Setting the Baud Rate and Video Format 

The baud rate and video format are set using the 4-position DIP switch. 
Use the following tables as a reference: 

Baud Rate 

9600 bps 

OFF 

OFF 

4800 bps 

ON 

OFF 

2400 bps 

OFF 

ON 

1200 bps 

ON 

ON 

Video Format 

CVI 

OFF 

OFF 

TVI 

OFF 

ON 

AHD 

ON 

OFF 

SD 

ON 

ON 

Connecting the Cables 

Power 

Red 

24 V AC 

Black 

24 V AC 

Yellow & Green 

Earth 

RS485 

Yellow 

A+ 

Orange 

B- 

Video Out 

BNC 

Audio 

White 

Audio IN 

Black 

Audio GND 

Alarm 

Blue 

Alarm OUT 1 

Green 

Alarm COM1 

Red 

Alarm IN1 

Brown 

Alarm IN2 

Yellow & Green 

Alarm GND 

Recommended Cables and Maximum Distances 

Type 

Recommended Cable 

Maximum Distance 

Power 

18 AWG 2-conductor 

153 ft (46.5 m) 

Data 

Cat5 24 AWG twisted pair  (use 

shielding in high electrical 

interference locations) 

5905 ft (1800 m) @ 2400 bps 

3937 ft (1200 m) @ 4800 bps 

2625 ft (800 m) @ 9600 bps 

Video 

RG-59/U coaxial cable with BNC 

crimp, 75 ohm, copper conductor 

750 ft (229 m) 

Alarm 

Belden 8205 

10,000 ft (3048 m) 

RS-485 Connection Guidelines 

Data termination (120 ohm) is set at the rear of the camera, next to
the DIP switches. It is open by default, with the jumper over pins 2 and 
3. To terminate the camera, place the jumper over pins 1 and 2 (see 
figure at right).

In an RS485 bus, terminate the two endpoints to prevent signal reflection. If a
star topology is used, terminate all connected PTZ cameras and use an RS485
data distributor (such as HDCD8TP).

Note

: For more information, please refer to the HDZP30XD4 user guide (800-23522). The 

guide is available for download from www.honeywellvideo.com.  

Mounting the Camera 

The wall mount weighs 1.08 lb (0.49 kg) and can be installed directly to a load-bearing 
wall, or to a corner or pole using an appropriate adapter.  

Important!   

Ensure that the mounting surface can support at least three times the 

combined weight of the camera and mount (at least 27.72 lb/12.57 kg).

 

Configuring the OSD Menu Settings 

When the camera is connected to a Honeywell Performance Series DVR (HRHQXXXX/ 
HRHTXXXX), you can access and configure the camera’s on-screen display (OSD) menu 
using either the HQA or RS485 control modes. 

OSD Configuration:  Up-the-Coax 

Note:

 The DVR’s PTZ control mode and protocol must be set to 

HQA

 (in 

Main Menu > 

Setting > System > PTZ

) for up-the-coax control of the OSD menu. 

1.

 

Verify that the camera is connected to a Honeywell Performance Series DVR. 

2.

Turn on the DVR, right-click to display the shortcut
menu, then click 

Camera Menu

.

3.

Log on to the DVR as the admin user. The 

Menu

Operation

 window opens.

4.

Click 

Enter

 to display the camera’s OSD menu.

5.

To configure OSD settings, in the 

Menu Operation

window, click the up or down arrows to move through

the menu list, click the left or right arrows to change
a setting, or click 

Enter

 to enter a submenu (

) or execute a command.

6.

After you have finished configuring the camera, scroll down to 

Exit

, and then click

Enter

 to exit the OSD menu. Right-click to close the 

Menu Operation

 window. 

OSD Configuration:  RS485 

Note:

 The DVR’s PTZ control mode must be set to 

Serial

 (in 

Main Menu > Setting > 

System > PTZ

) for RS485 control of the OSD menu. 

Task 

Action 

To display the OSD menu 

Call 

Preset 95

To scroll through the OSD menu 

Move the joystick up or down. 

To change a setting 

Move the joystick left or right. 

To open a submenu (

) or  

execute a command 

Press 

Iris +

 (Iris Open). 

To exit the OSD menu 

Press 

Iris –

 (Iris Close). 

Power

Audio

Alarm

RS485

Video

Out

1.

Loosen the mount locking
screw.

2.

Screw the adapter to the
mount. 

3.

Tighten the mount locking
screw.

4.

Loosen the three locking
screws on the adapter.

5.

Feed the camera cables
through the mount. 

6.

Attach the camera body to the

adapter and tighten the three
locking screws to secure the
camera body to the mount. 

7.

Make connections of the
camera cables with the cables
fed through the wall.

8.

Attach the mount to the wall
using appropriate hardware.

4

6

1/3

5
2

7

8