![Honeywell Round Professional Install Manual Download Page 14](http://html.mh-extra.com/html/honeywell/round/round_professional-install-manual_154368014.webp)
14
Setup options
1
From the Contractor Menu, highlight
Set Up
and press
OK
.
2
Press
s
or
t
to highlight the setting and press
OK
. Continue until all settings
have been configured.
3
When all settings are configured, you will be prompted to save changes.
Highlight
Yes
and press
OK
to save and exit. To exit setup early by pressing
t
to highlight
EXIT
and press
OK
.
ISU # Description
Setting
1160
Temperature
indication scale
0 = Fahrenheit
1 = Celsius
2120
Heating system
type
1 = Conventional forced air heat
2 = Heat pump
3 = Radiant heat
5 = None (cool only)
2140
Heating equipment
type
Conventional Forced Air Heat:
1 = Standard efficiency gas forced air
2 = High efficiency gas forced air
3 = Oil forced air
4 = Electric forced air
5 = Hot water fan coil
Heat Pump:
7 = Air to air heat pump
8 = Geothermal heat pump
Radiant Heat:
9 = Hot water radiant heat
12 = Steam