36-KI-16-29
Page 2 of 3
Availability
MGG17D
TABLE I (Continued)
Selection
D - Electrodes
SUS316L
_ _ _ _ _ _ L _ _ _ _ _
*
Hastelloy C
(with Teflon PFA only)
_ _ _ _ _ _ C _ _ _ _ _
c
Titanium
_ _ _ _ _ _ K _ _ _ _ _
Zirconium
(with Teflon PFA only)
_ _ _ _ _ _ H _ _ _ _ _
c
Tantalum
(with Teflon PFA only)
_ _ _ _ _ _ T _ _ _ _ _
c
Tungsten Carbide
(only for size 10mm and above)
_ _ _ _ _ _ W _ _ _ _ _
e
Platinum-Iridium
(with Teflon PFA only)
_ _ _ _ _ _ P _ _ _ _ _
c
Alloy 20
(with Teflon PFA only)
_ _ _ _ _ _ A _ _ _ _ _
c
Hastelloy B
(with Teflon PFA only)
_ _ _ _ _ _ B _ _ _ _ _
c
SUS304
(with Teflon PFA only)
_ _ _ _ _ _ E _ _ _ _ _
c
Monel
(with Teflon PFA only)
_ _ _ _ _ _ M _ _ _ _ _
c
Nickel
(with Teflon PFA only)
_ _ _ _ _ _ N _ _ _ _ _
f
SUS316L Protruded Tip
(with Teflon PFA 15-200mm only)
_ _ _ _ _ _ 1 _ _ _ _ _
f
SUS316L for Alumina with Flat Tip
(with Teflon PFA 15-200mm only)
_ _ _ _ _ _ 2 _ _ _ _ _
f
SUS316L for Alumina with Pointed Tip
(with Teflon PFA 15-200mm only)
_ _ _ _ _ _ 3 _ _ _ _ _
f
E - Grounding Rings
SUS316
_ _ _ _ _ _ _ S _ _ _ _
*
SS Top Hat Style (Upstream Only)
_ _ _ _ _ _ _ G _ _ _ _
c
Hastelloy C
(with Teflon PFA only)
_ _ _ _ _ _ _ C _ _ _ _
c
Titanium
_ _ _ _ _ _ _ K _ _ _ _
Zirconium
(with Teflon PFA only)
_ _ _ _ _ _ _ H _ _ _ _
c
Tantalum
(with Teflon PFA only)
_ _ _ _ _ _ _ T _ _ _ _
c
Platinum
(with Teflon PFA only)
_ _ _ _ _ _ _ P _ _ _ _
c
Alloy 20
(with Teflon PFA only)
_ _ _ _ _ _ _ A _ _ _ _
c
Hastelloy B
(with Teflon PFA only)
_ _ _ _ _ _ _ B _ _ _ _
c
SUS304
(with Teflon PFA only)
_ _ _ _ _ _ _ E _ _ _ _
c
SUS316L
(with Teflon PFA only)
_ _ _ _ _ _ _ L _ _ _ _
c
Nickel
(with Teflon PFA only)
_ _ _ _ _ _ _ N _ _ _ _
c
F - Wiring Connection
1/2" NPT Internal Thread without Watertight Gland
_ _ _ _ _ _ _ _ 5 _ _ _
*
G - Face to Face Dimension
Standard
_ _ _ _ _ _ _ _ _ A _ _
*
Competitive
(Refer to Table 103 and Consult Factory)
_ _ _ _ _ _ _ _ _ 9 _ _
H - Installation/Wiring Direction - Remote Only
Upstream Side (horizontal/vertical piping mounting)
_ _ _ _ _ _ _ _ _ _ A _
*
Downstream Side (horizontal/vertical piping mounting)
_ _ _ _ _ _ _ _ _ _ B _
Horizontal Piping Mounting/Left Side Viewed from Upstream
_ _ _ _ _ _ _ _ _ _ C _
Horizontal Piping Mounting/Right Side Viewed from Upstream
_ _ _ _ _ _ _ _ _ _ D _
I - Calibration
Standard Calibration - 2 Point (0, 100%) w/ Master Converter
_ _ _ _ _ _ _ _ _ _ _ R
*
3 Point (0, 50, 100%) with Master Converter
_ _ _ _ _ _ _ _ _ _ _ P
5 Point (0, 25, 50, 75, 100%) with Master Converter
_ _ _ _ _ _ _ _ _ _ _ Q
2 Point (0, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ J
3 Point (0, 50, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ A
5 Point (0, 25, 50, 75, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ E