Honeywell F118 Product Data Download Page 12

68-0209-2 Revised 11-07

www.cleanairfacility.com 

Air-Pure Systems.

16873 Fish Point Rd. SE
Prior Lake, MN  55372-1714
Phone: (800) 998-1919
Fax: (800) 221-3248

F118 IN-CEILING MEDIA AIR CLEANER

LIMITED TWO-YEAR WARRANTY

Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use and service, for a period 
of two (2) years from the date of purchase by the original end-user. If at anytime during the warranty period the product is defective or malfunc-
tions, Air-Pure Systems, through the distributor or dealer, from which the product was purchased, or through an authorized warranty repair 
station, shall at Air-Pure Systems option, replace or repair the defective product or component.

This warranty does not cover removal or installation costs. This warranty shall not apply if it is shown that the defect or malfunction was caused 
by damage which occurred during handling or shipment, improper electrical connections, improper use of the product or abuse.

Air-Pure Systems sole responsibility shall be to repair or replace the product within the terms stated above. 

AIR-PURE SYSTEMS SHALL NOT 

BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, 
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD-
UCT. 

(Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.) 

THE 

WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND AIR-PURE SYTEMS EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, 
WHETHER WRITTEN OR ORAL, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABIL-
ITY, WORKMANSHIP, OR FITNESS FOR A PARTICULAR USE.

This warranty gives you specific legal rights and you may have other rights which vary from state to state.

How to make a warranty claim or have questions answered:

Should you have a warranty claim or questions about the warranty policy, contact the distributor or dealer from which you purchased the product 
or the authorized warranty repair stations nearest your location.

NOTE:

Do not return any products or parts to the factory without a factory issued “Returned Warranty Goods Label” issued by Air-Pure Sys-
tems.

In the event you or other persons, have any questions concerning the use and care of this product or this warranty please call or write the factory.

Air-Pure Systems

16873 Fish Point Rd. SE
Prior Lake, MN  55372-1714
Phone: (800) 998-1919
Fax: (800) 221-3248

Summary of Contents for F118

Page 1: ...throughout the space This effect is the tendency of air to travel close to a wall contour when ejected from a jet The air cleaner draws contaminated air up from the center of the room forces it through the filters and then blows the filtered air out through the narrow ends of the air cleaner FEATURES The DOP particle filter is 95 percent efficient at 0 3 micron particles and more efficient on part...

Page 2: ... C to 66 C Operating Ambient temperatures usually below 77 F 25 C but occasionally as high as 104 F 40 C Humidity Up to 95 relative humidity non condensing Air Volume Electrical Ratings Grille Type Perforated metal Dimensions Fig 1 Approximate dimensions of F118 in in mm Mounting Hangs freely from structural ceiling Can be recessed into a drop ceiling frame Weight Shipping Cabinet and Contents 119...

Page 3: ...hang from a structural ceiling It mounts horizontally inside or outside of a drop ceiling system It also fits between joists set 24 in 610 mm on center When used with a drop ceiling system allow at least 12 in 305 mm clearance between the structural and drop ceiling to allow space for the air cleaner To ensure unobstructed airflow the grille which is one inch 25 mm deep must protrude below the dro...

Page 4: ...he spring loaded plungers at the other end of the cabinet c Set aside the grille 2 Remove the filters a Pre filter is wrapped around the particulate filter Two support rods in the center bay of the cabinet hold the particulate filter and the pre filter in place Push these rods apart and lift the filters out of the cabinet b Two CPZ sorbent modules wrapped in plastic are located at either end of th...

Page 5: ...wire a minimum of four times WARNING Equipment Falling Hazard Can cause personal injury structural weakening buckling or damage to equipment Be sure platform is stable and can support combined weight of installer and equipment Use assistant to help support equipment during instal lation DROP CEILING F118 BE SURE TO TWIST THE SUPPORT WIRE A MIINIMUM OF FOUR TIMES TO PROPERLY BEAR WEIGHT THERE MUST ...

Page 6: ... power and check for proper opera tion for two to three minutes There should be a smooth powerful blower sound with air discharging from both ends of the air cleaner 3 Turn off the power Install Filters CAUTION Eye Exposure Harmful dust can obstruct or injure unshielded eyes CPZ module normally releases dust when handled Always wear safety glasses when installing or remov ing CPZ module CAUTION Fi...

Page 7: ...pring loaded plungers and hardware at the opposite end of the cabinet 4 Close and latch the grille When installed and latched the grille protrudes about one inch below the surface of the drop ceiling Proper operation of the air cleaner requires that it be level Fig 8 Installing grille F118 CABINET TIP CPZ SORBENT FILTER MODULE SLIGHTLY TO INSERT INTO F118 CABINET M14418 SET CORNER OF FILTER MODULE...

Page 8: ... In a heavily contaminated area up to 15 air exchanges per hour can be necessary The factors that determine the rate of air exchange are Generation rates of the various pollutants Concentration level of the pollutants Desired contamination reduction level SERVICE WARNING Fire or Electric Shock Hazard Can cause personal injury or equipment damage Turn off power source before servicing air cleaner I...

Page 9: ...nt media life ranges from 12 to 18 months Change modules and filters more frequently in facilities that operate 24 hours a day NOTE When tobacco smoke is a contaminant both the par ticle filter and the CPZ adsorbent filter must be ser viced at the same time CAUTION Eye Exposure Harmful dust can obstruct or injure unshielded eyes CPZ modules normally release dust when handled Always wear safety gla...

Page 10: ...F118 IN CEILING MEDIA AIR CLEANER 68 0209 2 Revised 11 07 10 Fig 10 F118 Air Cleaner components 1 3 2 4 M14421 5 8 9 7 6 ...

Page 11: ...F118 IN CEILING MEDIA AIR CLEANER 11 68 0209 2 Revised 11 07 NOTES ...

Page 12: ...NY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PROD UCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND AIR PURE SYTEMS EXPR...