4. If you wish to connect a remote control device, insert the 

wires (use 18- to 22-gauge flexible wires) through one of 

the two openings on the base and connect them to ter-

minals 2 and 3 (no polarity).

5. Push the excess length of the high-voltage wires back 

inside the electrical box.

6. Secure the power base to the electrical box using the 

provided screws.

Installing the Control Module (faceplate)

1. Verify the settings of the configuration switches (if any) 

on the back of the faceplate (see user guide).

2. Install the control module (faceplate) on the power base 

(see user guide).

3. Apply power to the heating system. Verify the installa-

tion by making sure that the heating system can be 

turned on and turned off by increasing and decreasing 

the setpoint.

4. Test the ground fault protection.

Testing the Ground Fault Protection

To ensure the ground fault protection is always in working
order, test it once the thermostat is installed and on a monthly
basis thereafter.

1. Increase the setpoint temperature above the measured 

temperature in order to activate the heating system.

2. Press the TEST button.

• If the TEST light does NOT come on, the test has 

failed. Cut power to the heating system at the main 

electrical panel, have an electrician verify the 

installation and, if necessary, replace the thermostat.

• If the TEST light comes on, continue the test.

3. Switch the thermostat to Standby then back to On.

• If the TEST light goes off, the test has passed. Set the 

thermostat back to the desired temperature. The test 

is now completed.

• If the TEST light remains on, the test has failed. 

Continue with the rest of the procedure.

4. Switch the circuit breaker (at the service panel) of the 

heating system to off then back to on.

5. Repeat the test. If the test fails again, cut power to the 

heating system at the main electrical panel, have an 

electrician verify the installation and, if necessary, 

replace the thermostat.

Technical Specifications

Heating cycle length:  15 minutes

Operating temperature:  0°C to 50°C (32°F to 122°F)

Storage temperature:  -20 °C to 50 °C (-4 °F to 120 °F)

Size (H • W • D):  124 x 70 x 23 mm (4.89 x 2.76 x 0.91 in.)

Warranty

Honeywell warrants this product, excluding battery, to be free from defects in the workman-
ship or materials, under normal use and service, for a period of one (1) year from the date of
purchase by the consumer. If at any time during the warranty period the product is deter-
mined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's
option).
If the product is defective,

(i) return it, with a bill of sale or other dated proof of purchase, to the place from which

you purchased it, or 

(ii) contact Honeywell. Honeywell will make the determination whether the product should

be returned, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it
is shown by Honeywell that the defect or malfunction was caused by damage which occurred
while the product was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the product within the terms
stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR
IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces, states or
regions do not allow the exclusion or limitation of incidental or consequential damages, so
this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some provinces,
states or regions do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from
one province, state or region to another.
If you have any questions about the product, contact us at:
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel: 1-800-831-2823
E-mail: [email protected]

If your thermostat has the Vacation Mode, the mode can be 

activated from an Aube telephone controller (CT240 or 

CT241) or any other remote control device equipped with a 

normally open (NO) dry contact. For more information on 

this mode, see the thermostat’s user guide.

Floor 

temperature 

sensor

TEST button/light

Supply

Maximum Load

(resistive only)

Wiring

Current

Power

120 VAC, 50/60Hz 15 A

1800 W 4 wires, double pole

240 VAC, 50/60Hz 15 A

3600 W 4 wires, double pole

Model

Ground Fault Protection

Current Leakage Limit

GA

Ground Fault Circuit 

Interrupter (GFCI), class A

5 mA

GB

Equipment Ground Fault 

Protection Device (EGFPD)

15 mA

Summary of Contents for PB112C-GA

Page 1: ...against circuit overloads short circuits or electrical shocks For example you can still receive an electrical shock if you touch bare wires while standing on a non conducting surface such as a wood floor Ground Fault Protection Reset When the ground fault protection mechanism trips the TEST light is On red To reset the ground fault protection switch the thermostat to Standby and back to On The TES...

Page 2: ...ship or materials under normal use and service for a period of one 1 year from the date of purchase by the consumer If at any time during the warranty period the product is deter mined to be defective or malfunctions Honeywell shall repair or replace it at Honeywell s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you pur...

Page 3: ...rts circuits ou les chocs Par exemple vous pouvez toujours ressentir un choc si vous touchez des fils dénudés en vous tenant sur une surface non conductrice comme un plancher de bois Réinitialisation de la protection contre les fuites à la terre Lorsque le dispositif de protection de fuite à la terre se déclenche le témoin TEST s allumera rouge Pour réinitialiser la protection contre les fuites à ...

Page 4: ...ir de la date d achat par le consommateur En cas de défectuosité ou de mau vais fonctionnement pendant la période de garantie Honeywell remplacera ou réparera le produit au gré de Honeywell Si le produit est défectueux i le retourner accompagné d une preuve d achat indiquant la date d achat à l endroit où il a été acheté ou ii contacter Honeywell Honeywell déterminera alors si le produit doit être...

Reviews: