background image

RPLS530A/RPLS531A

1/6

RPLS530A/RPLS531A

Installation and User Guide

Programmable Wall Switch

The RPLS530A/RPLS531A switch can be used in a single-pole or 3-way
installation with the following types of lighting:

• Incandescent
• Halogen
• Low-voltage halogen with transformer
• Fluorescent

The RPLS530A/RPLS531A switch cannot be used with a load below 40
W, a load above 500 W or a motor. 

Cut power at the circuit breaker to avoid electric shock.

Remove the existing switch. (For a 3-way installation, identify and 
label the wire that is connected to the “common” screw.)

Install the new switch (refer to the appropriate section below).

Apply power at the circuit breaker.

SINGLE-POLE INSTALLATION

Connect wires "2" and "C" of the RPLS530A/RPLS531A to the line
(120 V) wire.

EXISTING 3-WAY INSTALLATION

Connect wire "C" of the RPLS530A/RPLS531A to the "common" wire,
identified when removing the old switch. Connect the other two
RPLS530A/RPLS531A wires to the two remaining wires.
At the other 3-way switch, connect the jumper wire between the "com-
mon" screw and the screw where wire "1" of the RPLS530A/RPLS531A
is connected.

NEW 3-WAY INSTALLATION

The jumper wire is not required in this installation. A single-pole switch
can be used as the other switch in a 3-way installation.

Pry the switch door open from the 
bottom using a small screwdriver.

Ensure the 

ON/OFF

 selector is set to 

ON.

Reset the switch using a paper clip. 

0:00

 and 

MO

 will flash.

If the display is blank:

Ensure the 

ON/OFF

 selector is prop-

erly engaged in the 

ON

 position. Push it to the right using a small

screwdriver.

If the programmable switch controls a lamp equipped with a built-in
On/Off switch, ensure the lamp switch is set to On.

Ensure the light bulb is not burned out and is tightly screwed in its socket.

EXISTING 3-WAY INSTALLATION

If either switch does not work properly, rewire the jumper between the
"common" screw and the other screw.

WARNING

: Before replacing the light bulb, place the 

ON/OFF

 selector in

the 

OFF

 position. Failure to do so might damage the switch.

NOTE

: The switch displays the time in 24-hour format by default or fol-

lowing a reset. 

To change to 12-hour format (or vice versa),  proceed as follows:
a) Press one of the control buttons to ensure the 

MAN

 or 

AUTO

 

indicator is displayed.

b) Press  the 

MIN

 and 

HOUR

 buttons simultaneously and brieftly 

(

0:00

 display = 24-hour, 

12:00

 display = 12-hour ).

Set the time using the 

HOUR

 and 

MIN

 buttons. If you have selected 

the 12-hour format, ensure that 

PM

 appears on the screen when an 

afternoon time is displayed.

Set the day by using the 

DAY

 button.

Press one of the control buttons or close the switch door to return to 
normal operation.

Applications

1.

Installation

2.

NOTE A: 

   

The white wire is not the neutral wire but the wire going to the load.

Line

Neutral

See NOTE A

120 VAC

Line

Neutral

120 VAC

Red

120 VAC

Jumper

Red

3-wire cable

See NOTE A

Power-On

3.

Setting the Clock

4.

120 VAC

See NOTE A

Control (4)

Reset

On/Off selector

http://waterheatertimer.org/Honeywell-timers.html

Summary of Contents for RPLS530A

Page 1: ...per clip 0 00 and MO will flash If the display is blank Ensure the ON OFF selector is prop erly engaged in the ON position Push it to the right using a small screwdriver If the programmable switch controls a lamp equipped with a built in On Off switch ensure the lamp switch is set to On Ensure the light bulb is not burned out and is tightly screwed in its socket EXISTING 3 WAY INSTALLATION If eith...

Page 2: ... shall repair or replace it at Honeywell s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii call Honeywell Customer Care at 1 800 468 1502 Customer Care will make the determination whether the product should be returned to the following address Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Dr N...

Page 3: ...urer que le sélecteur ON OFF est placé à ON Réinitialiser l interrupteur à l aide d un trombone 0 00 clignotera à l écran Si rien n est affiché à l écran S assurer que le sélecteur ON OFF est bien mis à la position ON Le placer bien à droite à l aide d un petit tournevis Si l interrupteur commande une lampe munie d un interrupteur inté gré placer son interrupteur à Marche On S assurer que l ampoul...

Page 4: ...e produit est défectueux i le retourner accompagné d une preuve d achat indiquant la date d achat à l endroit où il a été acheté ou ii s adresser au Service à la clientèle de Honeywell en composant le 1 800 468 1502 Le Service à la clientèle déterminera alors si le produit doit être retourné à l adresse suivante Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Dr N Golden Valley MN 55422 ou si...

Page 5: ... esté en ON Presionar en Reinicialización con la ayuda de un sujetapapeles 0 00 parpadeará en la pantalla Si en la pantalla no apareciera nada Asegurarse de que el selector ON OFF esté bien colocado en ON Empujarlo a la derecha con un pequeño destornillador Si el interruptor controla una lámpara con un interruptor integrado poner el interruptor de la lámpara en encendido On Asegurarse de que la bo...

Page 6: ...ier momento durante el período de vigencia de la garantía se determina que el producto es defectuoso o que funciona mal Honey well lo reparará o lo reemplazará a elección de Honeywell Si el producto es defectuoso I Devuélvalo al lugar donde lo compró acompañado por la factura de compra o de otra prueba de compra que incluya la fecha II Llame al servicio de atención al cliente de Honeywell al 1 800...

Reviews: