background image

 

 

 

10 

A double beep is played and all LEDs light on. 

2.  Enter the master code or present the master tag. 

A high beep is played and all status LEDs start flashing. 

3.  Enter the code for the new user. A high beep is played. 

4.  Re-

enter new user’s code. A high beep is played. 

The programming mode ends automatically. 

5.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

To 

disable a user’s code: 

To disable a use

r’s code and keep the TAG only: 

1. 

Press and hold the user number “0 to 9” key for 3 seconds (1 
is the master). 

A double beep is played and all LEDs light on. 

2.  Enter the master code or present the master tag. 

A high beep is played and all status LEDs start flashing. 

3.  Change the code to 0000 (or 000000 if 6 digits). 

4.  Re-enter the code 0000 (or 000000 if 6 digits). 

A high beep is played. 

5.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

To disable a user: 

1.  Press and hold us

er number “0 to 9” key for 3 seconds. 

Note

: it is not possible to disable the master user. 

A double beep is played and all status LEDs light on. 

2.  Enter the master code or present the master tag. 

A high beep is played and all status LEDs start flashing. 

3.  Press the 

 key to disable the user. 

The programming mode ends automatically. 

4.  After a few seconds, a double beep is played and all status 

LED stop flashing. 

Summary of Contents for GKP-S8M

Page 1: ...Wireless Keypad GKP S8M User manual ...

Page 2: ...io frequency and will in no way endanger the user Contents 1 Introduction 3 Arming using your code or tag 4 Arming with a fault 5 Disarming using your code or tag 5 Resetting the system after an alarm 6 Incorrect code protection 6 Personal attack 6 Duress code 7 Switch on off receivers 7 Remote Maintenance optional 7 User Programming functions 8 Indicator lights 12 Keypad tones 13 Maintenance and ...

Page 3: ...2 ANNEX A 16 Indicator lights if keypad installed with PMI panels 16 Arming with a fault if keypad installed with PMI panels 17 ...

Page 4: ...ader located next to the symbol the keypad also features an integrated siren as a deterrent and 4 LEDs to inform you on system status KEYPAD If keypad installed with CMI HMI Sucre Box panels Refer to Annex A if keypad installed with PMI panels TAG Siren output System armed LED LED 1 Intruder alarm LED 2 Total set arming key Tag reader area S O S keys Partial set arming key Tamper alarm LED 4 Syste...

Page 5: ...er fault is signalled on arming disarm the system before checking all the doors and windows equipped with contacts The zone set arming is completed automatically at the end of the delay depending on your system configuration Notes Always make sure that your Total arming request is followed by the arming tone Holding the TAG less than 1 minute in front of the keypad will not reverse the status If a...

Page 6: ...leted at the end of the delay If keypad installed with CMI HMI Sucre Box panels Refer to Annex A if keypad installed with PMI panels Disarming using your code or tag To enable you to get to the keypad without triggering an alarm your installer may have programmed an entry delay To disarm your system Enter a valid code or present a programmed TAG The disarming tone is emitted by the panel and keypa...

Page 7: ...lashing slowly If LED 4 is flashing quickly on your keypad a confirmed alarm has occurred and a reset must be performed by your alarm company you cannot operate the system Call the operator If keypad installed with CMI HMI Sucre Box panels Incorrect code protection Important If you enter five successive incorrect codes or present 5 invalid tags consecutively the keypad will be blocked for 5 minute...

Page 8: ...s such as smart plugs from the keypad To switch a receiver on off 1 Press the key to switch the selected receiver on or the key to switch the selected receiver off 2 Select the desired receiver by pressing a key corresponding to the receiver number 0 to 9 0 corresponds to receiver number 10 A high beep is played if the receiver is driven successfully otherwise a low beep is played Remote Maintenan...

Page 9: ...aster code master user 1 USER FUNCTIONS To adjust the volume of the beep 1 Press and hold the and keys simultaneously more than 2 seconds to enter user programming mode A double beep is played and all LED light on 2 Keep pressing the key to select the device that you wish to adjust each device will emit a beep when it is selected Example If you want to adjust the beep level for device 2 press the ...

Page 10: ...ew seconds a double beep is played and all status LED stop flashing MASTER USER FUNCTIONS To associate a TAG to a user 1 Press and hold the user number 0 to 9 key for 3 seconds 1 is the master A double beep is played and all LEDs light on 2 Enter the master code or present the master tag A beep is played and all status LEDs start flashing 3 Present a new TAG The programming mode ends automatically...

Page 11: ...ll LEDs light on 2 Enter the master code or present the master tag A high beep is played and all status LEDs start flashing 3 Change the code to 0000 or 000000 if 6 digits 4 Re enter the code 0000 or 000000 if 6 digits A high beep is played 5 After a few seconds a double beep is played and all status LED stop flashing To disable a user 1 Press and hold user number 0 to 9 key for 3 seconds Note it ...

Page 12: ...ntering prog Command Selection End Adjust beep volume for 2 sec Select the device several times Select level 1 to 7 Enable Chime for 2 sec Disable Chime for 2 sec Master User Programming Mode Summary Procedure Entering prog Authorization Selection End Assign TAG User key 0 9 for 3 sec Master code or master TAG Present TAG Changing Code User key 0 9 for 3 sec Master code or master TAG New user s co...

Page 13: ...ckly A confirmed alarm is in memory and requires a remote reset Please call your monitoring operation at the alarm company Off No intruder alarm LED 3 indicator system fault On A system fault is occurring on set System faults include battery or power failure supervision fault GSM GPRS failure or radio Jamming smoke sensor failure Please contact your alarm company if this indication persists Flashi...

Page 14: ...uous beep Total and annex set arming beeps continue until final exit door is closed Partial set arming beeps continue for 30 seconds until partial set is armed ARMING COMPLETE After closing the final door Three fast beeps When closing the final exit door confirms that the system is armed ENTRY DELAY Upon entry One double beep per second followed by faster double beep for 10s and then 2s continuous...

Page 15: ...e at room temperature Dispose of old batteries in containers provided for this purpose Avoid prolonged exposure to siren emissions Do not paint or paper over the components Do not try to open or move the components they are tamper protected and some of them may cause electric shocks Replacing the battery The System Fault LED indicates that the keypad battery may need to be replaced The keypad will...

Page 16: ...Y REMOVED BY HAND CARE SHOULD BE USED TO ENSURE THAT THE BATTERY TERMINALS ARE NOT SHORTED NOR THE BATTERY DAMAGED DURING THE REMOVAL PROCESS DISPOSE OF DEPLETED BATTERIES BY COMPLYING WITH APPLICABLE NATIONAL AND LOCAL REGULATIONS IN THE EVENT OF THE BATTERY BEING DAMAGED USE PERSONAL PROTECTIVE EQUIPMENT TO REMOVE IT IMMEDIATELY AND DISPOSE OF IT IN A SAFE MANNER REFER TO THE BATTERY MANUFACTURE...

Page 17: ... activation Flashing An intrusion occurred during the partial or annex activation of the system The indicator remains on until the next activation Off No memorized alarm LED 3 indicator perimetric fault Flashing A window or a door protected by a magnetic contact is open It flashes until the window or door has been closed Off No perimetric fault LED 4 indicator system fault On Activation of a techn...

Page 18: ... tone Honeywell Security Group 1198 Avenue du Docteur Maurice Donat BP 1219 06254 MOUGINS CEDEX Tel 33 0 4 92 94 29 50 Fax 33 0 4 92 94 29 60 www honeywell com security fr 800 20982 A 2015 Honeywell International Inc Honeywell is a registered trademark of Honeywell International Inc All other trademarks are the properties of their respective owners All right reserved ...

Reviews: