Operating Manual
34
69-2493EFS—01
In case of difficulty
If you have difficulty with your thermostat, please try the suggestions below. Most
problems can be corrected quickly and easily.
Screen is
blank
•
Check circuit breaker and reset if necessary.
•
Make sure power switch at heating & cooling system is on.
•
Make sure furnace door is closed securely.
Screen is
difficult to
read
•
To change the screen brightness or color, see backlight options in the Preferences menu
(see page 21).
•
At 2 am each day, Prestige thermostats change screen colors for an hour, to prevent burn-
in. Touch the screen at any time to restore pre-set screen colors.
Heating
or cooling
system does
not respond
•
Press
SYSTEM
to set system to Heat. Make sure the temperature is set higher than the
Inside temperature.
•
Press
SYSTEM
to set system to Cool. Make sure the temperature is set lower than the
Inside temperature.
•
Check circuit breaker and reset if necessary.
•
Make sure power switch at heating & cooling system is on.
•
Make sure furnace door is closed securely.
•
If “Waiting For Equipment” is displayed, the compressor protection timer is on. Wait 5
minutes for the system to restart safely, without damaging the compressor.