background image

Residential and

Residential and

Helping You Control Your World

Building Controls Division

Building Controls Division

Honeywell Inc.

Honeywell Limited—Honeywell Limitée

1985 Douglas Drive North

740 Ellesmere Road

Golden Valley, MN 55422

Scarborough, Ontario
M1P 2V9

QUALITY IS KEY

Summary of Contents for S9201A1010

Page 1: ...ing Igniter surface area immersed in flame must not ex ceed1 4ofthegroundedareaimmersedinflame This would prevent flame sensing Igniter current draw at 132 Vac must not exceed 5 A 2 Check the ratings given in these instructions to make sure the integrated furnace control is suitable for your appli cation 3 Installer must be a trained experienced service techni cian 4 After installation is complete...

Page 2: ...en burner and S9201 1 4 in male Transformer secondary quick connects Field 120 Vac Screw terminals Humidifier and electronic air cleaner 24 Vac Screw terminals Thermostat WIRING CAUTION 1 Check the wiring diagram furnished by the appli ance manufacturer if available for circuits differing from the general hookup shown Carefully follow anyspecialinstructionsaffectingthegeneralproce dures outlined b...

Page 3: ...roubleshooting Check Safety Shutoff Operation Shut off gas supply at manual gas valve ahead of appli ance Set thermostat to call for heat System should operate as indicated in Table 4 Following lockout open manual gas valve and make sure no gas is flowing to burner TABLE 4 S9201A1010 SEQUENCE ON FAILURE TO LIGHT FIG 2 LADDER DIAGRAM OF S9201 INTEGRATED FURNACE CONTROL 1 POWER SUPPLY PROVIDE DISCON...

Page 4: ...neral guide Follow appliance manufacturer s service in structions if available 2 All meter readings must be taken within the trial for ignition period Once the ignition period ends the system must be reset by setting the thermostat down for at least 45 sec before continuing 3 If any component does not function properly make sure it is correctly installed and wired before replac ing it 4 Staticdisc...

Page 5: ...NS POWERED AND LIT YES YES YES YES NO NO INDOOR BLOWER MOTOR STARTS AFTER 30 SECONDS CHECK FOR 120 VAC ACROSS BLOWER MOTOR AND BLOWER MOTOR TERMINALS ON IFC REPLACE IFC IF WIRING TO BLOWER MOTOR IS OK M890 NOTE If IFC goes into lockout wait 30 seconds then reset system CHECK CONTINUITY OF GROUND WIRE NOTE IF GROUND IS POOR OR ERRATIC SHUTDOWN MAY OCCUR OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL ...

Page 6: ...ng You Control Your World Building Controls Division Building Controls Division Honeywell Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley MN 55422 Scarborough Ontario M1P 2V9 QUALITY IS KEY ...

Reviews: