Honeywell HC60NG Installation And Operation Manual Download Page 4

Overview 

 

2. Overview 

The room unit HCW 80 is used for intelligent room 
temperature control in combination with the relay module 
HC60NG. It can be used to control gas and oil boilers, a 
variety of valves and actuators or electrical heating systems. 
No wiring to the room unit HCW 80 is required. 
Because of the simple HCW 80 analogue user interface with 
absolute set point temperature scale the room set point 
temperature can be easily adjusted. 
The room unit and the relay module provide reliable RF 
communication technology on 868 MHz frequency. 

 

 

The HCW 80 and HC60NG are already teached-
in (bounded). They are provided as pre 
configured kit for fast installation (plug and play). 

 

Wireless Room Thermostat

HCW80

Boiler

Relay module

HC60NG

Example radiator control

Zone 1

 

Fig. 1: Application of the wireless room thermostat 

 

2.1.  Pre configured kit Y6630D1007 

· 

1 HCW 80 (room unit) 

· 

1 HC60NG (relay module) 

· 

2 AA batteries, 1.5 V, type LR6 

 

 

The kit Y6630D1007 is provided pre-bounded. 
The room unit HCW 80 is already assigned to the 
relay module HC60NG. The teach-in is not 
required in this kit. 

 
2.2.  Single provided devices 

 

Single provided devices must be teached-in as 
described in section “5 Teach-in (single devices 
only)”. 
Teach-in means the HCW 80 and HC60NG must 
be RF bounded for communication. 

 

3. Installation 

 

3.1.   Installation relay module HC60NG 

 

 

Fig. 2: Positioning the relay module HC60NG 

 

 

Follow the installation diagrams to install and connect the 
power supply to the relay module HC60NG. 

 

 

1

1

2

 

Fig. 3: Opening the housing cover 

 
 

1

2

 

Fig. 4: Removing the terminal covers 

 
 

> 7 mm 

Æ

< 7 mm 

Æ

 

Fig. 5: Connecting the relay module to the power supply 
 

Summary of Contents for HC60NG

Page 1: ...Y6630D1007 Wireless Room Thermostat Installation and Operation ...

Page 2: ......

Page 3: ...6 EC Waste Electrical and Electronic Equipment directive 9 1 General safety instructions 1 1 Commissioning the relay module HC60NG Danger Danger to life through electric shock Contacts that are open are live Ensure that the device is de energised Have all the work carried out by authorised qualified personnel Observe the valid local regulations during the installation WARNING Insufficient data tra...

Page 4: ...Boiler Relay module HC60NG Example radiator control Zone 1 Fig 1 Application of the wireless room thermostat 2 1 Pre configured kit Y6630D1007 1 HCW 80 room unit 1 HC60NG relay module 2 AA batteries 1 5 V type LR6 The kit Y6630D1007 is provided pre bounded The room unit HCW 80 is already assigned to the relay module HC60NG The teach in is not required in this kit 2 2 Single provided devices Single...

Page 5: ...local wiring regulations Observe ambient temperature and current limits see HC60NG wiring label a Burner direct control b Combi boiler c Zone valve d Electric heater e Thermal actuator f Zone valve g Electric actuator h Cooling device Fig 7 Wiring schemes 1 2 2 Fig 8 Closing the terminal and housing cover ...

Page 6: ...e room unit HCW 80 Place the room unit HCW 80 at the installation site Remove the housing cover of the room unit HCW 80 see Fig 10 1 2 Fig 10 Removing the housing cover Mark the drill holes according to the drilling template see Fig 11 Fig 11 Drilling scheme measurements in mm Drill the holes Screw on the room unit Insert the supplied AA batteries with the correct battery polarity see Fig 12 Fig 1...

Page 7: ...odule HC60NG Press and hold the teach in button of the HC60NG for 5 sec to enter into the teach in mode The red LED flashing at 0 5 sec ON 0 5 sec OFF confirms the teach in mode has been entered Press the teach in button of the HCW 80 to send the binding signal to the HC60NG The red LED of the HC60NG is switched OFF to confirm a successful teach in operation The teach in mode is terminated automat...

Page 8: ... 15 the pins are inserted so that the adjustment dial can only be adjusted in the range of 19 C to frost protection lower limit and 19 C to 30 C higher limit around the value 19 C Turn the adjustment dial clockwise until it stops Check whether the adjustment dial is in the position shown in Fig 14 If appropriate put the adjustment back in rotated by 180 until it has the position shown Turn the adj...

Page 9: ...wall box mounting right an bottom RF RF operation band ISM 868 0 868 6 MHz 1 duty cycle RF communication range 30 m in a residential building environment RF communication technology Short high rate transmissions to minimise air time and avoid collisions Blocking immunity Receiver class 2 ETSI EN300 220 1 version 1 3 1 RF binding method Factory pre bound with the room unit HCW 80 kit Y6630D1007 onl...

Page 10: ......

Page 11: ......

Page 12: ...Armaturen Robinetterie Rubinetterie Bernstrasse 36 CH 4663 Aarburg Oftringen Telefon 062 787 70 00 Fax 062 787 70 01 info robinex ch www robinex ch ROBINEX AG SA ...

Reviews: