Honeywell HC60NG Installation And Operation Manual Download Page 3

General safety instructions 

 

Contents 

1.

 

General safety instructions .................................... 3

 

1.1.

 

Commissioning the relay module HC60NG........... 3

 

2.

 

Overview ............................................................... 4

 

2.1.

 

Pre configured kit Y6630D1007............................. 4

 

2.2.

 

Single provided devices......................................... 4

 

3.

 

Installation ............................................................. 4

 

3.1.

 

Installation relay module HC60NG ........................ 4

 

3.2.

 

Installation room unit HCW 80............................... 6

 

4.

 

Checking ............................................................... 7

 

4.1.

 

System check ........................................................ 7

 

4.2.

 

Radio transmission check...................................... 7

 

5.

 

Teach-in (single devices only) ............................... 7

 

5.1.

 

Assignment to the relay module HC60NG............. 7

 

5.2.

 

Failed teach-in....................................................... 7

 

6.

 

Communication loss .............................................. 7

 

7.

 

Factory reset of relay module HC60NG................. 7

 

8.

 

Particular features of the room unit HCW 80......... 8

 

8.1.

 

Operation............................................................... 8

 

8.2.

 

Limiting the adjustment range ............................... 8

 

8.3.

 

Fixed control parameters....................................... 8

 

9.

 

Changing batteries ................................................ 8

 

10.

 

Appendix ............................................................... 9

 

10.1.

 

Help with problems................................................ 9

 

10.2.

 

Specifications HCW 80.......................................... 9

 

10.3.

 

Specifications HC60NG......................................... 9

 

10.4.

 

Device and function definition in accordance 
with EN 60730-1.................................................... 9

 

10.5.

 

WEEE directive 2002/96/EC – Waste Electrical 
and Electronic Equipment directive ....................... 9

 

 

1. General 

safety 

instructions 

1.1.  Commissioning the relay module 

HC60NG 

Danger 

 

Danger to life through electric 
shock! 

Contacts that are open are live. 

 

Ensure that the device is de-
energised. 

 

Have all the work carried out by 
authorised qualified personnel. 

 

Observe the valid local regulations 
during the installation. 

 

WARNING 

 

Insufficient data transfer! 

Interference of the relay module 
HC60NG in the device through metallic 
objects or further frequency devices. 

 

Mount the device with a distance of at 
least 30 cm to metallic objects such 
as wall boxes or boiler housings 
according to the DECT standard, etc. 

 

Do not mount on metal wall boxes. 

 

WARNING 

 

Damage to the device! 

Short-circuiting through humidity and 
moisture. 

 

Mount the device at a site that is 
protected against humidity and 
moisture. 

 

WARNING 

 

Damage to exposed components! 

Destruction of the electronic 
components through electrostatic 
discharges. 

 

Do not touch the components. 

 

Touch an earthed piece of metal to 
discharge static electricity from your 
body. 

 

Summary of Contents for HC60NG

Page 1: ...Y6630D1007 Wireless Room Thermostat Installation and Operation ...

Page 2: ......

Page 3: ...6 EC Waste Electrical and Electronic Equipment directive 9 1 General safety instructions 1 1 Commissioning the relay module HC60NG Danger Danger to life through electric shock Contacts that are open are live Ensure that the device is de energised Have all the work carried out by authorised qualified personnel Observe the valid local regulations during the installation WARNING Insufficient data tra...

Page 4: ...Boiler Relay module HC60NG Example radiator control Zone 1 Fig 1 Application of the wireless room thermostat 2 1 Pre configured kit Y6630D1007 1 HCW 80 room unit 1 HC60NG relay module 2 AA batteries 1 5 V type LR6 The kit Y6630D1007 is provided pre bounded The room unit HCW 80 is already assigned to the relay module HC60NG The teach in is not required in this kit 2 2 Single provided devices Single...

Page 5: ...local wiring regulations Observe ambient temperature and current limits see HC60NG wiring label a Burner direct control b Combi boiler c Zone valve d Electric heater e Thermal actuator f Zone valve g Electric actuator h Cooling device Fig 7 Wiring schemes 1 2 2 Fig 8 Closing the terminal and housing cover ...

Page 6: ...e room unit HCW 80 Place the room unit HCW 80 at the installation site Remove the housing cover of the room unit HCW 80 see Fig 10 1 2 Fig 10 Removing the housing cover Mark the drill holes according to the drilling template see Fig 11 Fig 11 Drilling scheme measurements in mm Drill the holes Screw on the room unit Insert the supplied AA batteries with the correct battery polarity see Fig 12 Fig 1...

Page 7: ...odule HC60NG Press and hold the teach in button of the HC60NG for 5 sec to enter into the teach in mode The red LED flashing at 0 5 sec ON 0 5 sec OFF confirms the teach in mode has been entered Press the teach in button of the HCW 80 to send the binding signal to the HC60NG The red LED of the HC60NG is switched OFF to confirm a successful teach in operation The teach in mode is terminated automat...

Page 8: ... 15 the pins are inserted so that the adjustment dial can only be adjusted in the range of 19 C to frost protection lower limit and 19 C to 30 C higher limit around the value 19 C Turn the adjustment dial clockwise until it stops Check whether the adjustment dial is in the position shown in Fig 14 If appropriate put the adjustment back in rotated by 180 until it has the position shown Turn the adj...

Page 9: ...wall box mounting right an bottom RF RF operation band ISM 868 0 868 6 MHz 1 duty cycle RF communication range 30 m in a residential building environment RF communication technology Short high rate transmissions to minimise air time and avoid collisions Blocking immunity Receiver class 2 ETSI EN300 220 1 version 1 3 1 RF binding method Factory pre bound with the room unit HCW 80 kit Y6630D1007 onl...

Page 10: ......

Page 11: ......

Page 12: ...Armaturen Robinetterie Rubinetterie Bernstrasse 36 CH 4663 Aarburg Oftringen Telefon 062 787 70 00 Fax 062 787 70 01 info robinex ch www robinex ch ROBINEX AG SA ...

Reviews: