detector Press the test switch or disarm the system at the controller The detector sounds again after 5 minutes if the alarm condition continues When programmed in one go ...

Page 4: ...LIMITATIONS OF THE ENTIRE ALARM SYSTEM 2014 Honeywell International Inc Honeywell and is a registered trademark of Honeywell International Inc All other trademarks are the properties of their respective owners All rights reserved 6 Reinsert the screen sensing chamber and press firmly to set it in place 7 Reinsert the detector cover back over the screen sensing chamber and turn it clockwise until i...

Reviews: