Refer to Supplemental Information (next page) for complete descriptions of these installation steps 

 

 

5-051-741-00 Rev. B 

Page 1

 

 

 

FlexGuard

®

 

FG-1625TAS Glassbreak Detector Installation Instructions

 

FG-1625TAS Glassbreak Detector  

1625_001-V2

Tamper Switch

Rear Tamper

Terminal Block

Wire Entry Hole

Mounting Hole

Mounting Hole

Microphone

With Anti-Sabotage
Wire Mesh

LED Indicators

Test Mode Pads

Front Cover

Terminal Block

Cover Screw Location

 

 

Select Mounting Location 

 

Wall Mount 

(Top View)

1625_w

all_mnt-V0

 

 

1625_ceiling_mnt-001-V0

Ceiling Mount: (Side View)

 

 
Test Location w/ 9V Battery 

 

V+

V

9V

9V_001-V0

 

 

Set Sensitivity & LED Configuration 

1625_004-v1

SENS1

SENS2

LATCH

LED

234

1

ON

ON

1

2

3

4

 

 

SENS1 & SENS2 configure sensitivity 

SENSITIVITY APPROXIMATE 

RANGE  

SENS1 SENS2 

MAX 

7.6m  (25 ft) 

OFF OFF 

MEDIUM 

4.6m  (15 ft) 

ON OFF 

LOW 

3m  (10 ft) 

OFF ON 

LOWEST 

1.5m  (5 ft) 

ON ON 

NOTE:  Ranges are approximate and vary with each room’s 
acoustic properties.  Always verify range with a FG-701 
Glassbreak Simulator. 

The LATCH and LED DIP switches configure LED 
indicator behavior. 

SWITCH OFF 

ON 

LATCH 

Red LED lights for 5 
seconds during alarm 

Red LED latches ON when 
detector goes into alarm 

1, 2

 

LED 

LEDs disabled (except for  
power up and test mode

3  

LEDs always enabled 

1  

The timing of the alarm relay is not affected by the latched Alarm LED.  

2  

Reset the Alarm LED by removing/restoring power, or by toggling the 

detector in and out of Test Mode. 

3  

LEDs can be enabled/disabled using FG-701.  

Enable Wall Tamper 

 

Remove plastic tab from rear of detector. 

 

Install wall tamper screw as shown.  

 

Set screw depth to make contact w/ bottom of 
tamper cavity when device is installed 
 
 

1625_005-V0

4.2 mm or 4.8 mm

[#8 or #10]

9.7 mm [.38”]

Max. screw head size

Wire Channel

Breakout Tabs

Wire Channel

Breakout Tabs

 

 

Connect Detector 

Connect detector using 18 to 22 AWG wire, with ends 
stripped approximately 6mm (1/4 in.)  Use the 
appropriate wiring method as shown in these diagrams: 

 

 

V+
V-

NC

C

NO

EOL

TMPR

TMPR

EOL

1625Wiring_001-V1

 

Normally Closed Loop/No EOL Resistor 

 

 

V+
V-

NC

C

NO

EOL

TMPR

TMPR

EOL

1625Wiring_002-V1

 

Normally Open Loop/No EOL Resistor 

 

 

V+
V-

NC

C

NO

EOL

TMPR

TMPR

EOL

1625Wiring_003-V1

 

Normally Closed Loop/With EOL Resistor 

 

 

V+
V-

NC

C

NO

EOL

TMPR

TMPR

EOL

1625Wiring_004-V1

 

Normally Open Loop/With EOL Resistor 

Mount Detector 

 

Place unit over wall tamper screw, if used! 

 

Use mounting holes as template to mark 
ceiling or wall.  

 

Mount detector using appropriate hardware. 
 
 

1625_006-V00

3.5 mm* or 4.2 mm

[#6 or #8]

* 3.5 mm (#6) screws

work best with the

screw retention feature.

 

 
 

 

Test Detector Installation 

 

Enter Test Mode using FG-701 (see Testing the 
Detector on the next page) or manually by shorting the 
Test Mode pads (as below). 
 

TEST

1625_007-V1

234

1

ON

 

 

 
 
Install Cover Screw (optional) 
 

1625_008-V1

2.9 mm (#4) screw,
6 mm (1/4-in.) long

 

 
 

 

 

 