background image

 

Installation Guide and Operating Manual // Model FS20X™ Series 

 

 

 

 

 

Honeywell    

 

28 

Drawings  

(continued)

 

4.7.3 Hazardous Location Detector Markings 

 
Class I, Division 1, Groups A, B, C & D; Class II, Division 1 Groups E, F & G; Class III; Class I, Zone 1 AEx d /Ex d IIC 
Hazardous Locations.  

 

ATEX IECEx CertificationClass I, Zone 1, Ex db IIC (T4-T6) and Ex tb IIIC (T4-T6). 
 
ATEX Certification FM14ATEX0058X 
IECEx Certification FMG 14.0027X 
Ex db IIC T6….T4 Gb 
Ex tb IIIC T135

̊

C Db IP66 

II 2 G Ex db IIC T6…T4 Gb 
II 2 Ex tb IIIC T135

̊

C IP66 

 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

  

 

 

Part 

Number 

Model 

Number 

Material 

Background  

Color 

Text Color 

mA 

T4 

T5 

T6 

LB-6093-

037 

FS20X 

0.020' Al  1100-Hl4 

Black 

White 

150 

-40C to +110C 

-40C to 

+75C 

-40C to 

+60C 

LB-6093-

038 

FS20X 

0.020'  316  

Stainless  Steel 

Polished 

Black 

150 

-40C to +110C 

-40C to 

+75C 

-40C to 

+60C 

LB-6093-

039 

FS20X 

0.020' Al  1100-Hl4 

Black 

White 

150 

-40C to +110C 

-40C to 

+75C 

-40C to 

+60C 

LB-6093-

040 

FS20X 

0.020'  316  

Stainless Steel 

Polished 

Black 

150 

-40C to +110C 

-40C to 

+75C 

-40C to 

+60C 

 

 

Label Configurations

 

P/N 

Model 

No. 

Full Description 

Material 

IR/UV Type 

LPCB Number  

CPR Number 

Background 

color 

Text 

Color 

mA T4  T5:  T6: 

LB-
6095-
001 

 

FS20X 

Label, FS20X, ss, with 
FM/Canada/US ATEX, 
IECEX approval 

0.020” 316 
Stainless 
Steel 

WideBand 

IRTM/UV 

1175a/01 

0832-CPR-F0515 

 

Matte 

 

Black 

 

150 

-40ºC 

to 

+110ºC 

-40ºC 

to 

+75ºC

 

-40ºC 

to 

+60ºC

 

LB-
6095-
003 

 

FS24X-

Label, FS24X-9, ss, with 
FM/Canada/US ATEX, 
IECEX approval 

0.020” 316 
Stainless 
Steel 

QuadBand 

Triple IRTM 

1175a/02 

0832-CPR-F0516 

 

Matte 

 

Black 

 

150 

-60ºC 

to 

+110ºC 

-60ºC 

to 

+75ºC

 

-60ºC 

to 

+60ºC

 

Summary of Contents for FS20X Series

Page 1: ...Manual FSX Fire and Flame Detectors Model FS20X Series FS20X WideBand IR UV Multi Spectrum Infrared Ultraviolet Electro Optical Multi Spectral Digital WideBand IR Sensor with Ultraviolet Phototube Radiant Energy Fire and Flame Detector ...

Page 2: ...cal Path Integrity CM1 CM1 A DartLogic FireLogic Fire Signature Analysis FireBusI FireBusII FirePic FirePicII FirePicIII FirePix FirePicture FSC Fire Sentry Corporation Fire Sentry Corp FSX All FSX Nomenclature Variations such as FS2 FS2X FS3 FS3X FS4 FS4X FS5 FS5X FS6 FS6X FS7 FS7X FS8 FS8X FS9 FS9X FS10X FS10X FS11 FS11X FS12 FS12X FS14 FS14X FS15 FS15X FS16 FS16X FS17 FS17X FS18 FS18X FS19 FS19...

Page 3: ...8 U2 3 Detector Connections 10 U2 4 Installation Practices 12 U2 5 Start Up and Commissioning 14 SECTION 3 OPERATION 16U U3 1 Principle of Operation 16 U3 2 Configuring the Detector 16 U3 3 Normal Operation 18 U3 4 Alarm Condition 18 U3 5 Fault Conditions 19 U3 6 LED Status Indicators 18 U3 7 Maintenance 19 SECTION 4 APPENDIX 20U U4 1 Warranty Information 20 U4 2 Product Variations 21 U4 3 Digital...

Page 4: ...s module puck is enclosed in a replaceable black hard anodized aluminum puck that provides superior ruggedness handling ease of installation and protection against EMI RFI Figure 1 1 FS20X Detector Shown with Copper Free Aluminum Housing FS20X Detector Field Connectors The field connections feature two 2 connector choices for the installer 1 A removable ten 10 pin screw terminal connector J2 for h...

Page 5: ... Fire Alarm 20 0 mA 0 6 mA Verified Fire Alarm Screw Terminal Wire Sizes 12 AWG to 22 AWG 2 50 mm to 0 762 mm Use stranded conductors UnotU solid core 1 2 3 Environmental Specifications Operating Temperature Standard 40 F to 185 F 40 C to 85 C Operating Humidity Range 0 to 95 RH 100 RH condensing for short periods of time Storage Temperature 67 F to 221 F 55 C to 105 C 1 2 4 Performance Specificat...

Page 6: ...ries Honeywell 4 1 2 6 Flame Performance Certification See Section 4 7 3 on Pages 31 Agency Standard Certificate Notes LPCB EN 54 10 2002 A1 2005 1175a 01 Sensitivity settings Very High High Medium EN 54 10 Class 1 CPR EN 54 10 2002 A1 2005 0832 CPR F0515 ...

Page 7: ...tandard Built In Automatic Through the Lens Self Test Monitors window lens obscuration and checks the operation of the Detector s Sensor Array and Electro Optical Electronics Module with Built In IR FS19X FS20X and UV FS20X Self Tests Anodized Removable Detector Aluminum Module Puck Rugged superior protection against EMI RFI and handling plus easier field installation and replacement Three Separat...

Page 8: ...as Collection Facilities Gas Processing Plants Gas Turbine Enclosures Gasoline Loading Terminals LNG Storage Distribution LPG Storage Distribution Cogeneration Plants Crude and Product Tank Farms Aerosol Filling Facilities Commercial and Military Aircraft Hangars Engine Test Cells Marine Engine Rooms Marine Terminals Paint and Solvent Storage Power Plants Product Storage Terminals Rail and Truck L...

Page 9: ...el Mount designed for the FSC Detector housing The adapter plate with the two 2 screw holes facing away is attached to the base of the Detector see Figure 2 2 The mounting plate with the four 4 screw holes facing towards is used for mounting the SM4 to a solid surface Each adjustment increment along an axis is calibrated to 10 For single axis adjustments the center section need not be installed 6 ...

Page 10: ... al electronics uld be cleane re 2 5 tector s senso or IPA sparin ble parts insid tampered with protection pr puck to the Detector Mod Guide and Ope Figu s on the front module puck d following th or windows o gly and a cott de the Detect h all warranti rocedures wh Detector U ule puck fro erating Manua ure 2 4 t of the k If touched he instructions n the puck it ton swab tor puck If th es are voide...

Page 11: ...set screw on the enclosure lid see Figure 2 6 Figure 2 6 5 Turn counterclockwise CCW to unscrew the enclosure lid see Figure 2 7 Figure 2 7 6 Loosen the three captive screws on the Detector Module puck see Figure 2 8 Figure 2 8 CAUTION Disconnect power before unscrewing the Housing Lid ...

Page 12: ...faces see Figure 2 10 For relay configurations use the ten 10 pin plug J2 and its connector For digital and analog configurations use the six 6 pin plug J1 and its connector J2 Connector Figure 2 10 Detector Module puck rear view J1 Connector Pin Connection Pin Connection 1 Auxiliary NC 1 DC Return 2 Auxiliary NO 2 RS 485 A 3 Auxiliary COM 3 RS 485 B 4 Alarm NC 4 24 VDC 5 Alarm NO 5 4 20mA Source ...

Page 13: ...Installation Guide and Operating Manual Model FS20X Series Honeywell 11 Figure 2 11 Recommended Wiring Configurations ...

Page 14: ...ower is turned UOFFU before connecting the Detector 2 Avoid wire splices whenever possible If wire splices are required solder and properly insulate them Good wiring practices simplify installation improve reliability and facilitate maintenance 3 For applications requiring analog digital communications refer to Section 3 2 2 4 Installation Practices For installations in a Hazardous Classified Area...

Page 15: ...3 2 for detailed descriptions U Before applying 24 VDC power to the Detector make sureU 1 Wire connections are correct Section 2 3 Each wire must be stripped properly to the correct length loose wire strands must be removed and each wire must be securely and firmly screwed clockwise in the connector 2 If using conduit ensure a proper conduit seal appropriate for the area classification has been in...

Page 16: ...re used Also since most detectors are installed in a fire alarm system this is the only method to test the complete fire alarm system ensuring all the system wiring and cabling and system control panel are properly installed Additionally using an external test lamp eliminates the following detector conditions 1 The fire or flame detector s viewing lens being covered up such as paint paint over spr...

Page 17: ...ly move the Test Lamp s boresight to ensure the Detector receives its full intensity UNOTE Practicing this technique may help to optimize testing of the FSX DetectorsU Sections 3 6 and 4 4 The Detector s ALARM LED will illuminate usually within three 3 to ten 10 seconds Also the ALARM Relay outputs will activate and the 4 20 mA analog output will increase to 20 mA 0 6 mA If the Detector fails to r...

Page 18: ...ideBand IR and UV algorithms for over a quarter of a century since 1981 These patented algorithms perform real time DSP and precisely analyze the signals in high resolution frequency and time domains This decision making process involves thousands of real time calculations every second Honeywell Analytics FSX Detectors use solid state high speed quantum sensors not heat sensors such as pyroelectri...

Page 19: ...ry default settings are shown with a gray background Energized ON De Energized OFF Fault Relay SW2 8 If the Fault Relay to set to De Energizied the Detector will not report any faults due to loss of input power to the Detector Energized ON De Energized OFF Analog and digital outputs are available in addition to relay outputs Select from two 2 analog outputs or two 2 digital outputs using a ten 10 ...

Page 20: ...tion is defined as the Detector with 24 VDC applied and no Alarm or Fault conditions are present If one of the 4 20 mA options are selected Table 3 1 the current sink or source will be 4 0 mA 0 6 mA Only the current source mode has been certified to the EN54 10 standard Figure 3 4 Green LED Location 3 5 Alarm Condition When an Alarm condition occurs the Red LED will turn ON factory setting with th...

Page 21: ...test of the entire fire detection system should be performed periodically depending on the application Additionally semi annual or quarterly testing should be performed using the correct Honeywell Analytics Test Lamp to ensure the integrity of the entire fire protection system The optical window lens of the Model FS20X Detector should be clean in order to ensure the Detector is operating properly ...

Page 22: ... of use loss of time inconvenience commercial loss lost profits or savings or other incidental special or consequential damages arising out of or in connection with the use or inability to use such product to the full extent such may be disclaimed by law THIS WARRANTY DOES NOT COVER 1 Defects or damage resulting from use of the Product s in other than its normal and customary manner 2 Defects or d...

Page 23: ...ss I Zone 1 AEx d Ex d IIC Ex db IIC Ex tb IIIC IR and UV Self Tests Approvals FM cFM ATEX IECEx LPCB EN 54 10 2002 Model Numbers FS20X IR2 UV UV IR Self Test Enclosure Types 0 No Enclosure Module Only 1 Aluminum NPT Conduit Entries 2 316 Stainless Steel NPT Conduit Entries 3 Aluminum 25 mm Conduit Entries 4 316 Stainless Steel 25 mm Conduit Entries Options 0 Enclosure Assembly Only Top Base 1 Det...

Page 24: ...outputs i e relays 4 to 20 mA open collectors etc function properly Internal Detector testing and window lens cleanliness testing cannot insure the Detector is aimed properly that its view of the fire scene has not been blocked by something such as a newly installed pipe or duct storage box parked vehicle etc and its alarm outputs are functioning properly For calibrated testing in compliance with ...

Page 25: ...onds IPA 6 in X 6 in 15 2 cm X 15 2 cm 87 ft 26 5 m 3 Seconds JP4 6 in X 6 in 15 2 cm X 15 2 cm 75 ft 22 9 m 3 Seconds JP8 6 in X 6 in 15 2 cm X 15 2 cm 87 ft 26 5 m 3 Seconds Methane 3 8 in dia 9 5 mm orifice 32 in 0 8 m Plume 70 ft 21 3 m 3 Seconds Methanol 12 in X 12 in 0 3 m X 0 3 m 40 ft 12 2 m 3 Seconds n Heptane 6 in X 6 in 15 2 cm X 15 2 cm 87 ft 26 5 m 3 Seconds Silane 1 32 dia 0 8 mm ori...

Page 26: ... 7 62 meters Modulated Arcwelding 9 feet 9 inches 3 meters Source at 30 feet 9 14 meters Fire at 30 feet 9 14 meters Continuous Arcwelding 9 feet 9 inches 3 meters Source at 30 feet 9 14 meters Fire at 30 feet 9 14 meters Resistive Electric Heater 1 foot 30 48 centimeters Source at 3 feet 91 44 centimeters Fire at 200 feet 60 96 meters Flourescent Lamp 1 foot 30 48 centimeters Source at 3 feet 91 ...

Page 27: ...tallation Guide and Operating Manual Model FS20X Series Honeywell 25 4 7 Drawings 4 7 1 Outline and Dimensions Figure 4 3 Outline Dimesional Drawing for FS20X Figure 4 4 Outline Dimesional Drawing for SM4 ...

Page 28: ...ing for 4 20mA Sourcing Analog Output Figure 4 6 Typical Wiring for 4 20mA Sinking Analog Output NOTES 1 Cable shield must be grounded at one end only at the Control Panel Coil and tape cable shield at the Detector end 2 Set SW3 rotary switch to position one 1 for Source current wiring 3 Set SW3 rotary switch to position zero 0 for Sink current wiring ...

Page 29: ...ault Relay Contacts N O Note 3 Note 2 Note 4 EOL Note 1 Figure 4 8 Typical Relay Output Wiring for Monitoring Alarm and Fault Contacts on a single two wire input NOTES 1 Cable shield must be grounded to Earth Ground at the Control Panel end only Coil and tape the cable shield at the Detector end 2 Alarm relay contacts shown with no power applied Alarm relay is normally De Energized during normal o...

Page 30: ...110C 40C to 75C 40C to 60C LB 6093 038 FS20X 0 020 316 Stainless Steel Polished Black 150 40C to 110C 40C to 75C 40C to 60C LB 6093 039 FS20X 0 020 Al 1100 Hl4 Black White 150 40C to 110C 40C to 75C 40C to 60C LB 6093 040 FS20X 0 020 316 Stainless Steel Polished Black 150 40C to 110C 40C to 75C 40C to 60C Label Configurations P N Model No Full Description Material IR UV Type LPCB Number CPR Number...

Page 31: ...tures and Benefits 5 Fire 2 FireBus II 21 22 H Hazardous Locations 3 14 22 I Installation Practices 12 L LEDs green 18 red 18 yellow 16 18 19 M Maintenance 19 Modbus 16 17 18 19 21 22 Module 2 5 8 10 19 21 Mounting Instructions 7 Multi Spectrum 2 16 N Normal Operation 18 O Opening the Detector 8 10 P Principle of Operation 16 Product Overview 2 Product Variations 21 R radiant energy 2 16 Relay Coi...

Page 32: ... 701 Kolon Science Valley 1 43 Digital Ro 34 Gil Guro Gu Seoul 152 729 Korea Email analytics ap honeywell com Internet These Honeywell websites may be of interest to Industry Solution customers Honeywell Organization URL Corporate www honeywell com Honeywell Analytics www honeywellanalytics com Telephone Contact us by telephone at these numbers Organization Phone Number Americas Honeywell Analytic...

Page 33: ...Installation Guide and Operating Manual Model FS20X Series 1998M0902 Revision C September 2015 2015 Honeywell International Inc ...

Reviews: