background image

RPLS740B/RPLS741B

1/8

The RPLS740B/RPLS741B programmable wall switch has been designed to control lights and motors:

Cut power at the circuit breaker to avoid electric shock.

Remove the existing switch.

Install the new switch (see the appropriate section below).

Apply power at the circuit breaker.

The RPLS740B/RPLS741B will turn the lights on at sunset and turn them off at 11:00 pm by default. If these
settings are appropriate for you, you only need to set the time and date (see shaded zone in the menu
flowchart sheet). If the switch’s sunset time does not correspond to the actual sunset time, see sections 5.3.3
and 5.3.4.

5.1

Mode Menu

You can use the Mode menu to select one of the three modes of operation (see sections 5.1.1 to 5.1.3).

5.1.1 Manual Mode 

In Manual mode, the RPLS740B/RPLS741B operates like a regular switch. To turn the
lights on or off, briefly press the main button. The   icon appears when the switch is in
Manual mode.

5.1.2 Automatic Mode 

In Automatic mode, the RPLS740B/RPLS741B turns the lights on or off according to the
set programs (see Section 5.4). The 

 icon as well as the current program number are

displayed.

5.1.3 Random Mode 

In Random mode, the RPLS740B/RPLS741B has no specific times to turn the lights on or
off. This mode is designed to give the impression the house is occupied during your
absence. It is similar to the Automatic mode except there is no fixed program. The
programs are automatically set to different times by the RPLS740B/RPLS741B every day.
The 

 icon appears when the switch is in Random mode.

The first “On” program occurs at sunset. Each “On” program lasts between 1 hour and 1
hour and 30 minutes; each “Off” program lasts between 15 and 30 minutes. The last “Off”
program occurs between 10:30 pm and midnight.

5.1.4 Temporary Override

When the RPLS740B/RPLS741B is in Automatic or Random mode, you can press the main button at any
time to override the default state for the current program. The lights will turn off if they are on and vice versa.
The icon (On or Off) of the new state flashes to indicate that the state is temporary. The new state is
maintained until you press the main button again or till the next “On” or “Off” program.

5.2

Time Menu

The time display flashes on the screen when the time has not yet been set or after a 4-hour power outage.
Use the Time menu to select the time format (12-hour or 24-hour) and to set the clock and date.

NOTE

: The date is used to determine the sunset and sunrise times.

5.3

Configuration Menu

 (

Conf

)

Use the Configuration menu to set the following parameters (see sections 5.3.1 to 5.3.4).

5.3.1 Backlight mode (

SCRN

)

The screen is lit at high intensity for 8 seconds when you press any button. The rest of the time, depending
on the backlight mode selected, the screen behaves as follows:

Scrn Off

: The screen is not lit.

Scrn On HI

: The screen is lit at high intensity.

Scrn On LO

: The screen is lit at low intensity (default mode).

5.3.2 Automatic Daylight Savings Time Changeover (

DLS

)

When automatic daylight savings time changeover is on (DLS On), the RPLS740B/RPLS741B changes to
daylight savings time (summer time) at 2:00 am on the second Sunday of March and changes back to
normal time (winter time) at 2:00 am on the first Sunday of November. This function is enabled (DLS On) by
default.

5.3.3 Latitude and Longitude Coordinates (

LAT and LONG

)

The coordinates are used to turn the lights on at sunset and off at sunrise. The latitude is set to +45 and lon-
gitude to -75 by default. These settings provide approximate sunset and sunrise times for most North Ameri-
can cities. To obtain your city’s coordinates (or those of a nearby city), see the coordinates table. You can

Applications

1.

Load types

Maximum load

Examples

Lights and resistive 
loads (except tungsten)

1800 W 
(15 A @ 120 V)

fluorescent lights

compact fluorescent lights (CFL)

electronic ballasts

sodium lamps

block heaters

Tungsten lights

1440 W 
(12 A @ 120 V)

incandescent lights

halogen lights

Motors

3/4 hp

pool filter pumps

fans

Installation

2.

NOTE:

This switch cannot be used if there is no neutral wire 
(white wires joint together) inside the electrical box.

Quick Start-up

3.

Set the time and date before using the timer for the first time.

Operation

4.

120
VAC

black

white

black

white

black (LINE)

white (NEUTRAL)

blue (LOAD)

The   icon indicates the current 
program has been activated at sunset.
The 

 icon indicates the current 

program has been activated at sunrise.

The LED illuminates when the load state 
is on.

Briefly press this button to turn the 
lights on or off. See “Temporary 
Override” in Section 5.1.4.

Press for 3 seconds to enter the 
setup menus.

Indicates the mode of 
operation (see Section 5.1)

Indicates the current program

Indicates the load on/off state

Indicates the time and day

Press this button to display today’s sunrise time.
Press this button to display today’s sunset time.

Setup Menus

5.

Press the main button for 3 seconds to enter the setup menus. Refer to 
the menu flowchart sheet on how to navigate the menus.

(3 sec.) 

RPLS740B/RPLS741B

User guide

7-day Solar Programmable Wall Switch

69-2455EFS-01_400-071-003-A (TI071_RPLS740B) USA.book  Page 1  Tuesday, May 18, 2010  10:49 AM

Summary of Contents for RPLS740B

Page 1: ...5 3 Configuration Menu Conf Use the Configuration menu to set the following parameters see sections 5 3 1 to 5 3 4 5 3 1 Backlight mode SCRN The screen is lit at high intensity for 8 seconds when you press any button The rest of the time depending on the backlight mode selected the screen behaves as follows Scrn Off The screen is not lit Scrn On HI The screen is lit at high intensity Scrn On LO Th...

Page 2: ...ts more than 4 hours all other settings and programs are permanently saved Latitude range from 65 to 65 Solar table precision 11 min within 60 latitude Certification UL c UL us Honeywell warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and ser vice for a period of one 1 year from the date of purchase by the con sumer If at any time du...

Page 3: ...ainsi que pour régler l horloge et la date NOTA La date sert à déterminer l heure du coucher du soleil et celle du lever du soleil 5 3 Menu Configuration Conf Utiliser le menu Configuration pour régler les paramètres suivants voir les sections 5 3 1 à 5 3 4 5 3 1 Mode de rétroéclairage SCRN L écran est allumé à haute intensité pendant 8 secondes lorsque vous appuyez sur un bouton Le reste du temps...

Page 4: ...ionnement 15 C à 50 C 5 F à 122 F Température d entreposage 40 C à 60 C 40 F à 140 F Panne de courant L écran est éteint Seule l heure doit être réglée si la panne dure plus de 4 heures les autres réglages et les programmes sont conservés de façon permanente Plage de latitude de 65 à 65 Précision du tableau solaire 11 min latitudes inférieures à 60 Certification UL c UL us Honeywell garantit ce pr...

Page 5: ...ustar los parámetros siguientes ver las secciones 5 3 1 a 5 3 4 5 3 1 Modo de iluminación de fondo SCRN La pantalla se ilumina con gran intensidad durante 8 segundos cuando se presiona cualquier botón El resto del tiempo según el modo de iluminación de fondo elegido la pantalla hace lo siguiente Scrn Off la pantalla no está iluminada Scrn On HI la pantalla está iluminada con gran intensidad Scrn O...

Page 6: ...140 F Corte de corriente la pantalla se apaga Si el corte dura más de 4 horas sólo hay que ajustar la hora ya que los demás ajustes y los programas se conservan de manera permanente Margen de latitud de 65 a 65 Precisión del cuadro solar 11 min latitudes inferiores a 60 Certificación UL c UL us Honeywell garantiza por un período de un 1 año a partir de la fecha de compra por el consumidor que este...

Page 7: ...ce bouton pour accepter le réglage et afficher le prochain paramètre Presionar brevemente este botón para aceptar el ajuste y visualizar el parámetro siguiente Backlight Rétroéclairage Retroiluminación sec 5 3 1 3 sec Minutes setting Réglages des minutes Ajuste de los minutos or ou Offset setting Réglage de l écart Ajuste de la desviación None selected Nul None sélectionné Ninguno None seleccionad...

Page 8: ...8 84 1 LINCOLN 40 96 0 LITTLE ROCK 34 92 0 LONG BEACH 33 118 0 LOS ANGELES 34 118 0 LOUISVILLE 38 85 1 LUBBOCK 33 101 1 MACON 32 83 1 MADISON 43 89 0 MEMPHIS 35 90 0 MIAMI 25 80 0 MILWAUKEE 43 87 0 MINNEAPOLIS 44 93 0 MOBILE 30 88 0 MODESTO 37 120 0 MONTGOMERY 32 86 0 NASHVILLE 36 86 0 NEW ORLEANS 29 90 0 NEW YORK 40 74 0 NORFOLK 36 76 0 OKLAHOMA CITY 35 97 0 OMAHA 41 95 0 ORLANDO 28 81 0 OVERLAND...

Reviews: