Characteristics
Weight
less the 2.3 kg
Dimensions
200 × 208 × 108 mm
Chemical agent
KO
2
Using temperature
+10°C +35°C
can be used from -5°C to +60°C but chemical reaction
could be slow
Mouth piece material
silicone
Casing material
stainless steel with impact memory
Autonomy
30 min at respiratory rate of 35 l/min
90 min at respiratory rate of 10 l/min
Thermal sponge
yes
Respiratory bag volume
> 6l
Respiratory bag material
High tear resistant
Integrated starter
compressed O
2
Service life
10 years for on-shift operation per day
Maintenance
visual inspection every 6 months
Wearing
on waist
Donning
less than 15 sec
Accessories
goggles
wearing belt
training units
vacuum pump
Approvals
EN 13794: 2002 Type K30 S (30 minutes)
Safety and Health requirements of Directive 89/686/EEC (Personal Protective Equipment)
Ordering information
Oxy-Pro without waist belt, without goggles
1918727
Oxy-Pro without waist belt with goggles
1919315
Training Oxy-Pro (refillable) with goggles without waist belt
1918843
Oxy-Pro waist belt
1910565
Security sealing (sold by 30 pcs)
1564485