Audio Pack 0

The micro-DAU is fitted with Audio Pack 0. As we have Audio Pack 0 post September 2010 and
Audio Pack 1 pre September 2010 it is important to ensure during commissioning there is consistency of
Audio Packs throughout a system.

* These are legacy default Evacuate and Alert messages of Audio Pack 1.

#

These tones and messages are applicable for Vigilon Compact VA panel ONLY

.

No.

Type of message

Voice

Message

1

DAU Test

Male

The voice alarm volumes are being adjusted there is no need to take
any action.

2

Alert

(default - Emergency 1)

Female

An incident has been reported in this building please await further
instructions.

3

Evacuate

(default - Emergency 2)

Male

This is a fire alarm please leave the building immediately by the
nearest available exit.

4

Bomb

(default - Emergency 3)

Female

Attention please this is an emergency please leave the building by
the nearest available exit.

5*

Alert
(alternative)

Female

Your attention please, the fire alarm has been activated in another
area, please remain where you are and await further instructions..

6*

Evacuate
(alternative)

Male

Attention please, attention please, this is an emergency, please
leave the building by the nearest available exit. Do not use the lifts
or escalator.

7

Gas Carbon Monoxide

Male

May I have your attention please, may I have your attention please,
excessive carbon monoxide levels have been detected, please leave
the area immediately by the nearest available exit.

8

Gas Fixed Extinguishant

Male

May I have your attention please, may I have your attention please,
extinguishant gas release imminent, please evacuate the area
immediately by the nearest available exit.

9#

Fire alarm test

(default - Auxiliary 1)

Female

Attention please, attention please, this is the test of the fire and voice
alarm system, there is no need to take any action.

10#

Fire alarm test end

(default Auxiliary 2)

Female

The test of the fire and voice alarm system has now been completed.

11#

Coded message

Female

Would Mr Sands please report to reception.

12#

Class change

Female

Class change

13#

Not used

14#

Stand down

(default - Auxiliary 3)

Female

May I have your attention please, the cause of the alarm has been
investigated and the system reset. There is no cause for concern.
Thank you.

15#

Navy radiological attack

-

Beep beep beep (950Hz 80ms beep every 420mS)

16#

Navy bandit attack

-

Beep beep beep (950Hz 50ms beep every 80mS)

17

Nursery Rhyme 1

Boys & Girls

18

Nursery Rhyme 2

Twinkle Twinkle

19

Factory test

-

Frequency sweep (300Hz to 10KHz in 3s)

Attention tone

No

Description of tone

No

Description of tone

1

Nee Naw x 8

6

Pulse

2#

Two tone (Bing bong)

7

Continuous

3#

Four bing tones - ascending

8

Bong

4

Four bing tones - descending

9

Chopin

5

Bell

10

Jingle of bells

Commissioning information

micro Distributed Amplifier Unit

2

4188-781 issue 6_Part 2_ 08/10_micro DAU commission

Summary of Contents for GENT COMPACT-DAU

Page 1: ... powered by the control panel via a loop circuit The micro DAU is supplied in two assemblies Backbox with front cover micro DAU PCB assembly Parts in the spares pack Quantity Allen key 1 M4 Socket head screw for door 2 Cable entry bungs 3 Screw PCB fixing 1 Washer use with PCB fixing screw 1 Open the outer door using the allen key Backbox Flush fixing the micro DAU The micro DAU can be flush fixed...

Page 2: ...to time and make changes to the content hereof without obligation to notify any person of such revisions of changes Hamilton Industrial Park Waterside Road Leicester LE5 1TN UK Website www gent co uk Telephone 44 0 116 246 2000 Tech Support www gentexpert co uk Fax UK 44 0 116 246 2300 4188 781 issue 6_Part 1_08 10_micro DAU install by Honeywell At the end of their useful life the packaging produc...

Page 3: ...operate with any of the above conditions in any combination A A and B B Speaker circuits These terminals accept the connection of two speaker circuits Each speaker circuit can have up to 5 x 64ohms speakers 4188 781 issue 6_Part 2_ 08 10_micro DAU commission 1 Commissioning information micro Distributed Amplifier Unit COMPACT DAU by Honeywell P4 L1 01 L2 02 Audio Status I R SENSOR LOOP P1 N01 C1 N...

Page 4: ...tention please excessive carbon monoxide levels have been detected please leave the area immediately by the nearest available exit 8 Gas Fixed Extinguishant Male May I have your attention please may I have your attention please extinguishant gas release imminent please evacuate the area immediately by the nearest available exit 9 Fire alarm test default Auxiliary 1 Female Attention please attentio...

Page 5: ...in the building whilst this report is being investigated please remain at your workplace 6 Evacuate alternative Male Ladies and gentlemen due to unforeseen circumstances we are required to evacuate the building please leave the building immediately by the nearest available exit 13 Gent Limited advertisement Female Ladies and gentlemen this speech message is produced by Gent Limited s Vigilon Compa...

Page 6: ...ted Amplifier Unit 4 4188 781 issue 6_Part 2_ 08 10_micro DAU commission L 1 0 1 L 2 0 2 L1 0V Mains Distributed Amplifier unit L2 0V VIGILON COMPACT VOICE ALARM PANEL Master Control Board P7 L1 0V L2 0V L1 0V L2 0V DEVICE LOOP CIRCUIT 1 Note The 0V terminals in the device terminal plate are electrically connected together LOOP 2 LOOP 1 P14 PB1 L1 01 L2 02 P13 P12 O A O B I A I B AUDIO LOOP 1 O A ...

Page 7: ...er circuits fast 8 quick flashes blinks every 1s slow 1 slow flash every 0 5s On 0 5s Off every 1s Amplifiers and Speaker circuits healthy CAL micro DAU PCB Press the CAL button on micro DAU PCB to recover from Amplifier fault If the amplifier is still faulty then these indications will reappear Fault on Speaker Circuit B slow No Power to micro DAU Quiescent blink micro DAU in Fall back mode fast ...

Page 8: ...P2 P9 LD1 CAL P5 P11 DISCHARGE LED P6 A B LOCAL AUDIO P17 P17 NVM protect Enabled NVM protect Disabled After the micro DAU is configured insert the NVM link across pins 1 2 of P17 to preserve the data at the unit When the micro DAU is being configured ensure the NVM link is NOT fitted across pins 1 2 of P17 NVM Link DISCHARGE LED LD4 Normally OFF Ensure the SPRING is fitted to Switch SW2 CAL FAULT...

Page 9: ...utes You may also hear a popping sound from the speakers during calibration Audio Status Circuit B fault Circuit A fault 3 m m a xi m u m ra n g e Remote Control Trouble shooting If the remote control fails to operate in close proximity to the indication aperture on micro DAU then a possible cause may be the battery Replace the battery in the remote control micro DAU Audio Status Circuit B fault C...

Page 10: ...emote control You are now in BGM background music volume adjust mode ƒ Press and hold the Power button to save the settings made and release the button after about 2 seconds If PA or VA then go to step 5 Press the button to allow mode change Press or button to change from BGM to PA to VA volume adjust mode The micr DAU LEDs indicate which mode has been selected Press the button to accept the mode ...

Page 11: ...ing on the Background music system How to enable or disable Background music or PA The background music and PA can be enabled or disabled to do this press the Menu On Off button and then select Control followed by Enable Disable and then momentarily press etc and select Audio now select either PA or Music followed by Enter 4188 781 issue 6_Part 2_ 08 10_micro DAU commission 9 micro Distributed Amp...

Page 12: ...uld be disposed of via a suitable recycling centre and in accordance with national or local legislation Gent by Honeywell reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions of changes Hamilton Industrial Park Waterside Road Leicester LE5 1TN UK Website www gent co uk Telephone 44 0 116 246...

Reviews: