Honeywell PRO22IC Specifications Download Page 4

PRO-2200 Series Access Modules

O R D E R I N G    

HAS-PRO2200M-01-EN(0807)DS-LD
August 2007
© 2007 Honeywell International, Inc.

Honeywell Access Systems UK

Charles Avenue
Burgess Hill
West Sussex.
RH15 9UF
01444 251180
01444 871074
www.honeywell.com/security/uk

For more information: 

www.honeywell.com/security/uk

Order #

Description

PW-2200 Controllers
PRO22IC

PRO-2200 Intelligent Controller

PRO22R1

PRO-2200 Single Reader Module

PRO22R2

PRO-2200 Dual Reader Module

PRO22OUT

PRO-2200 Sixteen Relay Output Module

PRO22IN

PRO-2200 Sixteen Alarm Input Module

PRO22EN

PRO-2200 Network Interface Module

PRO-Series Enclosures
PRO22ENC1

(Wall-mount) Capacity: Nine modules. Power supply and battery not included

PRO22ENC2

(19" Rack-mount) Capacity: Nine modules. Power  supply and battery not included

PRO22ENC3

(Tile-mount) Capacity: Two modules. Power supply and battery included

PRO22ENC4

(Tile-mount) Capacity: One module (PRO22R1 only). Power supply and battery included

PRO22ENC5

(Cage only for custom enclosures) Capacity: Nine modules. Power supply and battery not included

Optional Accessories
PRO22DCC

Daisy Chain cable required for PRO22ENC1, PRO22ENC2 and PRO22ENC5

PRO22E1PS

4-Amp rack-mounted power supply with battery backup required for PRO22ENC1, PRO22ENC2 and PRO22ENC5

Hardwired Kits
PRO22E1IC

Includes: PRO22ENC1, PRO22IC, PRO22E1PS, PRO22BAT1 and PRO22DCC

PRO22E2IC

Includes: PRO22ENC2, PRO22IC, PRO22E1PS, PRO22BAT1 and PRO22DCC

Network Kits
PRO22E1EN

Includes: PRO22ENC1, PRO22IC, PRO22EN, PRO22E1PS, PRO22BAT1 and PRO22DCC

PRO22E2EN

Includes: PRO22ENC2, PRO22IC, PRO22EN, PRO22E1PS, PRO22BAT1 and PRO22DCC

C O M M O N   S P E C I F I C AT I O N S

Dimensions:

• Board: 

9.0" H x 5.5" W x 1.0" D / 228.6 mm H x 
139.7 mm W x 25.4 mm D

• PRO22ENC1:  13.9" H x 17" W x 9" D / 353 mm H x 431.8

mm W x 228.6 mm D

• PRO22ENC2:  13.9" H x 18.9" W x 9" D / 353 mm H x 

480.06 mm W x 228.6 mm D

• PRO22ENC3:  14" H x 16" W x 4" D / 355.6 mm H x 406.4

mm W x 102 mm D

• PRO22ENC4:  8.37" H x 7.63" W x 7.63 D / 212.8 mm H x

194 mm W x 194 mm D

• PRO22ENC5:  9.35" H x 16.85" W x 5.6" D / 237.4 mm H 

x 427.9 mm W x 142.2 mm D

Enclosures:

• PRO22ENC1 (Wall-mount) Capacity:

- Nine modules. Power supply and battery not included

• PRO22ENC2 (19" Rack-mount) Capacity:

- Nine modules. Power supply and battery not included

• PRO22ENC3 (Tile-mount) Capacity:

- Two modules. Power supply and battery included

• PRO22ENC4 (Tile-mount) Capacity:

- One module (PRO22R1 only) Power supply and battery 

included

• PRO22ENC5 (Cage only for custom enclosures) Capacity:

- Nine modules. Power supply and battery not included

Environment:

• Temperature: 0 to 70° C operational: -55 to 85° C storage
• Humidity: 0 to 95% RHNC

Wire Requirements:

• Power - twisted pair, 18 AWG
• RS-485 - 24 AWG, 4,000 ft. / 1,200 m max, two twisted

pairs with shield (120W, 23pF, Belden 9842 or equiv.)

• RS-232 - 24 AWG, 25 ft. / 7.6 m max.
• Alarm input - twisted pair, 30 ohms max.

Summary of Contents for PRO22IC

Page 1: ...ustom End Of Line EOL resistance value sensitivity range and timing parameter The PRO 2200 Series of access modules is designed to accommodate various mounting options Units can be mounted in a rack configuration PRO22ENC1 PRO22ENC2 and PRO22ENC5 when space is limited or in a tile mount configuration PRO22ENC3 The PRO22ENC1 is a wall mounted enclosure rack unit The PRO22ENC2 is a 19 inch rack moun...

Page 2: ... installation Alarm Inputs Four state alarm input circuits normally opened normally closed non supervised supervised w EOL Mounting Options Rack or tile mounting options available Programmable Sensitivity Alarm conditioning with programmable sensitivity and hold time ADA Compliant ADA compliant allowing expanded door times selectable per reader Multiple Reader States Selectable reader states inclu...

Page 3: ...non supervised supervised with standard 1K or custom end of line resistance 200 10K Line conditioning programmable sensitivity and hold time Output Control Properties Outputs may be assigned to door related functions or general purpose I O The 5A relay s are rated to handle the inductive loads of door locking devices The 1A relay is rated to handle dry circuit logic Configurable as standard energi...

Page 4: ...des PRO22ENC1 PRO22IC PRO22E1PS PRO22BAT1 and PRO22DCC PRO22E2IC Includes PRO22ENC2 PRO22IC PRO22E1PS PRO22BAT1 and PRO22DCC Network Kits PRO22E1EN Includes PRO22ENC1 PRO22IC PRO22EN PRO22E1PS PRO22BAT1 and PRO22DCC PRO22E2EN Includes PRO22ENC2 PRO22IC PRO22EN PRO22E1PS PRO22BAT1 and PRO22DCC C O M M O N S P E C I F I C AT I O N S Dimensions Board 9 0 H x 5 5 W x 1 0 D 228 6 mm H x 139 7 mm W x 25...

Reviews: