background image

19

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions.  

Most problems can be corrected quickly and easily.

Display is blank 

• 

Check circuit breaker and reset if necessary.

• 

Make sure power switch at heating & cooling system is on.

• 

Make sure furnace door is closed securely.

• 

Make sure fresh AA alkaline batteries are correctly installed.

Temperature 

settings do not 

change

Make sure heating and cooling temperatures are set to acceptable 

ranges:

• 

Heat: 40° to 90 °F (4.5° to 32 °C).

• 

Cool: 50° to 99 °F (10° to 37 °C).

Heating or 

cooling system 

does not respond

• 

Press 

SYSTEM

 to set system to Heat. Make sure the temperature 

is set higher than the Inside temperature.

• 

Press 

SYSTEM

 to set system to Cool. Make sure the temperature 

is set lower than the Inside temperature.

• 

Check circuit breaker and reset if necessary.

• 

Make sure power switch at heating & cooling system is on.

• 

Make sure furnace door is closed securely.

• 

Wait 5 minutes for the system to respond.

Cannot change 

system setting 

to Cool

• 

Check Function 0170: System Type to make sure it is set to 

match your heating and cooling equipment.

Fan does not 

turn on when 

heat is required

• 

Check Function 0180: Heating Fan Control to make sure it is set 

to match your heating equipment.

Heating system 

is running in cool 

mode

• 

Check Function 0170: System Type to make sure it is set to 

match your heating and cooling equipment.

Red light is on

• 

If thermostat is in Emergency Heat mode the red light is normal. 

It shows that the thermostat is in emergency heat mode.

• 

If thermostat is not in Emergency Heat mode, contact a qualified 

service contractor for repair.

“Wait” appears 

on the screen

• 

Compressor protection feature is engaged. Wait 5 minutes for the 

system to restart safely, without damage to the compressor.

Heat pump 

issues cool air 

in heat mode, or 

warm air in cool 

mode

• 

Check Function 0190: Heat Pump Changeover Valve to make 

sure it is properly configured for your system.

For assistance with this product, please visit http://yourhome.honeywell.com or 

call Honeywell Customer Care toll-free at 1-800-468-1502.

Special features

Summary of Contents for RET97D series

Page 1: ...1 Label wires and remove your old thermostat 2 Install and wire your new thermostat 3 Set your new thermostat to match your heating cooling system This thermostat works with virtually all System Types It is preset for the most common system Do you need assistance We are here to help Call 1 800 468 1502 for wiring assistance before returning the thermostat to the store ...

Page 2: ...ermostat recycling in Canada please refer to Switch the Stat at www switchthestat ca NO MERCURY NO BOTE MERCURIO Hg Customer assistance For assistance with this product please visit http yourhome honeywell com Or call Honeywell Customer Care toll free at 1 800 468 1502 To save time please note your model number and date code before calling Pull at bottom to remove thermostat from wallplate Turn th...

Page 3: ... and operation Setting the clock 14 Adjusting program schedules 15 Overriding schedules temporarily 16 Overriding schedules permanently 16 Auto Changeover 17 Change filter 17 Replace batteries 18 Appendices Troubleshooting 19 Limited warranty 20 Table of contents 1 Turn Off Power to Heating Cooling System or M31535 Circuit breaker box Heating cooling system power switch ...

Page 4: ...inal designation If you have an older thermostat with a sealed mercury tube turn to page 2 for proper disposal instructions Terminal designation C C MCR31537 2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached 4 Separate Wallplate from New Thermostat Remove wallplate from the new thermostat and mount onto wall Wallplate M28073 ...

Page 5: ...ls do not match letters on the thermostat check Alternate Wiring Conventional Systems on page 6 and connect to terminal as shown here see notes below We are here to help Call 1 800 468 1502 for wiring assistance M28094 Remove metal jumper if you have both R and Rc wires MCR28845 W2 Y2 C G Y W RC R LABELED WIRES SCREW CONVENTIONAL INSERT WIRES THEN TIGHTEN SCREWS WIRE HOLE Y G R W CONVENTIONAL ...

Page 6: ...er Connect the R wire to the Rc terminal and the RH wire to the R terminal If your old thermostat had only 1 C or C1 wire connect it to the C terminal If your old thermostat had 2 C or C1 wires wrap each separately with electrical tape and do not connect them C G Y W RC R W2 Y2 Y2 W2 W Y G MCR32160 R 2 Rc 2 C 3 NOTE If E and Aux do not each have a wire connected use a small piece of wire to connec...

Page 7: ...eparate O and B wires attach the B wire to the C terminal If another wire is attached to the C terminal stop now and contact a qualified contractor for help If your old thermostat had Y1 W1 and W2 wires stop now and contact a qualified contractor for help If L terminal is used C terminal wire must be connected contact a contractor if there is no C wire If E and Aux terminals do not each have a wir...

Page 8: ...1544 or Circuit breaker box Heating cooling system power switch M28101 Back of thermostat Remove tab M28102 8 Install Thermostat onto Wallplate Install thermostat onto the wallplate on the wall 9 Turn Power Back On Turn the power back on to the heating cooling system M28103 ...

Page 9: ...nd Cool q Heat Pump without Backup Heat q Heat Pump with Backup Heat q Heat Only q Cool Only Continue with Advanced Installation on next page to match your thermostat to your system type Heat Pump an air conditioner that provides cooling in the summer and also runs in reverse in the winter to provide heating If you are not sure of your system type or if you have other questions call us toll free a...

Page 10: ... change the setting 2 Press NEXT to advance to next function 3 Press DONE to save exit Go Back Next Done 20 0120 Function Setting NOTE Some functions in the following pages may not appear due to previous selections made Function Description Setting Press the s or t button to change the setting 0120 Year Setting first two digits 20 Year 20xx 21 Year 21xx 0130 Year Setting second two digits 01 99 i ...

Page 11: ...s fan operation 0190 Heat Pump Changeover Valve for heat pumps only 0 Cooling changeover valve Use this setting if you connected a wire labeled O to the O B terminal see page 6 1 Heating changeover valve Use this setting if you connected a wire labeled B to the O B terminal see page 7 0240 Heating Cycle Rate 5 Gas or oil furnace Standard gas oil furnace less than 90 efficiency 9 Electric furnace E...

Page 12: ... 4 32 C 0610 Minimum Cool Setting 50 F other options 51 99 F 11 37 C 0640 Clock Format 1212 hour clock i e 3 30 pm 2424 hour clock i e 15 30 About your new thermostat Your new Honeywell thermostat has been designed to give you many years of reliable service and easy to use push button climate control Easy to follow menu programming One touch temp control overrides program schedule at any time Prec...

Page 13: ...press SYSTEM to select Heat Heating system control Cool Cooling system control Auto Thermostat automatically selects heating or cooling depending on the indoor temperature Off All systems off Em Heat Emergency Auxiliary Heat control Compressor is locked out Select models only System Status Cool On Cooling system is on Heat On Heating system is on Aux Heat On Auxiliary heating system is activated h...

Page 14: ...ning until bedtime Sleep Set to the time you go to bed and the temperature you want overnight usually an energy saving level NOTE Leave and Return periods can be canceled on weekends Heat Cool Wake 6 00 am 70 75 Leave 8 00 am 62 83 Return 6 00 pm 70 75 Sleep 10 00 pm 62 78 Clock setting 1 To set the current time display press CLOCK MORE then press s or t to adjust the time Press and hold s or t to...

Page 15: ...28085 Go Back Next Step Done Period Wake MON TUE WED THU FRI Set to Heat AM 62 6 00 MCR28086 To adjust program schedules RTH7500 RET97D only 1 Press SCHEDULE then EDIT to see weekdays 2 Press SELECT DAY You can select multiple days to program with the same settings 3 Press NEXT STEP twice then press s or t to set Wake time for selected day s 4 Press NEXT STEP then s or t to set Heat temperature fo...

Page 16: ...current time period To cancel the temporary setting at any time press USE SCHEDULE System Fan Use Schedule Clock More System Heat Fan Auto Mon Temporary Set to Heat On AM 62 68 6 08 MCR28087 Program schedule override permanent Press s or t to adjust temperature then press HOLD This will turn off the program schedule Whatever temperature you set will be maintained 24 hours a day until you manually ...

Page 17: ...etting the display will show an up arrow next to Cool to show the thermostat is raising the cool setting up to maintain a 3 degree separation The display will also show both Auto and either Heat or Cool for which temperature setting you are currently adjusting Press the system button to select between the heat and cool to view adjust either mode 69 System Hold Heat Cool Fan Auto Cancel Set To Tue ...

Page 18: ...used in climates where both air conditioning and heating are used on the same day When the system is set to Auto the thermostat automatically selects heating or cooling depending on the indoor temperature Heat and cool settings must be at least 3 degrees apart The thermostat will automatically adjust settings to maintain this 3 degree separation Turn thermostat over insert fresh AA alkaline batter...

Page 19: ...t 5 minutes for the system to respond Cannot change system setting to Cool Check Function 0170 System Type to make sure it is set to match your heating and cooling equipment Fan does not turn on when heat is required Check Function 0180 Heating Fan Control to make sure it is set to match your heating equipment Heating system is running in cool mode Check Function 0170 System Type to make sure it i...

Page 20: ...stallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQU...

Page 21: ...termostato viejo 2 Instale y conecte los cables de su nuevo termostato 3 Ajuste su nuevo termostato para que concuerde con su sistema de calefacción refrigeración Este termostato funciona prácticamente con todos los tipos de sistemas Está preconfigurado para el sistema más común Necesita ayuda Aquí estamos Llame al 1 800 468 1502 para obtener asistencia con el cableado antes de devolver el termost...

Page 22: ...mostatos con mercurio en Canadá consulte con Switch the Stat en www switchthestat ca NO MERCURY NO BOTE MERCURIO Hg Asistencia al cliente Para obtener asistencia relacionada con este producto visite http yourhome honeywell com O comuníquese con el número gratuito del servicio de atención al cliente llamando al 1 800 468 1502 Para ahorrar tiempo anote el número de modelo y el código de fecha antes ...

Page 23: ... 14 Ajuste de los cronogramas del programa 15 Anulación temporal de los cronogramas 16 Anulación permanente de los cronogramas 16 Conversión automática 17 Cambio del filtro 17 Reemplazo de la batería 18 Apéndices Localización y solución de problemas 19 Garantía limitada 20 Acerca 1 Desconecte la alimentación en el sistema de calefacción refrigeración o M31535 Caja de interruptores de circuito Inte...

Page 24: ...e un tubo de mercurio sellado vaya a la página 2 para obtener instrucciones sobre cómo desecharlo adecuadamente Rótulos para los cables Designación de los terminales C C MCR31537 2 Remueva su viejo termostato Retire el termostato existente pero deje la placa de montaje con los cables adheridos 4 Separe la placa de montaje del termostato nuevo Retire la placa de montaje del termostato nuevo y mónte...

Page 25: ...las letras del termostato revise Conexión alternativa sistemas convencionales en la página 6 y conecte al terminal como se indica refiérase a las notas que siguen El termostato no trabaja con bombas de calor con calor auxiliar de reserva Estamos aquí para ayudarle Llame al 1 800 468 1502 para asistencia con el cableado M28094 Retire el empalme metálico si tiene los cables R y Rc MS28070 W2 Y2 C G ...

Page 26: ...ía solamente 1 alambre C o C1 conéctelo con el terminal de C Si su viejo termóstato tenía 2 alambres C o C1 envuelva cada uno con la cinta eléctrica y no los conecte C G Y W RC R W2 Y2 Y2 W2 W Y G MCRS32160 R 2 Rc 2 C 3 Conexión alternativa bomba de calor Si los rótulos no coinciden con las letras de los terminales en el termostato consulte la página 7 MS28104 Aux E L C G Y O B RC R CABLES ETIQUET...

Page 27: ... una el alambre de B al terminal de C Si otro alambre se une al terminal de C ahora pare y entre en contacto con un contratista para la ayuda Si su viejo termóstato tenía alambres Y1 W1 y W2 ahora pare y entre en contacto con un contratista para la ayuda Si se utiliza L terminal el alambre terminal de C debe ser conectado entre en contacto con un contratista si no hay alambre de C Si E y los termi...

Page 28: ...termostato en la placa de montaje en la pared M31544 o Caja de interruptores de circuito Interruptor de energía del sistema de calefacción refrigeración M28101 Parte de atrás del termostato Retire la lengüeta M28102 M28103 9 Active nuevamente el suministro eléctrico Active nuevamente el suministro eléctrico del sistema de calefacción aire acondicionado ...

Page 29: ... y frío de etapas múltiples q Bomba de calor sin calor de respaldo q Bomba de calor con calor de respaldo q Solo calor q Solo frío Continúe con la instalación avanzada para adaptar el termostato a su tipo de sistema Bomba de calor un acondicionador de aire que proporciona enfriamiento en el verano y también funciona en reversa en el invierno proporcionando calor Si no está seguro del tipo de siste...

Page 30: ...os ajustes 2 Oprima NEXT para seleccionar la función 3 Oprima DONE para salir y guardar los ajustes Go Back Next Done 20 0120 Función Configuración NOTA Algunas funciones de las páginas siguientes puede que no aparezcan debido a las selecciones efectuadas previamente Función Descripción Configuración Oprima s o t para cambiar los ajustes 0120 Ajuste de año primeros dos dígitos 20 Año 20xx 21 Año 2...

Page 31: ...solamente 0 Válvula del cambio que se refrigeración Utilice este ajuste si usted conectó un alambre etiquetado O con el terminal de O B ver página 6 1 Válvula del cambio que se calefacción Utilice este ajuste si usted conectó un alambre etiquetado B con el terminal de O B ver página 7 0240 Frecuencia del ciclo de calefacción 5 Estufa normal a gas o petróleo que tiene una eficiencia menor al 90 9 E...

Page 32: ...nfriamiento 50 F otras opciones 51 a 99 F 11 a 37 C 0640 Formato del reloj 12Reloj 12 hour 3 30 pm 24Reloj 24 hour 15 30 Acerca de su nuevo termostato Su nuevo termostato ha sido diseñado para brindarle muchos años de funcionamiento confiable y para brindarle un control climático fácil de usar y con sólo apretar un botón Programación con menú fácil de seguir El control de temp de un sólo toque anu...

Page 33: ... encendido Heat On El sistema de calefacción está encendido Aux Heat On El sistema de calefacción auxiliar está activado bombas de calefacción solamente Ajuste de temperatura Hora actual Temperatura interior actual Smart Response Technology activado ver página 18 el botón FAN para seleccionar Auto El ventilador funciona solamente cuando la calefacción o el sistema de refrigeración están encendidos...

Page 34: ...mana Recomendamos estas configuraciones preestablecidas se muestran en el cuadro a continuación debido a que reducen los gastos de calefacción y refrigeración WAKE Programe la hora en que se despierta y la temperatura que quiere durante la mañana hasta que usted se va de su casa LEAVE Programe la hora en que usted se va de su casa y la temperatura que quiere mientras no esté en su casa por lo gene...

Page 35: ...los pasos 1 6 para programar Sab Dom Oprima s o t hasta que está destellando el día deseado después oprima SELECT DAY 8 Oprima DONE para guardar y salir System Fan Schedule Clock More MCR28084 Go Back Edit View MCR28085 Go Back Next Step Done Period Wake MON TUE WED THU FRI Set to Heat AM 62 6 00 MCR28086 1 Oprima SCHEDULE luego oprima EDIT 2 Oprima SELECT DAY Usted puede programar días múltiples ...

Page 36: ...ratura al nivel que haya programado para el período actual Para cancelar los ajustes temporarios en cualquier momento oprima USE SCHEDULE System Fan Use Schedule Clock More System Heat Fan Auto Mon Temporary Set to Heat On AM 62 68 6 08 MCR28087 Oprima s o t para ajustar temperatura luego oprima HOLD Esto apagará el horario de programas Cualquier temperatura que fije se mantendrá 24 horas al día h...

Page 37: ...e aire acondicionado la pantalla mostrará una flecha ascendente al lado de cool frío para mostrar que el termostato está elevando la configuración de frío para mantener una separación de 3 grados La pantalla también mostrará tanto Auto automático como Heat calor o Cool frío para la configuración de temperatura que está actualmente ajustando Presione el botón del sistema para elegir entre calor y e...

Page 38: ... prevenir daños Durante el tiempo de espera el mensaje Wait titila en la pantalla Cambio automático Cuando el sistema se fija en Auto el termostato selecciona automáticamente calefacción o refrigeración de acuerdo a la temperatura del interior Gire el termostato e inserte baterías AA alcalinas nuevas luego vuelva a instalar el termostato Reemplazo de la batería MCR28101 Las baterías son opcionales...

Page 39: ... del sistem No se puede cambiar el sistema a refrigeración Verifique la Función 170 Tipo de sistema para asegurarse de que esté ajustado para su sistema de refrigeración y calefacción El ventilador no se enciende al requerirse calefacción Verifique la Función 180 Control de ventilador de calefacción para asegurarse que esté ajustado para su equipo de calefacción El equipo de calefacción funciona e...

Page 40: ...licará si Honeywell demuestra que el defecto o mal funcionamiento estaba causado por daños ocurridos mientras el producto estaba en posesión de un consumidor La única responsabilidad de Honeywell será reparar o reemplazar el producto dentro de los plazos establecidos anteriormente HONEYWELL NO RESPONDERA POR LA PÉRDIDA O DAÑO DE NINGUN TIPO INCLUIDO EL DAÑO INCIDENTAL O INDIRECTO DERIVADO DIRECTA ...

Reviews: