RABO
®
Rotary Gas Meter
11 Elster Instromet
ACCESSORY
�����������
Problem
Probable Cause
Suggested Action
Excessive vibration
Build-up of foreign material on impellers
Clean by flushing, or replace worn parts
Misalignment
Level meter in piping
Worn bearings
Replace bearings
Worn timing gears
Replace timing gears
Impellers contacting body
Rotate manually to verify impellers spin freely
High differential pressure
Heavyweight or too much oil
Check oil level and condition
Dirt deposits on impellers
Remove dirt by flushing
Impellers out of time
Retime impellers
Impellers contacting body
Rotate manually to verify impellers spin freely
Low registration
Upstream or bypass leak
Check all valves for leakage
Non-registration
Broken or binding index odometer
Replace odometer
Obstruction in meter
Remove meter, remove obstructions, flush meter
15. Troubleshooting
Figure 19. Horizontal installation
14. Auxiliary Equipment Mounting
All RABO meters are equipped with threaded holes for mounting
compact, lightweight auxiliary equipment [Figures 19 and 20].
All holes are M6 x 1 by 10mm deep. Heavier equipment should
be pipe or wall mounted adjacent to the meter. Elster provides
customized brackets for commonly used equipment [Figure 21].
Please contact your local Elster representative for details.
NPT AUXILIARY PORTS
Figure 18. Auxiliary ports
Figure 20. Vertical installation
13. Thermowell
All RABO meters come equipped with two (2) ¼" NPT auxiliary
ports on the meter body [Figure 18], which can be used for sensing
pressure and temperature of the flowing gas. A thermowell is
required when using a temperature sensing device. Thermowells
are available as accessories to the meter.
a) Installing a Thermowell
1.
If meter is not installed in the gas piping, go to Step 5.
2. Slowly open bypass valve.
3. Slowly close the meter’s outlet valve, then the inlet valve.
4. Slowly, completely depressurize the meter piping.
5. Remove one of the plugs in the meter body by using a
¼" hex key.
6. Apply Teflon tape or pipe dope to the male threads of the
thermowell. Wipe excess pipe dope off the thermowell
probe and leading threads to ensure no pipe dope
enters the metering chamber.
7.
Screw the thermowell into the meter and tighten to
18 ft-lbs.
8. Re-pressurize the meter as instructed in Start-up/
Commissioning (see section 6).