background image

Cable Installation and Removal   

Installation   

1. Insert the cable’s modular connector into the socket on the 
    scanner.   

 

2. Pull gently on the cable strain relief to ensure the cable is 
    installed.   

 

Note: If the PowerLink cable is not fully latched, the unit can 
          power    intermittently.   

Figure 3.

 

Removal 

Disconnect the power supply from the PowerLink cable and turn 
off power to the host system before removing the cable from the   
scanner.   

 

1. Locate the small ’pin-hole’ on the 
    front side of the scanner near the   
    end of the handle.   
 
2. Bend an ordinary paperclip into the   
    shape shown.   
 
3. Insert the paperclip (or other small   
    metallic pin) into the small ’pin-hole’.   
    There will be a faint ’click’ when the   
    connector’s lock releases.   
 
4. Pull gently on the cable’s strain-relief   

    to remove the cable.

 

                                                                                                            Figure 4.   

 

Summary of Contents for MS5145 - 00

Page 1: ...r beam pulses making lining up bar codes easy and when the scanner senses a bar code CodeSense Mode the laser beam automatically switches to scan mode and activates CodeGate to ensure high speed scanning and accuracy Many standard features are included such as user configurable Flash ROM PowerLink user replaceable cables MetroSet 2 and MetroSelect configuration and data editing parsing Model Numbe...

Page 2: ...r Components Maintenance Smudges and dirt on the unit s window can interfere with the unit s performance If the window requires cleaning use only a mild glass cleaner containing no ammonia When cleaning the window spray the cleaner onto a lint free non abrasive cleaning cloth then gently wipe the window clean If the unit s case requires cleaning use a mild cleaning agent that does not contain stro...

Page 3: ...ith applicable standards all circuits connected to the imager must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC 60950 1 To maintain compliance with standard CSA C22 2 No 60950 1 UL 60950 1 and norm EN IEC 60950 1 the power source should meet applicable performance requirements for a limited power source ...

Page 4: ...oval Disconnect the power supply from the PowerLink cable and turn off power to the host system before removing the cable from the scanner 1 Locate the small pin hole on the front side of the scanner near the end of the handle 2 Bend an ordinary paperclip into the shape shown 3 Insert the paperclip or other small metallic pin into the small pin hole There will be a faint click when the connector s...

Page 5: ...l port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration settings are also required for proper communications to occur Powering the MS5145 directly from the host device can sometimes cause interference with the operation of the scanner or the computer Not all computers supply the same current For this reason using an external po...

Page 6: ...eck the AC input require ments of the power supply to make sure the voltage Figure 7 Keyboard Wedge matches the AC outlet The outlet must be located near the equipment 7 Connect AC power to the transformer 8 Turn on the host system Installation Note Powering the MS5145 47 directly from the computer can sometimes cause interference with the operation of the scanner or the computer Not all computers...

Page 7: ...let The outlet should be near the equipment and easily accessible 5 Connect the PowerLink cable to the keyboard port on the host system 6 Turn on the host system Figure 8 Stand Alone Keyboard Installation Note Powering the MS5145 47 directly from the computer can sometimes cause interference with the operation of the scanner or the computer Not all computers supply the same current through the key...

Page 8: ...ation on configuring the MS5145 38 for USB Serial Emulation Mode please refer to the USB section of the MetroSelect Single Line Configuration Guide Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system All Eclipse s are shipped already configured with a set of factory defaults Please refer to the MetroSelect...

Page 9: ...vates when removed from the stand Bar code data is transmitted when the button is pressed Manual Activation Mode Out of Stand Button activates laser Bar code data is scanned and transmitted while button is held down Figure 10 CodeGate Enabled Figure 11 Manual Activation Mode ...

Page 10: ...10 Depth of Field by Bar Code Element Width ...

Page 11: ...g but is not receiving the signal If the unit is setup to support ACK NAK RTS CTS XON XOFF or D E verify that the host cable and host are supporting the handshaking properly The unit scans but the data transmitted to the host is incorrect The unit s data format does not match the host system s requirements Verify the unit s data format matches that required by the host Make sure that the unit is c...

Page 12: ...wer up the unit beeps two times and alternately flashes the LEDs There is a ROM failure A flash ROM upgrade is required At power up the unit beeps three times There is a non volatile RAM failure At power up there is a continuous razz tone There has been a diagnostic failure At power up there is a razz tone and the green LED flashes There is a VLD failure At power up there is a razz tone and both L...

Page 13: ...ot be supported by that country s key look up table Try operating the scanner in Alt mode RS232 Interface The com port at the host is not working or not configured properly Check to make sure the baud rate and parity of the scanner and the port match and that the configuration is looking for RS232 data The unit powers up OK and scans OK but does not communicate properly to the host The cable is no...

Page 14: ...escáner para examinar el aparato El hacerlo puede conllevar una exposición peligrosa a la luz de láser El uso de instrumentos ópticos con el equipo láser puede incrementar el riesgo para la vista Attention L emploi de commandes réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations Le client ne doit en aucun cas essayer d entretenir lui même le scanner ou le laser N...

Page 15: ...by the party responsible for compliance could void the user s authority to operate the equipment Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters 9 8 feet when fully extended Les instructions ci dessous s appliquent aux cables de scanner dépassant 3 métres 9 8 pieds de long en extension maximale Folgendes trifft zu wenn das Scannerkabel länger a...

Page 16: ... cause radio interference in which case the user may be required to take adequate measures Funkstöreigenschaften nach EN55022 1998 Warnung Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen In diesem Fall kann vom Betreiber verlangt werden angemessene Massnahmen durchzuführen Standard Europeo Attenzione Questo e un prodotto di classe A Se usato i...

Page 17: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation ...

Page 18: ...rty patent listed above except for an implied license only for the normal intended use of the specific equipment circuits and devices represented by or contained in the products that are physically transferred to the user and only to the extent of those license rights and subject to any conditions covenants and restrictions therein Other worldwide patents pending All features can be enabled or dis...

Page 19: ... Disable CR Suffix Enable LF Suffix The scanner transmits a line feed after each barcode Disable when Keyboard wedge defaults are loaded Disable LF Suffix Enable Tab Suffix The scanner will transmit a TAB ASCII 09H after the each barcode Enter Exit Configuration Mode Recall Defaults 3 9 9 9 9 9 8 3 8 4 6 6 0 0 3 116613 3 1 1 6 6 1 3 3 1 1 6 6 0 3 3 116603 3 116612 3 1 1 6 6 1 2 3 116602 3 1 1 6 6 ...

Page 20: ...byte for Configuration require that the scanner be in configuration mode The Enter Exit Configuration Mode bar code must be scanned before starting the configuration cycle Example User configurable Minimum Characters can then be saved in to the scanner by scanning the appropriate code byte character barcodes To Program Minimum Symbol Length to one 1 Enter Exit Configuration Mode 3 beeps 2 Configur...

Page 21: ...21 3 2 Code Byte 2 3 3 Code Byte 3 3 4 Code Byte 4 3 5 Code Byte 5 3 6 Code Byte 6 3 7 Code Byte 7 3 8 Code Byte 8 3 9 Code Byte 9 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 ...

Page 22: ...on 3 118703 Interfaces Enable USB Interface Enable USB Serial Emulation Mode Enable RS232 Interface Load Keyboard Wedge Defaults Enable Keyboard Wedge Emulation Country scan code Table Select USA Keyboard 3 416260 3 1 1 8 7 1 3 3 1 1 8 7 0 3 3 4 1 5 5 1 1 4 3 3 1 6 4 7 0 3 4 1 5 5 5 4 3 9 9 9 9 9 4 3 5 1 5 5 1 4 3 3 4 1 6 2 6 0 ...

Page 23: ...Italy Keyboard 3 416240 German Keyboard 3 416230 France Keyboard 3 416220 UK Keyboard 3 416210 Belgium Keyboard 3 416200 Japan Keyboard 3 4162100 3 4 1 6 2 5 0 3 4 1 6 2 4 0 3 4 1 6 2 3 0 3 4 1 6 2 2 0 3 4 1 6 2 1 0 3 4 1 6 2 0 0 3 4 1 6 2 1 0 0 3 4 1 6 2 8 0 ...

Page 24: ...Voyager 3 216205 PS 2 Keyboard Includes IBM PC and compatible model 30 70 8556 3 216225 Enable Terminal Keyboard Emulation 3 216235 For any further configuration can download the Metro select configuration guide from the below link http www honeywellaidc com Site aspx ap en product_ center product_support category 5 product 296 3 4 1 6 2 7 0 3 4 1 6 2 9 0 3 2 1 6 2 1 5 3 2 1 6 2 0 5 3 2 1 6 2 2 5 ...

Reviews: