background image

PLS750C/PLS751C

                                              1/8

PLS750C/PLS751C

User guide

7-day Solar Programmable Wall Switch

The PLS750C/PLS751C programmable wall switch has been designed to control lights and motors:

Cut power at the circuit breaker to avoid electric shock.

Remove the existing switch. (For a 3-way installation, identify and label the wire that is connected to 
the “common” screw.)

Install the new switch (see the appropriate section below).

Apply power at the circuit breaker.

SINGLE-SWITCH INSTALLATION

EXISTING 3-WAY INSTALLATION

Connect the LOAD wire on the PLS750C/PLS751C to the “common” wire, which you identified when
removing the old switch. Connect the NEUTRAL wire to the neutral (white) wires. Connect the LINE and 3-
WAY wires to the two remaining wires. At the other 3-way switch, connect the jumper wire between the
“common” screw and the screw where the LINE wire of the PLS750C/PLS751C is connected.

NOTE

: If the timer screen does not turn on when you apply power at the circuit break (step 4), cut the power

at the circuit breaker again, switch the blue (LOAD) and the black (LINE) wires and reapply power.

NEW 3-WAY INSTALLATION

The switch will turn the lights on at sunset and turn them off at 11:00 pm by default. If these settings are
appropriate for you, you only need to set the time and date (see shaded zone in the menu flowchart sheet).
If the switch’s sunset time does not correspond to the actual sunset time, see sections 5.3.3 and 5.3.4.

5.1

Mode Menu

You can use the Mode menu to select one of the three modes of operation (see sections 5.1.1 to 5.1.3).

5.1.1 Manual Mode 

In Manual mode, the switch operates like a regular switch. To turn the lights on or off,
briefly press the main button. The   icon appears when the switch is in Manual mode.

5.1.2 Automatic Mode 

In Automatic mode, the switch turns the lights on or off according to the set programs (see
Section 5.4). The 

 icon as well as the current program number are displayed.

5.1.3 Random Mode 

In Random mode, the switch has no specific times to turn the lights on or off. This mode is
designed to give the impression the house is occupied during your absence. It is similar to the
Automatic mode except there is no fixed program. The programs are automatically set to different
times by the switch every day. The 

 icon appears when the switch is in Random mode.

The first “On” program occurs at sunset. Each “On” program lasts between 1 hour and 1
hour and 30 minutes; each “Off” program lasts between 15 and 30 minutes. The last “Off”
program occurs between 10:30 pm and midnight.

5.1.4 Temporary Override

When the switch is in Automatic or Random mode, you can press the main button at any time to override the
default state for the current program. The lights will turn off if they are on and vice versa. The icon (On or Off)
of the new state flashes to indicate that the state is temporary. The new state is maintained until you press
the main button again or till the next “On” or “Off” program.

5.2

Time Menu

The time display flashes on the screen when the time has not yet been set or after a 4-hour power outage.
Use the Time menu to select the time format (12-hour or 24-hour) and to set the clock and date.

NOTE

: The date is used to determine the sunset and sunrise times.

Applications

1.

Load types

Maximum load

Examples

Lights and resistive loads 
(except tungsten)

1800 W (15 A @ 120 V)

fluorescent lights

compact fluorescent lights (CFL)

electronic ballasts

sodium lamps

block heaters

Tungsten lights

1440 W (12 A @ 120 V)

incandescent lights

halogen lights

Motors

1 hp

pool filter pumps

fans

Installation

2.

black (LINE)

yellow (3-WAY)

120
VAC

blue (LOAD)

white (NEUTRAL)

black

white

black

white

120 VAC

red

jumper

black

white

black (LINE)

yellow (3-WAY)

blue (LOAD)

white (NEUTRAL)

black

white

black

white

three-way
switch

120
VAC

black

white

black

white

black

white

black (LINE)

yellow (3 WAY)

blue (LOAD)

white (NEUTRAL)

single-pole
switch

Quick Start-up

3.

Set the time and date before using the timer for the first time.

Operation

4.

Setup Menus

5.

Press the main button for 3 seconds to enter the setup menus. Refer to 
the menu flowchart sheet on how to navigate the menus.

The   icon indicates the current 
program has been activated at sunset.
The 

 icon indicates the current 

program has been activated at sunrise.

The LED illuminates when the load 
state is on.

Briefly press this button to turn the 
lights on or off. See “Temporary 
Override” in Section 5.1.4.

Press for 3 seconds to enter the 
setup menus.

Indicates the mode of operation 
(see Section 5.1)

Indicates the current program

Indicates the load on/off state

Indicates the time and day

Indicates the keypad is locked 
(see Section 6)

Press this button to display today’s sunrise time.
Press this button to display today’s sunset time.

(3 sec.) 

NOTE:

This switch cannot be used if there is no neutral wire 
(white wires joint together) inside the electrical box.

69-2504EFS-03 (TI072-3W Honeywell PLS750C_PLS751C).book  Page 1  Thursday, September 15, 2011  3:49 PM

Summary of Contents for PLS750C

Page 1: ...lasts between 1 hour and 1 hour and 30 minutes each Off program lasts between 15 and 30 minutes The last Off program occurs between 10 30 pm and midnight 5 1 4 Temporary Override When the switch is in Automatic or Random mode you can press the main button at any time to override the default state for the current program The lights will turn off if they are on and vice versa The icon On or Off of t...

Page 2: ...dden until the next program starts If you press the main button again before the start of the next program the lights return to their initial state To lock or unlock the keypad press the buttons in the following order NOTE You must perform the whole procedure in an interval of 2 seconds If the procedure was not properly performed wait another 2 seconds before retrying To return the switch to its d...

Page 3: ...et 30 minutes Le dernier programme Arrêt se produit entre 22h30 et minuit 5 1 4 Dérogation temporaire Lorsque l interrupteur est en mode Automatique ou Aléatoire vous pouvez en tout temps appuyer sur la touche principale pour déroger à l état en cours les lumières s éteindront si elles sont allumées et vice versa L icône On ou Off du nouvel état clignote pour indiquer que l état est temporaire Le ...

Page 4: ... jusqu au début du programme suivant Si vous appuyez sur la touche principale de nouveau avant le début du prochain programme les lumières retourneront à leur état initial Pour verrouiller ou déverrouiller les réglages appuyer sur les touches dans l ordre suivant NOTA Vous devez exécuter la procédure dans une intervalle de 2 secondes Si la procédure n a pas été correctement exécutée attendre 2 aut...

Page 5: ... 15 y 30 minutos El último programa Apagado se produce entre las 22 30 y medianoche 5 1 4 Cancelación temporaria Cuando el interruptor está en modo Automático o Aleatorio se puede presionar el botón principal en cualquier momento para cancelar el estado en curso las luces se apagarán si estaban encendidas y viceversa El ícono On u Off del nuevo estado parpadea para indicar que es temporario El nue...

Page 6: ...bargo en modo Automático el estado quedará cancelado hasta el inicio del próximo programa Si se presiona nuevamente el botón principal antes del inicio del próximo programa las luces volverán a su estado inicial Para bloquear o desbloquear los ajustes presionar los botones en el orden siguiente NOTA la operación debe realizarse dentro de un intervalo de 2 segundos Si no se logró bloquear los ajust...

Page 7: ...outon pour accepter le réglage et afficher le prochain paramètre Presionar brevemente este botón para aceptar el ajuste y visualizar el parámetro siguiente Backlight Rétroéclairage Retroiluminación sec 5 3 1 3 sec Minutes setting Réglages des minutes Ajuste de los minutos or ou Offset setting Réglage de l écart Ajuste de la desviación None selected Nul None sélectionné Ninguno None seleccionado Da...

Page 8: ...OS ANGELES 34 118 0 LOUISVILLE 38 85 1 LUBBOCK 33 101 1 MACON 32 83 1 MADISON 43 89 0 MEMPHIS 35 90 0 MIAMI 25 80 0 MILWAUKEE 43 87 0 MINNEAPOLIS 44 93 0 MOBILE 30 88 0 MODESTO 37 120 0 MONTGOMERY 32 86 0 NASHVILLE 36 86 0 NEW ORLEANS 29 90 0 NEW YORK 40 74 0 NORFOLK 36 76 0 OKLAHOMA CITY 35 97 0 OMAHA 41 95 0 ORLANDO 28 81 0 OVERLAND PARK 38 94 0 OXNARD 34 119 0 PEORIA 40 89 0 PHILADELPHIA 40 75 ...