2. General 

The HERMetic OXY is designed for sampling inert gas in closed tanks before crude oil washing. It 
consists of a rubber sampling hose with an on-line valve at the upper end, an open hose end for 
connecting to a portable gas analyzer (not supplied with the OXY), a weight at the lower end and 
an adapter with a hose adjusting nut. 
 
It is made for connecting to the HERMetic valves. When the OXY is connected to the valve, the 
operation is carried out with negligible escape of gas to the atmosphere. 

 
 
 
 
 

3. Recommendation for safe use 

 

This Operation and Service Manual is a guide in order to help the user to operate the instrument 
safely and correctly. 
 
Nevertheless the maker disclaims all responsibility and liability for damage resulting from the use 
of the equipment regardless of the cause of the damage. 

 

The I.M.O. requirements on Tanker Safety and Pollution Prevention, 1978 - resolution A.446 (XI) - 
§ 6.6 states: 
 

“Before each tank is crude oil washed, the oxygen level shall be determined at a point 1 
meter from the deck and at the middle region of the ullage space and neither of these 
determinations shall exceed 8 per cent by volume.” 

 
This product and his use is / may be related to international, national, local or company regulations 
or standards. It is the customer / user responsibility to ensure that the way to use the device 
complies with such applicable regulations or standards. 
 
This device is a portable product. It must not be permanently installed on the tank and must be 
disconnected after use and stored in a safe and dry area. 

 

Summary of Contents for HERMetic OXY

Page 1: ...and Service Manual for HERMetic OXY all versions Note before using the instrument please read this book This document is subject to changes without notice Check updates on www tanksystem com or contact us at tanksystem honeywell com ...

Page 2: ...ION FOR SAFE USE 3 4 GENERAL INFORMATION 4 4 1 DISCLAIMER 4 4 2 SHIPMENT NOTE 4 4 3 INITIAL INSPECTION 4 4 4 DOCUMENTATION DISCREPANCIES 4 4 5 WARRANTY 4 4 6 SPARE PARTS 5 4 7 SERVICE AND REPAIR 5 5 WORLDWIDE SERVICE STATIONS NETWORK 7 5 OPERATION 9 6 MAINTENANCE 9 6 1 CARE 9 7 DRAWINGS 10 ...

Page 3: ...rtheless the maker disclaims all responsibility and liability for damage resulting from the use of the equipment regardless of the cause of the damage The I M O requirements on Tanker Safety and Pollution Prevention 1978 resolution A 446 XI 6 6 states Before each tank is crude oil washed the oxygen level shall be determined at a point 1 meter from the deck and at the middle region of the ullage sp...

Page 4: ...dy any defect resulting from faulty design materials or workmanship The Vendor s obligation is limited to the repair or replacement of such defective parts by his own plant or one of his authorized service stations The Purchaser shall bear the cost and risk of transportation of defective parts and repaired parts supplied in replacement of such defective parts This warranty does not apply to those ...

Page 5: ...n ordering spares identify the spare part by TS number and description Refer to section Drawings Some spares might be repairable in this case send part to any authorized service center or to the factory In case of urgency replacement units can be available while stocks last 4 7 Service and Repair The customer should take care of the freight and customs clearance charges If units are sent on freigh...

Page 6: ...ce Request Customer s address Telephone Telex Fax Type of unit or part Short description of defective unit or part Do you want a quotation before repair is started yes no Repaired unit has to be returned to the following address ...

Page 7: ... P C 201315 Tel 86 21 68183183 Fax 86 21 68183115 huahaish huahaiee com GREECE SPANMARIN 86 Filonos Street GR 185 36 PIRAEUS Tel 30 210 4294498 Fax 30 210 4294495 spanmarin ath forthnet gr JAPAN DAIWA HANBAI CORPORATION LTD 2 10 31 Mitejima Nishiyodogawa ku OSAKA 555 0012 Tel 81 6 64714701 Fax 81 6 64729008 daiwa471 silver ocn ne jp KOREA World Ocean CO LTD Rm1001 Hae deok Bldg 1212 11 Choryang do...

Page 8: ...746263 Fax 34 94 4745868 eni tecnica eni es SWEDEN INSTRUMENTKONTROLL Lars Petersson AB Varholmsgatan 1 414 74 GÖTEBORG Tel 46 31 240510 Tel 46 31 240525 Fax 46 31 243710 Info instrumentkontroll se TURKEY YEDI DENIZ Setustu Izzetpasa Yok 1 TR 34427 Kabatas ISTANBUL Tel 90 212 251 64 10 3 lines Fax 90 212 251 05 75 servicestation yedideniz net UNITED ARAB EMIRATES MARITRONICS TRADING L L C P O Box ...

Page 9: ... OXY at the free end of the ose 7 Open the on line valve 8 Follow the operation instructions of the monitoring equipment manufacturer 9 When the oxygen content is determined close the on line valve slacken the adjusting nut and pull out the hose 10 Take care not to damage the hose when through edge of hatch cover 11 When the weight is stored in the OXY tube close the HERMetic Compact Deck valve an...

Page 10: ... Drawings ND TS DESCRIPTION 30276 10070 OXY 15m Tanol hose St St 1 30408 10011 OXY 15m Tanol hose 1 30409 10012 OXY 30m Tanol hose 1 30413 10009 OXY without hose 30414 10071 OXY 30m Tanol hose St St 1 41039 22564 Adaptor 1 2 ...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Reviews: