background image

4

ENGLISH

IMPORTANT SAFETY INSTRUCTIONS

1. As the power voltage should remain as steady as possible (between 212V and
264V) without big fluctuations, use correct power supply according to the existing
data on the rating label. 

2. Never insert an object or finger through the air discharge grid of the indoor and
outdoor unit. This may cause bodily injury and damage the unit. Furthermore do not
put any objects on the indoor and outdoor unit. Keep the air conditioner free from
any obstructions. Make sure that the air intake vent and air outlet vent are open
before starting to use the air conditioner. Do not allow objects to get into the air
intake vent or air outlet vent. Do not cover up the air conditioner. This can lead to
overheating, fire or electric shock.

3. After pressing a key the unit will start operation with a delay of 3-4 minutes to
avoid damage to the compressor.

4. Only connect the air conditioner to an earthed single-phase power socket with the
current as stated on the rating label. Before connecting the air conditioner to a
power socket, make sure that the socket is provided with an earth connection in
compliance with local codes. Switch the air conditioner off and disconnect the
power plug from the power socket when the air conditioner is not in use and before
cleaning. Do not tug at the power cord to disconnect the plug. Unwind the power
cord completely. An incompletely unwound power cord can lead to overheating and
cause a fire. Do not touch the power cord with wet hands. Make sure that there are
no objects resting on the power cord or that it could come into contact with hot
parts. Positions where the power socket is easily accessible. Do not use an
extension cord, a multiway connector or an infinitely variable speed controller.
These can lead to overheating, fire or electric shock.

5. The connection of the quick connection must be done according to this
instruction to prevent system leakage and damaging compressor.

6. Doors or windows can be open slightly for ventilation if the indoor air is too
turbid; when the unit is running, draw curtain or cover window to prevent leakage of
cool air or heat that may impact the air conditioning effect. While using the Cooling,
Heating or Drying mode make sure that all windows are closed.

7. If the power cord of the air conditioner is damaged, it must be replaced by the
manufacturer, at a manufacturer-approved repair shop or by similarly qualified per-
sons, so as to avoid damage. Do not attempt to open or repair the unit by yourself,
as this could cause damage to persons and property. Do not operate the air
conditioner if it is damaged or might be defective, or if it is not working properly.
Remove the power plug from the socket.

8. Close supervision is necessary when this air conditioner is used by or near chil-
dren or infirm persons.

9. Do not use the air conditioner in any kind of vehicle (e.g. portcabin, platform
truck, lift, motor vehicle, cubicle) or similar enclosed space.

10. Do not use the air conditioner anywhere near flammable gases or substances
such as solvents, lacquers, glues etc.

11. Do not immerse the air conditioner in water or any other liquids and do not pour
water or any other liquids over the appliance or into the air intake vent or air outlet
vent. Clean the air conditioner regularly by following the cleaning instructions.

12. The air conditioner must only be used according to the instructions in this
instruction manual. Non-observance of these instructions can result in injuries, fire,
electric shock or defects in the appliance.

13. The air conditioner must not be located behind curtains or other objects and
obstacles which could interrupt the air circulation. Make sure that no objects can get
into the air intake vent or discharge vent. Never put objects on the top of the unit.

14. Do not unplug the air conditioner while it is operating. First switch it OFF with
the power key.

15. Before starting to operate this air conditioner, make sure it is fully mounted and
assembled according to these instructions.

16. Do not expose persons, pet or houseplants to direct airflow. This could damage
health, the pet or plant.

HW-QUICK12E_GB_OM.qxd  4/2/07  12:04 PM  Page 4

Summary of Contents for HW-QUICK12E

Page 1: ...ase of low temperatures Sleep mode Suitable for rooms up to approx 125 m 1 Optimal air circulation due to an adjustable air outflow grid Infrared remote control for easy handling Timer function Pilot light Environmentally friendly refrigerant R410a CFC free 1 To calculate the optimal cooling capacity the following rule can be taken as basis Usually the air conditioning of 1 m requires 60 to 100 Wa...

Page 2: ...ruksanvisning KLIMAAPPARAT TIL SELVMONTAGE Betjeningsvejledning ITSEASENNETTAVA ILMASTOINTILAITE Käyttöohje KEND KEND N ZE MONTE EDEB LECE N Z KL MA C HAZI Kullan m Talimatlar KLIMATIZAČNÍ PŘÍSTROJ PRO VLASTNÍ MONTÁŽ Návod k použití KLIMATIZACIJSKI URE AJ ZA SAMOMONTAŽU Upute za uporabu KLIMATSKA NAPRAVA ZA SAMOSTOJNO MONTAŽO Navodilo za uporabo SI HR CZ TR FI DK SE ES FR DE GB HW QUICK12E HW QUIC...

Page 3: ... and no responsibility is accepted by the manufacturer for damages or injury s caused by this air conditioner as a result of incorrect usage or installation CONTENT Construction and Usage Installation Maintenance Construction of the wall mounted split air conditioner 3 Precautionary and safety measures 4 Specification model and technical parameter 5 Remote control function keys 6 Operation guide 9...

Page 4: ...re may vary from original product Air Inflow 1 Front Panel 2 Air Filter 3 Emergency Operation switch 4 Display 5 Oscillating Louvers 6 Power Plug 7 Drainage Hose 8 Air Discharge Grid 9 Remote Control 10 Cover of Quick Connector 11 Active Carbon Filter 9 11 8 10 Operating Indicator Set Temperature Standby light glows green DeHumidifing Air Inflow INDOOR UNIT Air Discharge OUTDOOR UNIT D C B A A B C...

Page 5: ...en slightly for ventilation if the indoor air is too turbid when the unit is running draw curtain or cover window to prevent leakage of cool air or heat that may impact the air conditioning effect While using the Cooling Heating or Drying mode make sure that all windows are closed 7 If the power cord of the air conditioner is damaged it must be replaced by the manufacturer at a manufacturer approv...

Page 6: ...anteed operating range HWQUICK12E SPECIFICATIONS AND TECHNICAL PARAMETERS Model Function Cooling capacity W Heating capacity W Voltage frequency V Hz Rated current of cooling heating A Max input current A Rated power of cooling heating W Air flow m3 h Refrigerant type and standard charge volume kg Water proof level Noise indoor outdoor dB A Climate type Anti electric shock protect type Weight indo...

Page 7: ...al display It shows all selected functions B 2 SLEEP key Press this key to select SLEEP Mode C 3 TIMER OFF key During operation press this key to select OFF TIME between 0 and 24 hours to stop the unit automatically after selected delay D 4 TIMER ON key During no operation press this key to select ON TIME between 0 and 24 hours to start the unit automatically after selected delay E 5 ON OFF key Pr...

Page 8: ...range of 16 C to 30 C DRY Mode If the room temperature is within 2 C of the set temperature on the remote con trol the air conditioner operates in DRY Mode only If the room temperature rises outside of this range the unit will change to the COOL Mode until the room tem perature is within the range of 2 C again The room temperature can be set between the range of 16 C to 30 C AUTO Mode In AUTO Mode...

Page 9: ...n at low speed When the unit is off press TIMER ON key and set ON TIME in a range of 0 to 24 hours to start the unit automatically When the unit is operating press TIMER OFF key and set OFF TIME in range of 0 to 24 hours to stop the unit auto matically 2 Press MODE key to set and mode to ensure comfortable effect 6 Press SLEEP key to set SLEEP Mode 1 Plug in press ON OFF key then the air condition...

Page 10: ...tems such as curtain or clothes Install the unit horizontally Make sure the air outlet vents are not blocked Do not install the outdoor unit in a closed room it is to be installed in a place with good ventilation Ensure that the installation of the outdoor and indoor unit meets the requirements of following installing dimensions CAUTION Avoid the following places for installation where air conditi...

Page 11: ...alling dimensions leaving enough space for maintenance It should be positioned so that the air can circulate freely 2 Place the unit where air filters and active carbon filters can be taken out easily Above 15 cm Above 300 cm Wall pipe Abo ve 200 cm Above 15 cm Above 15 cm Distance between unit and wall Distance between unit and ceiling Distance between unit and floor Air discharge Distance betwee...

Page 12: ...routed both Methods 1 2 3 and 4 are recommended NOTE In order not to damage the piping we recommend to only bend them once very gently Furthermore it is essential when you extend the pipes liquid and gas pipe that you fill in additional coolant into the system in order to achieve an effective and correct functioning of the air conditioner 150g 2m 2 Hang the suspension slot positioned on the rear s...

Page 13: ...or unit After disassembling the cover of the quick connector of the outdoor unit you are able to see the female part of the quick connector The male part of the quick connector is at the end of the pipes that are assembled at the indoor unit The pipes are pre filled with refrigerant gas Follow the instructions to connect the quick connector In order to minimise the potential for fluid losses alway...

Page 14: ...e male part of the quick connector to install the quick connector correctly Orientating Pin Tightening lever 5 Pull the tightening sleeve on at the female part of the quick connector back and hold it back Tightening sleeve 3 Remove the metal protection cap off the quick connector end of the outdoor unit by pulling back the tightening sleeve of that quick connector end and by pulling out the metal ...

Page 15: ... the female part of the power clamp on the Terminal Board Connect these two parts by sliding the male part of the power clamp into the female part of the power clamp After you checked that the two parts of the power clamp are firmly fixed and connected fix the power cord of the female part by assembling the fixation clamp at the outdoor unit Ensure that the black insulated power cord part has been...

Page 16: ...ck if there is an abnormal noise vibration or water leakage at the indoor unit and outdoor unit as well as at the quick connector If everything is ok with the complete unit and you do not have to disassemble the unit to correct mistakes produced during installation use the delivered gum type sealer to close vents around the connection piping and wiring within the hole of the wall Bottom of Outdoor...

Page 17: ...stic anti dust air filters and active carbon filters Clean the plastic anti dust air filters and active carbon filters by shaking or vacuu ming them Use lukewarm water to wash the filters Do not use water with more than 45 C for cleaning to avoid fading or deformation of the filters Do not use the dishwasher to clean the filters Afterwards dry the filters thoroughly Do not expose them to direct su...

Page 18: ...ing or heating effect Is the temperature set correctly on the remote control Are the inlet or outlet vents of outdoor unit blocked Is there too much dust on the air filters Are windows and doors closed Is the airflow set too low Is there any heat source in the room Remote control does not control If batteries of the remote control are changed it is necessary to press key ACL after removing the cov...

Page 19: ...collection service or in the store at which you bought the product This regulation is valid only in EU member states CONDITION OF PURCHASE As condition of sale the purchaser assumes responsibility for the correct use and care of this KAZ product according to these user instructions The purchaser or user must himself or herself decide when and for how long this KAZ product is in use ATTENTION IF PR...

Page 20: ...tdoor unit l x w x h Dimensions single box approx cm 98 x 37 x 36 5 Indoor unit l x w x h Weight of single box indoor unit approx kg 20 Weight of single box outdoor unit approx kg 34 1 To calculate the optimal cooling capacity the following rule can be taken as basis Usually the air conditioning of 1 m requires 60 to 100 Watt Slants of a roof large glass window surfaces humidity and additional fac...