C O N F I G U R AT I O N

Anti-passback support

Anti-passback support – free pass and exempt flags, last
area accessed, last reader accessed and time/date of last
access

Modular Hardware

Modular hardware architecture provides flexibility and
expansion capabilities

Database

Large, local controller database allows access control
decisions to be made by controller in real time without the
need to communicate to the server

Scalable

Scalable architecture ensures optimal performance with a
seamless upgrade path to accommodate future growth
beyond its initial installation

Alarm Inputs

Four-state alarm input circuits - normally opened, normally
closed, non-supervised, supervised (w/EOL)

Mounting Options

Rack or tile mounting options available

Programmable Sensitivity

Alarm conditioning with programmable sensitivity and hold
time

ADA Compliant

ADA compliant allowing expanded door times selectable per
reader

Multiple Reader States

Selectable reader states include card and PIN, card or PIN,
card only, or PIN only

Auto Switching

Auto switching power supply allows 110 / 220 operation with
PROENC1

Customisable Modes

System off-line modes customizable per reader include facility
code access, locked (no access), and unlocked (full-access)

Multiple Reader Formats

Supports multiple reader and card formats for maximum
flexibility and security options

B E N E F I T S

2

www.honeywell.com/security/uk

Summary of Contents for PRO22IC

Page 1: ...ustom End Of Line EOL resistance value sensitivity range and timing parameter The PRO 2200 Series of access modules is designed to accommodate various mounting options Units can be mounted in a rack configuration PRO22ENC1 PRO22ENC2 and PRO22ENC5 when space is limited or in a tile mount configuration PRO22ENC3 The PRO22ENC1 is a wall mounted enclosure rack unit The PRO22ENC2 is a 19 inch rack moun...

Page 2: ... installation Alarm Inputs Four state alarm input circuits normally opened normally closed non supervised supervised w EOL Mounting Options Rack or tile mounting options available Programmable Sensitivity Alarm conditioning with programmable sensitivity and hold time ADA Compliant ADA compliant allowing expanded door times selectable per reader Multiple Reader States Selectable reader states inclu...

Page 3: ...non supervised supervised with standard 1K or custom end of line resistance 200 10K Line conditioning programmable sensitivity and hold time Output Control Properties Outputs may be assigned to door related functions or general purpose I O The 5A relay s are rated to handle the inductive loads of door locking devices The 1A relay is rated to handle dry circuit logic Configurable as standard energi...

Page 4: ...des PRO22ENC1 PRO22IC PRO22E1PS PRO22BAT1 and PRO22DCC PRO22E2IC Includes PRO22ENC2 PRO22IC PRO22E1PS PRO22BAT1 and PRO22DCC Network Kits PRO22E1EN Includes PRO22ENC1 PRO22IC PRO22EN PRO22E1PS PRO22BAT1 and PRO22DCC PRO22E2EN Includes PRO22ENC2 PRO22IC PRO22EN PRO22E1PS PRO22BAT1 and PRO22DCC C O M M O N S P E C I F I C AT I O N S Dimensions Board 9 0 H x 5 5 W x 1 0 D 228 6 mm H x 139 7 mm W x 25...

Reviews: