Q314, Q324, Q327, Q350, Q377, Q379, Q380 AND Q382 PILOT BURNERS
60-2075—3
17
WARNING
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE, SEVERE
INJURY, OR DEATH
Follow these warnings exactly.
1.
Disconnect power supply before wiring to prevent
electrical shock or equipment damage.
2.
To avoid dangerous accumulation of fuel gas, turn
off gas supply at appliance service valve before
starting Installation and perform Gas Leak Test
after completion of Installation.
3.
Do not bend pilot tubing at the gas control or pilot
burner after compression nut has been tightened.
Gas leakage at the connection may result.
Follow appliance manufacturer’s instructions if available;
otherwise, use instructions provided below.
Location
1. Position the pilot burner for easy access, observation,
and lighting. In replacement applications, replace the
pilot burner with an identical unit and position the new
pilot burner in the same location and orientation as the
original pilot burner.
2. Mount the pilot burner on the main burner. Mounting
surfaces other than the main burner can shift, bend, or
warp as furnace expands and contracts while operating.
See Fig. 17.
3. Mount the pilot burner so the ignition flame remains
properly positioned with respect to the main burner
flame. See Fig. 18.
4. Supply the pilot flame with ample air free of combustion
products.
5. Do not impinge the pilot flame on adjacent parts. Do not
impinge the main burner flame on the pilot burner.
6. Do not expose the pilot flame to falling scale that could
impair the ignition of the main burner.
7. Do not expose the pilot burner to main burner rollout
while igniting or extinguishing.
8. Do not expose the pilot flame to drafts that push or pull
the pilot flame away from the thermocouple or
thermopile.
M11464
PILOT BURNER/GENERATOR
MUST BE RIGIDLY POSITIONED
RELATIVE TO MAIN BURNER.
PILOT BURNER/GENERATOR MUST BE RIGIDLY
POSITIONED RELATIVE TO MAIN BURNER.
Q377
Q382
Fig. 17. Mount pilot burner on main burner
(Q377 and Q382 shown).
NOTE:
Q380 is for horizontal mounting only. Mounting
bracket must remain vertical.