TK_S014 – Installation Manual
i
Installation Manual
Temaline
TK_S014 (RTU A08)
Page 1: ...TK_S014 Installation Manual i Installation Manual Temaline TK_S014 RTU A08 ...
Page 2: ...d in its written agreement with and for its customer In no event is Honeywell liable to anyone for any direct special or consequential damages The information and specifications in this document are subject to change without notice Copyright 2016 Honeywell International Inc Honeywell trademarks Tema VoyagerTM is a trademark of Honeywell International Inc MIFARE is a registered trademark of Philips...
Page 3: ... Readers wires 10 MOUNTING THE DEVICE 12 MOUNTING ON DIN OMEGA RAIL 12 MOUNTING THE DEVICE INTO ENCLOSURES 12 CLOSING THE RTUA08 MODULE 13 WIRING OPERATION 14 ELEMENTAL DETAIL 14 CONNECTION OF POWER SUPPLY CABLES 14 CONNECTION OF THE LONWORK CABLES 14 Daisy chain connection BUS 15 Free topology connection STAR 15 Lonwork cables connection 16 CONNECTIONS OF READER CABLES 16 CONNECTING THE DOOR 17 D...
Page 4: ...TION BETWEEN RTUA08 AND TEMASERVER 20 COLLECTING DEVICE INFORMATION 21 TECHNICAL DATA 22 REGULATION COMPLIANCE 24 CE COMPLIANCE 24 FCC NOTICE 24 CANADIAN AND UNITED STATES UL LISTED 24 ROHS COMPLIANCE 25 WEEE COMPLIANCE 25 CHINA ROHS DECLARATION 25 MEANING OF GRAPHICAL SYMBOLS USED 26 ...
Page 5: ...RTU A08 device can be used together with other Temaline devices to compose a TemaKey there are different TemaKey types that differ from the type of Human Machine Interface they have Each TemaKey consists of one or more RTU modules that must be positioned and connected to their respective wall attachment frames RTU Sxx as indicated in the table below Here below the list of TemaKeys can be composed ...
Page 6: ...de Composition Notes TK_T014 RTU C01 RTU T01 RTU A08 2 RTU S01 1 third party Wiegand reader Horizontal mounting Weight 1 05Kg Power 3 3W Current 240mA Excluding reader current RTU C01 RTU T01 RTU A08 2 RTU S01 2 third party Wiegand readers Horizontal mounting Weight 1 05Kg Power 3 3W Current 240mA Excluding reader current The 2 readers are on the same door one in entry and one in exit direction In...
Page 7: ...Access Control Configuration Guide Further information on the EBI Tema system complete commissioning steps and system configuration are included in the which is provided with EBI documentation package Temaline installation in Harsh Environment It is a whitepaper with Temaline system rules on this topic ...
Page 8: ...unting tools The following screwdrivers are required for the installation One small flat screwdriver One 0 1 flat head screwdriver System Architecture This is a typical system architecture in which the RTU A08 is inserted Figure 1 RTU A08 architecture The devices represented are TemaServer is the controller that manages the RTU A08 It can be both a TS AC and a TS2 device TemaPower is the power sup...
Page 9: ... 35 52 67 34 13 7 3 1 Table 1 Length Capacity of Power Cables m LONWORKS Data Cables The LONWORKS data cable must be twisted pair In a free topology configuration the total length of the sections must not exceed 500m In a bus configuration the total length of the sections must not exceed 2700m In a free topology configuration activate the 51 ohm terminator by placing the appropriate jumper on the ...
Page 10: ...Cat5 900 250 450 Table 3 Recommended LONWORKS Cables Input wires Use a twisted pair cable for the contacts connections For outdoor wiring is mandatory to use shielded cables The cables shielding must be connected to the respective ground connectors V For internal wiring without shielded cables is recommended an electrical environment where the cables are well separated even at short runs especiall...
Page 11: ...TK_S014 Installation Manual 11 The wires used to connect the RTU A08 to the reader s are those specified into the reader technical specification ...
Page 12: ...e rail See Figure 2 CLIP R O TATIO N Figure 2 Mounting onto the DIN Rail Mounting the device into enclosures Often a device is mounted together with others inside large enclosures with DIN omega rails that provide enough space for access and wire When a device need to be mounted into a small enclosure it minimum size must follow the dimensions reported in the next figure 120mm Min 150mm Min Intern...
Page 13: ...g the RTUA08 Module To close the unit follow these steps see Figure 4 Clip the cover onto the module Screw on the module cover with the 4 self tapping screws requires a 3mm cross head screwdriver RTU A08 Figure 4 Closing the RTUA08 Module ...
Page 14: ...the main connectors and service elements Figure 5 Elemental Detail Connection of power supply cables The RTU A08 device must be powered with a 12V DC power supply To determine the correct size of the power cable please refer to Table 1 Length Capacity of Power Cables m Table 1 Figure 6 Power Supply connection Connection of the Lonwork cables ...
Page 15: ...ponds to the norms indicated in Table 2 In a bus configuration place two terminators with resistance values of 100ohm 1 W at each end of the bus Figure 7 Daisy chain BUS connection Free topology connection STAR The LONWORKS data cable must be twisted pair In a free topology configuration the total length of the sections must not exceed 500m Check that the length of the LONWORKS data cable correspo...
Page 16: ...abling Refer to the above chapters on the different Lonwork wiring typologies for the related terminators details Connections of Reader cables Connect the shielded cables coming from the readers to the terminal screws on the RTUA08 as shown in Figure 10 The shields must be connected directly to the main earth ground GND Wiegand0 Wiegand1 LED RED LED GREEN BUZZER 12V READER 1 GND Wiegand0 Wiegand1 ...
Page 17: ...IN 12V SUPPLY IN GND GND WIE0 IN1 WIE1 IN1 LED RED1 LED GREEN1 BUZZER1 12VRDR 12LOCK GND WIE0 IN2 WIE1 IN2 LED RED2 LED GREEN2 BUZZER2 12VRDR GND GND GND JP1 JP2 1 2 3 Figure 11 Door Connection Using 14V Internal Power Supply Be aware that even if the diode is already embedded in the unit in some cases long cable installed near the inputs cables may be useful to add an external diode provided with...
Page 18: ...Be aware that even if the diode is already embedded in the unit in some cases long cable installed near the inputs cables may be useful to add an external diode provided with the unit close to the relay device Setting the normality value for the outputs Jumpers JP1 and JP2 are used to set the normality value for the Output of the device The factory setting for the jumpers is Normally Open NO JP1 s...
Page 19: ...e 10mt an Electromagnetic source is a device that generates high electromagnetic noise at frequency from 150Kz to 1 Ghz tested up to 10V m 61000 4 6 or Power frequency magnetic noise tested up to 100V m 61000 4 8 Cables rules INPUT cables door side shielded to local Earth ground Shield type braid shield 90 coverage OUT Cables door side shielded to local Earth ground Shield type braid shield 90 cov...
Page 20: ... device that manages it through the Lonwork wire RTU A08 powered and working The TemaServer powered and working To check the RTU A08 communication you can activate the device service pin using the button located inside the module To do this follow these steps 1 Push the internal service button 2 The TemaServer will send a wink in response to the service pin that will cause the yellow Led to remain...
Page 21: ...ing identification form and indicate the location of the terminal in the appropriate box see example in Table 5 The information collected can then be used for the RTU configuration on EBI Temaline application Description of location Office entrance area first floor staircase A Description of TemaServer Panel 2 entrance area first floor staircase A RTU A08 RTU RTU RTU Table 5 Example of Completed I...
Page 22: ...urrent 0 3 mA Voltage absolute max 24V 40V Wire length connection total resistance 10 Ohm not shielded Min detection time 250 ms Wiegand Inputs Type Wiegand normally high Number 2 Voltage 0V 5V nominal TTL 14V Max Timing BIT Pulse width min 50us max 10ms BIT Interval time min 500us max 20ms BIT Interval BIT Interval BIT Pulse D0 D1 BIT Pulse BIT Pulse Wire type and length connection see the reader...
Page 23: ...D Green LED Buzzer Voltage 0V 14V max Current 80mA Max Wire length connection see installation manual usually shielded Outputs Type Power Open Collector Drain Number 2 Voltage 10V 14V internal Power supply Voltage absolute max 10V 30V from external Power supply Current 1 2A 5A 2sec peak max inductive load Normality1 NO or NC via JP1 and JP2 Default NO Wire length connection it depends on cable dia...
Page 24: ... and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However this is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuning the equipment off and on the us...
Page 25: ...ry 2014 Honeywell commits when requested by the customer to the collection treatment recovery and disposal of apparatus produced Customers in European Union are advised to dispose this product at the end of its useful life as per applicable local laws regulations and procedures China RoHS declaration This product contains toxic and hazardous substances or elements over the defined maximum concentr...
Page 26: ...transport package are fragile and the package shall be handled with care Carton Box This way up To indicate correct upright position of the transport package Carton Box Conformité Européenne To indicate the manufacturer declares that the product meets the requirements of the applicable EC directives Label Canadian and United States UL Listed To indicate that the product meets the requirements of t...