Honeywell F200E Product Data Download Page 8

F200E CHARGED-MEDIA AIR CLEANER

68-0238

8

68-0238   G.H.   10-00

Printed in U.S.A. on recycled 
paper containing at least 10% 
post-consumer paper fibers.

Home and Building Control
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 429

Home and Building Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422

Honeywell

Choose better indoor air for your family 
by installing Honeywell solutions. 
You'll enhance your comfort and peace of mind.

Ultraviolet Air Treatment System
Zap
 airborne germs and prevent mold
spore growth on air conditioning coils

Whole-House Air Cleaner
Trap
 a high percentage of airborne
particles

Whole-House Humidifier
Moisturize
 parched air, maintaining
40% to 60% humidity to minimize
adverse health effects

Zoning System
Control
 temperature by area in your
home, adding convenience and
improving comfort

PerfectWindow

®

 Air Exchanger

Ventilate your home to assure fresh air
while minimizing energy loss

Programmable Thermostat
Save
 up to 30% in annual energy costs
with this easy-to-use thermostat that's
accurate to within ±1°    

Table 1. AIRWATCH Indicator LCD Description.

AIRWATCH™ Indicator

Condition

Meaning/Action

No indicator on.

AIRWATCH has no power; replace battery.

On/Battery indicator on continuously.

AIRWATCH is functioning normally.

On/Battery indicator flashing.

Flashing two seconds on, six seconds off: Replace battery in the F200E door. Do not

press any reset buttons after battery change.

Flashing two seconds on, two seconds off: Replace battery in AIRWATCH. Do not
press any reset buttons after battery change.

Flashing alternates between two seconds on, six seconds off; then two seconds on,
two seconds off: Replace the batteries in both units. Do not press any reset buttons
after battery change.

Air Cleaner indicator flashing.

Signal was received from transmitter, indicating either excessive pressure drop or 12-
month timer in F200E expired. Replace filter and press reset button on F200E door.

UV Air Treatment indicator flashing or

Humidifier indicator flashing.

UV lamp(s) or humidifier pad needs replacing. Replace parts.

On the AIRWATCH, push and release button until desired device indicator is flashing.
Then press button again and hold until Indicator comes on continuously; then release.

All indicators flashing.

System is in check-out mode. Indicators flash for two minutes, then AIRWATCH

automatically resets.

Summary of Contents for F200E

Page 1: ...reased pressure drop threshold at filter Filter change status is transmitted to wall mounted AIRWATCH Indicator The RF AIRWATCH Indicator is included SPECIFICATIONS IMPORTANT The specifications in this publication do not include normal manufacturing tolerances therefore an individual unit may not exactly match the listed specifications This product is tested and calibrated under closely controlled...

Page 2: ...ated for greater media capacity Filter Element Underwriters Laboratories Inc UL 900 Class 2 Listed Capacity And Pressure Drop See Fig 2 Initial Pressure Drop 0 177 in wc at 492 fpm Temperature Rating 40 to 140 F 40 to 60 C Dimensions See Fig 1 Fig 1 Installation dimensions in in mm of air cleaner Mounting Mounts in any position in the return air duct usually next to the furnace blower compartment ...

Page 3: ...ton on the F200E door to reset both the door indicator light and the RF AIRWATCH Air Cleaner Indicator See Table 1 for AIRWATCH operation Fig 2 Capacity Pressure Drop and Area of F100F Filter Media PLANNING THE INSTALLATION Location The media air cleaner should be installed where all the air passing through the system is circulated through it The best location is in the return air duct next to the...

Page 4: ...ing in closet door Fig 6 Lowboy furnace with media air cleaner mounted horizontally in return plenum just above furnace and opposite heating plenum Fig 7 Counterflow furnace with media air cleaner mounted horizontally in return duct or plenum just above furnace M941A Fig 8 Central fan installation with media air cleaner mounted horizontally in central return duct M14788 M14789 M14790 ...

Page 5: ... of expansion on each side of a transition fitting Turning Vanes If the media air cleaner is installed next to an elbow or angle fitting add turning vanes inside the angle to distribute airflow more evenly across the face of the media See Fig 12 Offsets If the duct connection to the furnace in a side installation allows less than 7 in 178 mm for mounting media air cleaner cabinet attach an offset ...

Page 6: ...ll them whenever an abrupt 90 degree elbow is installed directly against the media air cleaner cabinet Fasten Cabinet To Ductwork Fasten side of cabinet to the ductwork using sheet metal screws rivets or slip joints as appropriate Connect Ductwork Connect the vertical duct section to the elbow If the vertical drop of the duct is less than 7 in 178 mm from the side of the furnace shorten the horizo...

Page 7: ... again at step 2 Mount AIRWATCH Indicator 1 Remove the AIRWATCH Indicator from the base a Depress the tab on the bottom edge of the base b Pull off the bottom of the front cover 2 Position the base on the wall in the desired mounting position using the holes in the base as a template mark the locations for the anchors and screws provided Also mark location of round hole in center of base when usin...

Page 8: ...e 1 AIRWATCH Indicator LCD Description AIRWATCH Indicator Condition Meaning Action No indicator on AIRWATCH has no power replace battery On Battery indicator on continuously AIRWATCH is functioning normally On Battery indicator flashing Flashing two seconds on six seconds off Replace battery in the F200E door Do not press any reset buttons after battery change Flashing two seconds on two seconds o...

Reviews: