20
Installation and Setup
2.
Pre-drill the holes as indicated on the template, using the recommended hole size for
the screws being used.
Note
Other fasteners (preferably stainless steel) can be used, provided they are not
larger than the screw holes on the mounting template.
Connecting the Wires
Caution
Installation must be performed by a qualified electrician. The power
wire size for the distance and the number of cameras must be
determined to maintain 24 V AC at each camera.
Connecting Audio and Alarms
1.
Pull the wires through the ceiling or wall hole until you have at least 4 inches of wire.
2.
Remove the green connector strip (see
) from the camera base
and make all the necessary alarm and audio connections.
3.
Connect a twisted pair (UTP) cable from each peripheral alarm contact to each alarm
input on the terminal block, as shown in
Figure 2-3
Audio and Alarm PINs
1
2
3
4
5
6
7
8
Power
Table 2-1
Audio and Alarm Connector PIN Definitions
PIN
Definition
1
Audio In +
2
Audio In -
3
Audio Out +
4
Audio Out -
5
Alarm In +
6
Alarm In -
7
Alarm Out +
8
Alarm Out -