FunCTIon TabLe

Input assignment

Input

(I=Input)

Input function

output function

output

(O=Output)

output assignment / room

I0

Button local UP 

Motor M0 UP 

O1

I1

Button local DOWN 

Motor M0 DOWN 

O0

I2

Button local UP 

Motor M1 UP 

O3

I3

Button local DOWN 

Motor M1 DOWN 

O2

I4

Button local UP 

Motor M2 UP 

O5

I5

Button local DOWN 

Motor M2 DOWN 

O4

I6

Button local UP 

Motor M3 UP 

O7

I7

Button local DOWN 

Motor M3 DOWN 

O6

I8

Button local UP 

Motor M4 UP 

O9

I9

Button local DOWN 

Motor M4 DOWN 

O8

I10

Button local UP 

Motor M5 UP 

O11

I11

Button local DOWN 

Motor M5 DOWN 

O10

I12

Button local UP 

Motor M6 UP 

O13

I13

Button local DOWN 

Motor M6 DOWN 

O12

I14

Button local UP 

Motor M7 UP 

O15

I15

Button local DOWN 

Motor M7 DOWN 

O14

I16

Button local UP 

Motor M8 UP 

O17

I17

Button local DOWN 

Motor M8 DOWN 

O16

I18

Button local UP 

Motor M9 UP 

O19

I19

Button local DOWN 

Motor M9 DOWN 

O18

I20

Button local UP 

Motor M10 UP 

O21

I21

Button local DOWN 

Motor M10 DOWN 

O20

I22

Button local UP 

Motor M11 UP 

O23

I23

Button local DOWN 

Motor M11 DOWN 

O22

I24

Button central UP 

Central UP 

o

auF

I25

Button central DOWN 

Central DOWN 

o

AB

I26

Button group 0 UP 

Group 0 UP 

o

g0

I27

Button group 0 DOWN 

Group 0 DOWN 

I28

Button group 1 UP 

Group 1 UP 

o

g1

I29

Button group 1 DOWN 

Group 1 DOWN 

I30

(1)

 Button group 2 UP 

Group 2 UP 

o

g2

I31

(1)

 Button group 2 DOWN 

Group 2 DOWN 

I30

(2) 

Sun sensor S2 On/Off

Motor DOWN 

 / UP 

(Sun sensor S2 / S3)

o

ss

I31

(2) 

Sun sensor S3 On/Off

I32

(3)

 Automatic switch 

On/Off

Automatic (timer, Sun sensor, 

Twilight sensor)

o

u

 , 

o

ss

 , 

o

ds

I33

Twilight sensor

On/Off

Motor DOWN 

 / UP 

(Twilight sensor)

o

ds

I34

Sun sensor S1

On/Off

Motor DOWN 

 / UP 

(Sun sensor S1)

o

ss

I35

Wind-/ rain sensor

On/Off

Motor UP 

(Wind-/ rain sensor)

o

Ws

(1)

  Standard function of Group 2 (Group 2 mode “Standard”)

(2)

  Sun sensor S2/S3 when Group 2 set to “Sensors” mode (see CONFIGURING GROUP 2 instructions).

(3)

  Auto mode (timer, sun sensor, twilight sensor) for all assigned outputs (see AUTO MODE instructions).

o

auF

 

  All outputs UP

 

  

o

u

 

  Outputs with programmed timers

o

AB

 

  All outputs DOWN

 

  

o

ds

 

  Outputs with assigned twilight sensor

o

g0

 

  Group 0 outputs  

o

ss

 

  Outputs with assigned sun sensor

o

g1

 

  Group 1 outputs  

o

Ws

 

  Outputs with assigned wind-/ rain sensor

o

g2

 

  Group 2 outputs

ConneCTIng sensoRs

Sensors  connected  to  the  JRM  can  be  assigned  singly  to  every  output 

(motor) (see AUTO MODE and SENSORS instructions). The outputs (mo-

tors) can therefore be controlled depending on the daylight and weather.

WInD sensoR 940 Ws

The  940  WS  wind  sensor  with  the  940  WS-AE  plotting  unit  is  used  to 

protect electric motor operated blinds and awnings in combination with 

the JRM Module. The plotting unit requires an operating voltage of 24V 

DC. Output 15 of the plotting unit can be connected to the I35 24V input 

of the JRM Module:

A2

18

15

16

S2

S1

B2

B1

EIN

STÖRUNG

WINDSTÄRKE

9

10

3

4

5

6

7

8

18

15

S1

S2

16

24V

0V

940 WS-AE

0V

Compact 952 JRM

Input I35

Compact 952 JRM

sensor connection 24V

Attention!

 

The operating instructions for the wind sensor must be observed!

RaIn sensoR 940 Rs

The 940 RS rain sensor has a relay contact (COM u. N. O) to operate an 

input signal up to a maximum 50V DC / 0.5A. The device is provided with 

a heater for faster drying and snow recognition. The rain sensor requires 

an operating voltage of 24V DC and is particularly suitable for connecting 

to the JRM. 
You can connect the rain sensor parallel to a wind sensor (e.g. 940 WS) 

using the I35 24V input:

N.O

COM

N.C

VCC

GND

24V

0V

940 RS

Compact 952 JRM

sensor connection 24V

0V

Input I35

Compact 952 JRM

Attention!

 

The operating instructions for the rain sensor must be observed!

TWILIghT / sun sensoR 941 LuX

The 941 LUX twilight/sun sensor consists of the 941 LUX-LF light sensor 

and the 941 LUX-REG evaluation unit.

A10

A11

twilight sensor

Switching off threshold

Hysterisis

Switching on threshold

B

rightness

 

941 LuX-Reg

The twilight sensor is connected to the 

24V input I33 on the JRM.

A10

A11

sonnensensor

Ausschaltschwelle

Hysterese

Einschaltschwelle

B

eleuchtungs-

stärk

e

941 LuX-LF

The S1 sun sensor is connected to the 24V input I34 on the JRM. When 

Group 2 has been set to “Sensors”, a sun sensor (S2/S3) can optionally 

be connected to the inputs I30 and I31.

 

This allows the level of brightness 

(sun from the east, south and west) to be captured correctly.

941 LUX-REG

S2

S1

S3

B2

B1

A10

A11

0V

24V

Light sensor

941 LUX-LF

Parallel connection of

several 941 LUX-REG

Compact 952 JRM

sensor connection 24V

952 JRM

Input I 34

952 JRM

Input I 33

Attention!

 The operating instructions for the twilight/sun sensor 

must be observed!

Summary of Contents for PEHA 952 JRM

Page 1: ...gssensor I33 7 Automatik 24V Eingang zum Anschluss eines Schalters zur Aktivierung Deaktivierung der Automatik I32 8 Tastbetrieb Gruppe 24V Eingänge zum Anschluss von 3 Doppeltastern für die AUF AB Funktion der Gruppe 0 bis 2 Achtung Bei der Einstellung Sensoren ist die Gruppe 2 deaktiviert Der Eingang I30 und I31 der Gruppe 2 steht dann zum Anschluss eines Sonnensensors S2 S3 zur Verfügung I26 I3...

Page 2: ...zugeordneten Wind Regensensor OG2 Ausgänge der Gruppe 2 Anschluss von Sensoren An das JRM angeschlossene Sensoren können jedem Ausgang Motor einzeln zugeordnet werden s Anleitung AUTOMATIK u SENSORIK Damit kann die Ansteuerung der Ausgänge Motoren in Abhängigkeit vom Tageslicht und Wetter erfolgen Windsensor 940 WS Der Windsensor 940 WS mit der Auswerteeinheit 940 WS AE wird zum Windschutz von ele...

Page 3: ... activate deactivate auto mode I32 8 Pushbutton mode Group 24V inputs for connecting 3 dual buttons for the UP DOWN function in group 0 2 Attention The Sensors setting deactivates Group 2 The inputs I30 and I31 for Group 2 are then available for connection to a sun sensor S2 S3 I26 I31 9 Pushbutton mode Central 24V inputs for connection of 1 double button for the central UP DOWN function I24 I25 1...

Page 4: ...Outputs with assigned wind rain sensor OG2 Group 2 outputs Connecting sensors Sensors connected to the JRM can be assigned singly to every output motor see AUTO MODE and SENSORS instructions The outputs mo tors can therefore be controlled depending on the daylight and weather Wind sensor 940 WS The 940 WS wind sensor with the 940 WS AE plotting unit is used to protect electric motor operated blind...

Page 5: ...sch 24 V ingang voor de aansluiting van een schakelaar voor de activering deactivering van het automatische bedrijf I32 8 Toetsbediening Groep 24V ingangen voor de aansluiting van 3 dubbele druktoets voor de OP NEER functie van groep 0 2 Let op Bij de instelling Sensoren is groep 2 gedeactiveerd De ingangen I30 en I31 van groep 2 zijn dan beschikbaar voor de aansluiting van een zonnesensor S2 S3 I...

Page 6: ...nsensor OG2 Uitgangen van groep 2 De sensoren aansluiten Op de JRM aangesloten sensoren kunnen aan elke uitgang motor af zonderlijk worden toegewezen zie handleiding AUTOMATISCH en SEN SOREN Daarmee kan de aansturing van de uitgangen motoren af hankelijk van het daglicht en het weer plaatsvinden Windsensor 940 WS De windsensor 940 WS met de analyse eenheid 940 WS AE wordt vooral gebruikt ter besch...

Page 7: ... crépusculaire I33 7 Mode automatique Entrée 24 V pour raccorder un interrupteur d activation de désactivation du mode automatique I32 8 Mode touche Groupe Entrées de 24 V pour raccorder trois boutons poussoirs doubles pour la fonction Haut BAS des groupes 0 à 2 Attention En cas de réglage en mode Capteurs le groupe 2 est désactivé Les entrées I30 et I31 du groupe 2 sont alors disponibles pour le ...

Page 8: ...rties du groupe 1 OWS Sorties avec le Capteur de vent de pluie affecté OG2 Sorties du groupe 2 Raccordement des capteurs Les capteurs raccordés au module JRM peuvent être affectés séparément à chaque sortie moteur voir le mode d emploi AUTOMATIQUE et CAP TEURS Il est donc possible de commander les sorties moteurs en fon ction de la lumière du jour et des conditions météorologiques Capteur de vent ...

Reviews: