Honeywell HEAT PUMP THERMOSTAT T8411R Manual Download Page 4

T8411R ELECTRONIC HEAT PUMP THERMOSTAT

68-0185—2

4

Fig. 3. Mounting wallplate to wall.

Wiring

IMPORTANT

Use 18-gauge thermostat cable for proper wiring.

All wiring must comply with local electrical codes and 

ordinances. 

CAUTION

Damage to Heating/Cooling System Possible.

Be careful when handling wires during 
installation.

Disconnect power at furnace or main breaker/fuse box.

The shape of the terminals permits insertion of straight or 

wraparound wiring connections; either method is acceptable. 

See Fig. 4.

Fig. 4. Wiring connections.

NOTE: Restrict all wiring to the shaded area between the 

terminals. See Fig. 5.

Refer to Fig. 6 for typical wiring hookup. A letter code is 

located near each terminal for identification.

1.

Loosen the terminal screws on the wallplate and con-

nect the system wires. See Fig. 4.

2.

Securely tighten each terminal screw.

3.

Push the excess wire back into the hole.

4.

Plug the hole with nonflammable insulation to prevent 
drafts from affecting the thermostat.

Mounting Thermostat to Wallplate

1.

Engage the tabs at the top of the thermostat and wall-

plate.

2.

Swing down the thermostat and press the lower edge of 

the thermostat onto the wallplate to latch. See Fig. 7.

Fig. 5. Restrict wiring to shaded area.

M12202A

WALL

WALL  
ANCHORS (2)

WALLPLATE

WHEN USING WALL ANCHORS, DRILL 3/16 INCH 
HOLES FOR DRYWALL, 7/32 INCH HOLES FOR
PLASTER OR WOOD.

MOUNTING 
SCREWS (2)

1

1

TERMINAL 
SCREW

M11334A

G

C

R

Y

W1

L

W2

E

B

O

FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM)

FOR WRAPAROUND
STRIP 7/16 IN. (11 MM)

1

NOT ALL MODELS HAVE BOTH O AND B TERMINALS.

1

KEEP WIRING IN
SHADED AREA

MOUNTING 
SCREW HOLE

MOUNTING 
SCREW HOLE

WIRING ENTRANCE
HOLE

M11331A

G

C

R

Y

W1

L

W2

E

B

O

1

NOT ALL MODELS HAVE BOTH O AND B TERMINALS.

1

Summary of Contents for HEAT PUMP THERMOSTAT T8411R

Page 1: ...in a variety of locations Keys are located by the display for easy access Fan and system switches are located on the lower edge to eliminate accidental setting changes Easy installation setup and self test saves installer time and increases their productivity Manual changeover from heat to cool eliminates unexpected system operation F or C temperature display for added model flexibility Selectable...

Page 2: ...1R TRADELINE model includes a thermostat wallplate for wiring and mounting thermostat and owner s guide Power T8411R 24 Vac nominal 18 to 30 Vac 50 60 Hz Electrical Ratings First Stage Heating 0 02 to 1 5A run 7 5A inrush Second Stage Heating 0 02 to 1 5A run 3 5A inrush Cooling 0 02 to 1 5A run 7 5A inrush Fan 0 02 to 0 5A run 2 5A inrush Emergency Heat Output E 0 02 to 1 5A run 3 5A inrush Heati...

Page 3: ...on Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average room temperature See Fig 2 Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in corners hot or cold air from ducts radiant heat from the sun or appliances concealed pipes and chimneys unheated uncooled areas such as an outside wall behind the therm...

Page 4: ...ate and con nect the system wires See Fig 4 2 Securely tighten each terminal screw 3 Push the excess wire back into the hole 4 Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat Mounting Thermostat to Wallplate 1 Engage the tabs at the top of the thermostat and wall plate 2 Swing down the thermostat and press the lower edge of the thermostat onto the wallpla...

Page 5: ... TERMINALS SYSTEM SWITCH HEAT OFF COOL R W2 L B O Y EM HT W1 E AUXILARY HEAT RELAY CHANGEOVER VALVE HEAT CHANGEOVER VALVE COOL COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR HEAT FAN RELAY RELAY EMERGENCY HEAT RELAY G C THERMOSTAT LOGIC THERMISTOR SENSOR POWER SUPPLY ON AUTO STAGE 2 RELAY STAGE 1 RELAY FAN SWITCH M11333A 3 3 M18577 SYSTEM Cool Off Heat Em Ht Auto On FAN DASHED LINES INDICATE TABS ON BA...

Page 6: ...heating load Set Temperature Setpoint NOTE Temperature setpoint range is 40 to 99 F 4 to 39 C The temperature setpoint and the room temperature are shown separately on the display The indicator points to Set when the temperature setpoint is displayed and to Room when the room temperature is displayed To set temperature setpoint 1 Select Heat or Cool by sliding the SYSTEM switch in the lower right ...

Page 7: ... displayed A typical example is shown but CC varies by model This informa tion is for factory use only 10 Press to save all changes exit installer setup mode and return to normal operation NOTE After exiting installer setup mode change the set point to the desired room temperature OPERATION The T8411R Thermostat provides two stage heat and one stage cool temperature control with proportional plus ...

Page 8: ...ting and cooling Table 1 Sequence of Operations a The O terminal is powered continuously in cooling the B terminal is powered continuously in heating and the L terminal is powered continuously in emergency heat as a function of the system switch position even without a call for heat or cool CHECKOUT Heating 1 Slide the SYSTEM switch to Heat and the FAN switch to Auto 2 Press and hold the s key to ...

Page 9: ... THERMOSTAT PARTIAL DISPLAY INOPERATIVE THERMOSTAT SEE THE SETTINGS AND ADJUSTMENTS SECTION FOR INSTRUCTIONS ON INSTALLER SETUP MODE STILL IN INSTALLER SETUP MODE RECONFIGURE THE DISPLAY SEE SETTINGS AND ADJUSTMENTS SECTION TEMPERATURE DISPLAY IS INCORRECT THERMOSTAT IS CONFIGURED FOR F OR C DISPLAY CHECK THAT C TERMINAL IS CONNECTED TO THE SYSTEM TRANSFORMER CHECK POWER TO HEATING AND COOLING EQU...

Page 10: ...68 0185 2 10 ...

Page 11: ...11 68 0185 2 ...

Page 12: ...ilding Control Home and Building Control Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...

Reviews: