8 Accumulating Trend Analysis Over a Period of Years

Trending of periodic Mhos measurements can yield valuable insights for estimating the remaining life of the battery.  
Suppose that a 4.0 Ah battery has been in service for three years and that the LifeTester measurements after the first year 
was 90 Mhos, 85 Mhos after the second year, and 80 Mhos after the third.  Since the battery is still at 80 Mhos and is 
dropping an average of 5 Mhos per year, it is likely that this battery will not need replacing before the end of the fourth 
year.  On the other hand, suppose that the readings were 90 Mhos after the first year, 82 Mhos after the second year, and 
70 Mhos after the third, the rate of decay increasing each year.  This indicates that although the battery is still serviceable, 
it is degrading more and more rapidly.  It is unlikely that this battery will be serviceable for another year.  Under these 
circumstances, either the battery should be replaced early or the service interval should be shortened to catch this battery 
before a system failure.

9 Using Mhos to Estimate Battery Life

For standby batteries, peak capacity is normally reached after about three months on a float charging system.  For cyclic 
use batteries, full capacity may not be reached until after ten to thirty cycles.  If a new battery has been in storage for an 
extended period, say over six months without being charges, plate oxidation from self-discharge will occur, causing a 
decrease in the Mhos reading.  Plate oxidation also occurs in standby batteries during a power failure, particularly if a 
battery remains in a highly discharged state for an extended period of time.  Plate oxidation is unhealthy and can destroy a 
battery’s capacity.  Once a battery is weakened by plate oxidation, it is difficult to recover full capacity without special 
charging or conditioning methods.  In some cases a battery will recover and pass a test after being recharged.  However, a 
second test should be performed a few days later to accurately assess the overall life of the battery.  The average life cycle 
of a sealed lead-acid battery in standby use on a float charge is three to five years.  A battery with a Mhos reading of less 
that 70% of its original capacity is no longer considered serviceable and should be replaced.

Continued on next page...

Summary of Contents for HPBLT

Page 1: ...4 W x 3 H x 1 15 D w o carrying case 4 Installation Instructions 1 Disconnect the battery from its equipment 2 Connect the BLACK test clip to the Negative battery terminal and the RED to the Positive terminal For accurate readings the test clips must be tightly clipped directly to the battery posts not to the battery bolts Err or a blank screen indicates that battery voltage is too low for testing...

Page 2: ...e current the battery can deliver Therefore a new 7 amp hour battery will have a higher Mhos value than a new 4 amp hour battery of similar construction 6 Temperature Effects on a Battery Generally speaking temperatures below 72 F tend to slow down a battery s internal activity causing a significant decrease in the Mhos conductivity reading as the temperature falls Cool temperatures not below free...

Page 3: ...y before a system failure 9 Using Mhos to Estimate Battery Life For standby batteries peak capacity is normally reached after about three months on a float charging system For cyclic use batteries full capacity may not be reached until after ten to thirty cycles If a new battery has been in storage for an extended period say over six months without being charges plate oxidation from self discharge...

Page 4: ... 134 152 153 171 172 0 125 126 143 144 161 152 8 0 0 157 158 179 180 202 203 0 144 145 165 166 185 186 0 136 137 156 157 175 176 0 128 129 147 148 165 166 10 0 0 185 186 211 212 238 239 0 170 171 194 195 218 219 0 160 161 183 184 206 207 0 151 152 173 174 195 196 12 0 0 192 193 219 220 241 248 0 176 177 201 202 227 228 0 166 167 190 191 214 215 0 157 158 179 180 202 203 17 0 0 265 266 303 304 341 ...

Reviews: