background image

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used 
in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installa-
tion. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures:
 

 

 

– Reorient or relocate the receiving antenna.

 

 

 

– Increase the separation between the equipment and receiver.

 

 

 

– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

 

 

 

– Consult the dealer or an experienced radio/TV technician for help.

FCC STATEMENT

FIGURE 8. EXAMPLE OF MULTIPLE BOARDS SHARING SAME EXTERNAL SUPPLY

Refer to figures 8 and 9 for typical wiring. Make certain lip on long power supply jumper engages retaining tab on T5 or T6 as shown in View A-A.

ó

+

ó

+

+0

+1

IDC ADDRESS

ó

+

ó

+

+2

+3

IDC ADDRESS

ó

+

ó

+

+4

+5

IDC ADDRESS

SLC

ó

+

ó

+

A/B SELECT

A/B SELECT

DISABLE 

1

DISABLE 

2

T6

T5

ó

+

ó

+

+0

+1

IDC ADDRESS

ó

+

ó

+

+2

+3

IDC ADDRESS

ó

+

ó

+

+4

+5

IDC ADDRESS

SLC

ó

+

ó

+

A/B SELECT

A/B SELECT

DISABLE 

1

DISABLE 

2

T6

T5

IN

OUT

ó

+

ó

+

EXTERNAL SUPPLY

IN

OUT

ó

+

ó

+

EXTERNAL SUPPLY

EXTERNAL

POWER

SUPPLY

ó

+

PCB 1

PCB 2

VIEW A-A

0

1 2

3 4 5

6

7

8

9

BASE

ADDRESS

0

1 2

3 4 5

6

7

8

9

0

1 2

3 4 5

6

7

8

9

BASE

ADDRESS

0

1 2

3 4 5

6

7

8

9

10

11

12

13

14

15

10

11

12

13

14

15

 

 C0142-02

DEVICE AND SYSTEM SECURITY

Before installing this product ensure that the tamper seal on the packaging is present and unbroken and the product has not been tampered with since leaving the factory. Do not 
install this product if there are any indications of tampering. If there are any signs of tampering the product should be returned to the point of purchase.
It is the responsibility of the system owner to ensure that all system components, i.e. devices, panels, wiring etc., are adequately protected to avoid tampering of the system that could 
result in information disclosure, spoofing, and integrity violation.

  4 

I56-3441-007 

  

©2022 Honeywell. 7/1/2022

Silent Knight

®

, System Sensor

®

, and Honeywell

®

 are registered trademarks of Honeywell International, Inc.

Summary of Contents for SILENT KNIGHT SK-Zone-6

Page 1: ...ally assigned to the next five higher addresses Provisions are included for disabling a maximum of two unused modules to release the addresses to be used elsewhere Each mod ule also has panel controlled bicolor LED indicators The panel can cause the LEDs to blink latch on or latch off Included 5 1 x 4 Terminal Blocks 2 1 25 Stand offs 3 Shunts 4 Machine Screws 2 Nuts 1 Long Power Supply Jumper 6 3...

Page 2: ...ited represent Power Limited Class 2 1 Install module wiring in accordance with the job drawings and appropri ate wiring diagrams 2 All wiring to the SK Zone 6 is done via terminal blocks In order to prop erly make electrical connections strip approximately 0 25 of insulation from the end of wire sliding the bare end of the wire under the clamping plate screw 3 Set the address on the modules per t...

Page 3: ...ATORS 0 1 IDC ADDRESS 2 3 IDC ADDRESS 4 5 IDC ADDRESS SLC FROM PANEL OR PREVIOUS DEVICE CONNECT MODULES TO LISTED COMPATIBLE SILENT KNIGHT CONTROL PANELS ONLY SIGNAL LINE CIRCUIT SLC 32 VDC MAX SEE PANEL INSTRUCTION MANUAL FOR WIRE REQUIREMENTS CLASS A IDC TYPICAL A B SELECT A B SELECT DISABLE 1 DISABLE 2 IDC 2 IDC 3 POWER TO THE NEXT INTERFACE MODULE MUST BE EXTERNALLY SWITCHED TO RESET THE DETEC...

Page 4: ...erienced radio TV technician for help FCC STATEMENT FIGURE 8 EXAMPLE OF MULTIPLE BOARDS SHARING SAME EXTERNAL SUPPLY Refer to figures 8 and 9 for typical wiring Make certain lip on long power supply jumper engages retaining tab on T5 or T6 as shown in View A A ó ó 0 1 IDC ADDRESS ó ó 2 3 IDC ADDRESS ó ó 4 5 IDC ADDRESS SLC ó ó A B SELECT A B SELECT DISABLE 1 DISABLE 2 T6 T5 ó ó 0 1 IDC ADDRESS ó ó...

Reviews: