Set the Automatic Flush Cycle Timing
•
Use DIP 1 and DIP 2 to configure how often
TrueSTEAM will automatically flush the tank.
Timing for the automatic flush is based on hours of
active heating element time.
•
The home’s water hardness determines how often
automatic flushing should be performed.
•
The automatic flush timing can be changed any
time after installation by setting the DIP 1 and
DIP 2 positions, as shown at left.
See “Automatic
Cleaning Cycle” on page 46 for a description of the
automatic flushing process.
6
5
4
3
2
On
Off
1
6
5
4
3
2
1
6
5
4
3
2
1
6
5
4
3
2
1
On
Off
On
Off
For water that is filtered through
the Honeywell RO Filter System.
(30 hour flush)
For hard water without
a softener or filter.
(8 hour flush)
For water that is put through
a softener before
entering TrueSTEAM.
(20 hour flush)
For soft water without
a softener or filter.
(12 hour flush)
On
Off
M29614
If water hardness is in range 1:
Honeywell recommends using the
polyphosphate filter (sold separately).
Proceed to “Water Supply and Drain
Connections” on page 13.
M29602
If water hardness is in range 2:
Honeywell recommends using the RO Filtration
system (sold separately).
Note: If the RO Filtration System is not used, set the homeowner’s
expectation that additional cleaning beyond once per season will
be necessary.
Proceed to “Water Supply and Drain
Connections” on page 13. See “Appendix F:
Reverse Osmosis Filter” on page 23 to install
the filter.
M29661
TrueSTEAM Humidification System 69-2285—01