![Honeywell HRO-50 Product Installation & Operation Manual Download Page 10](http://html.mh-extra.com/html/honeywell/hro-50/hro-50_product-installation-and-operation-manual_155091010.webp)
Flush and Start Water Purifier
The
water purifier must be
flushed
manually and automatically at
the
first installation and
replacement.
1) Manual flush:
Pull out
the
th
readed flow-limiting plug in
the
wastewater outlet (clean
the
groove if it is
dirty). Plug in
the
power, turn on
the
water inlet valve and small ball valve, and
flush
for
about 2-5 minutes. Turn of
f the small ball valve.
2) Automatic flush:
Check whether all the water pipes a
re installed correctly and completely.
4) Confirm
that
the
flushing
is complete, turn off
the
water faucet and complete
the
commissioning.
Installation Instructions
9
Install the threaded flow-limiting plug into the wastewater pipe. Open the small ball valve
to produce water. Meanwhile, open the water faucet to exhaust the air. Wait until the
water faucet is exhausted completely, and close the faucet after the water flow is steady.
After the storage tank is full in about 45~60 minutes, open the water faucet to discharge
all the water in the storage tank.
3) Check the tightness at various each part of the product carefully when flushing. Wipe
all the connections with tissue paper to see whether it is wet.