Honeywell NOTIFIER XP10-M Installation And Maintenance Instructions Download Page 4

N500-77-00  4 I56-1803-010 
 

 

©2014 Notifier

0

1

2

3

4

5 6

7 8 9

BASE ADDRESS

TO NEXT

DEVICE

STATUS

INDICATORS

   

  +

   

  +

   

  +

   

  +

   

  +

   

  +

IDC

ADDRESS

+0

+1

+2

+3

+4

+5

+6

+7

+8

+9

IDC

ADDRESS

IDC

ADDRESS

IDC

ADDRESS

IDC

ADDRESS

   

  +

   

  +

SLC

   

  +

   

  +

+

+

FROM PANEL OR

PREVIOUS DEVICE

47K

EOL

RESISTOR

ELR-47K

CONNECT MODULES TO

LISTED COMPATIBLE

NOTIFIER CONTROL

PANELS ONLY

COMMUNICATION LINE 32 VDC MAX.

SEE PANEL INSTRUCTION MANUAL

FOR WIRE REQUIREMENTS.

CLASS B IDC (TYPICAL)

   

  +

   

  +

A/B SLCT

COM LOSS

DISABLE 1

DISABLE 2

0

1

2

3

4

5 6

7 8 9

10

11

12

13

14

15

POWER LIMITED

AND SUPERVISED

NOTE: Any number of UL listed contact closure devices may be used. DO NOT mix fire alarm initiating and supervisory devices on the same initiating device 
circuit. Install contact closure devices per manufacturer’s installation instructions.

NOTE: Any number of UL listed contact closure devices may be used. DO NOT mix fire alarm initiating and supervisory devices on the same initiating device 
circuit. Install contact closure devices per manufacturer’s installation instructions.

BASE ADDRESS

TO NEXT

DEVICE

STATUS

INDICATORS

   

  +

   

  +

   

  +

   

  +

   

  +

   

  +

IDC

ADDRESS

+0

+1

+2

+3

+4

+5

+6

+7

+8

+9

IDC

ADDRESS

IDC

ADDRESS

IDC

ADDRESS

IDC

ADDRESS

   

  +

   

  +

SLC

   

  +

   

  +

+

+

FROM PANEL OR

PREVIOUS DEVICE

CONNECT MODULES TO

LISTED COMPATIBLE

NOTIFIER CONTROL

PANELS ONLY

COMMUNICATION LINE 32 VDC MAX.

SEE PANEL INSTRUCTION MANUAL

FOR WIRE REQUIREMENTS.

CLASS A IDC (TYPICAL)

   

  +

   

  +

A/B SLCT

COM LOSS

DISABLE 1

DISABLE 2

IDC 2

IDC 3

IDC 4

IDC 5

0

1

2

3

4

5 6

7 8 9

0

1

2

3

4

5 6

7 8 9

10

11

12

13

14

15

POWER LIMITED

AND SUPERVISED

REMOVE SHUNT FOR CLASS A.

FIGURE 8. TYPICAL INITIATING DEVICE CIRCUIT CONFIGURATION – CLASS B, STYLE B:

FIGURE 9. TYPICAL FAULT TOLERANT INITIATING DEVICE CIRCUIT CONFIGURATION – CLASS A, STYLE D:

C0252-00

C0251-00

Summary of Contents for NOTIFIER XP10-M

Page 1: ...ules This system contains static sensitive components Always ground yourself with a proper wrist strap before handling any circuits so that static charges are re moved from the body The housing cabinet should be metallic and suitably grounded NOTICE This manual should be left with the owner user of this equipment GENERAL DESCRIPTION The XP10 M Ten Input Monitor Module is intended for use in an int...

Page 2: ... will be installed in the chassis position in front of it Refer to Figures 6a and 6b for method two All necessary screws and standoffs are supplied with the modules FIGURE 5 INSTALLATION OF REAR MODULE ONLY METHOD ONE Step 1 Insert the bottom of the XP10 M module down into a rear slot on the chassis Step 2 Carefully swing the upper edge of the board back towards the back of the chassis until it to...

Page 3: ...at may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordanc...

Page 4: ...lation instructions NOTE Any number of UL listed contact closure devices may be used DO NOT mix fire alarm initiating and supervisory devices on the same initiating device circuit Install contact closure devices per manufacturer s installation instructions BASE ADDRESS TO NEXT DEVICE STATUS INDICATORS IDC ADDRESS 0 1 2 3 4 5 6 7 8 9 IDC ADDRESS IDC ADDRESS IDC ADDRESS IDC ADDRESS SLC FROM PANEL OR...

Reviews: