background image

 

 

 

Find out more 

www.honeywellanalytics.com 

Contact Honeywell Analytics: 

Americas 

Honeywell Analytics, Inc. 

405 Barclay Blvd. 

Lincolnshire, IL 60069 

USA 
Tel: +1 847 955 8200 

Toll free: +1 800 538 0363 

Fax: +1 847 955 8210 
[email protected] 

Europe, Middle East, Africa 

Life Safety Distribution GmbH 

Javastrasse 2 
8604 Hegnau 

Switzerland 

Tel: +41 (0)44 943 4300 
Fax: +41 (0)44 943 4398 

[email protected] 

Asia Pacific, India 

Honeywell Analytics Asia Pacific, Co., Ltd. 

7F SangAm IT Tower 

434 Worldcup Buk-ro, Mapo-gu 

Seoul 03922 
South Korea 

Tel: +82 (0)2 6909 0300 

Fax: +82 (0)2 2025 0388 

India Tel: +91 124 4752700 
China Tel: +86 10 5885 8788 3000 

[email protected] 

 
www.honeywell.com  

 

Copyright © 2016 Honeywell Analytics Co., Ltd.  
All rights reserved. 

For full operating 

instructions

 

Summary of Contents for Sensepoint XCL

Page 1: ...Gas Detec on Sensepoint XCL Fixed Gas Detector Quick Start Guide ...

Page 2: ...ions 1 24 V DC or 24 V AC 2 0 V or 24 V AC 3 4 to 20 mA 4 Common 3 Modbus RTU Output Versions 1 24 V DC or 24 V AC 2 0 V or 24 V AC 3 A 4 B 4 Relay Output 1 Normally closed NC 2 Common 3 Normally open NO 5 Securing the Back Box to a Wall 1 There are four screw positions in the rear of the back box for mounting purposes Punch the required screw positions or drill using a 4 mm drill 2 Secure the bac...

Page 3: ...o ensure stable Modbus communications and to limit the effects of radio frequency interference Ground points are provided inside the back box In order to prevent false readings or alarms as a result of ground loops ensure that the shield of all cables are grounded at a single point preferably at the controller Consideration should also be given to how conduit glands and the internal earth plate ar...

Page 4: ...ndicator on its front face Normal The indicator is lit GREEN when the concentration of the target gas is within normal range The Normal indication can also be set to Confidence Flash or Off Alarm RED flashes rapidly when the gas concentration is beyond the alarm level threshold Fault YELLOW flashes rapidly when the gas detector is in a fault state Bluetooth pairing BLUE flashes when Bluetooth pairing ...

Page 5: ...al output Modbus RTU Relay output 2 dry contact relays for fault and alarm signalling Rated at 5 A 24 V DC 5 A 240 V AC Operating Environment Operating temperature 20 to 50 C 4 to 122 F Storage temperature 0 to 30 C 32 to 86 F Humidity 0 to 99 non condensing Atmospheric pressure 90 to 110 kPa Ingress protection IP65 Type 4 in accordance with NEMA 250 Installation category II UL CSA IEC EN 61010 1 ...

Page 6: ...on GmbH Javastrasse 2 8604 Hegnau Switzerland Tel 41 0 44 943 4300 Fax 41 0 44 943 4398 gasdetection honeywell com Asia Pacific India Honeywell Analytics Asia Pacific Co Ltd 7F SangAm IT Tower 434 Worldcup Buk ro Mapo gu Seoul 03922 South Korea Tel 82 0 2 6909 0300 Fax 82 0 2 2025 0388 India Tel 91 124 4752700 China Tel 86 10 5885 8788 3000 analytics ap honeywell com www honeywell com Copyright 20...