background image

Congratulations...

Quality / Reliability...

You now own a powerful and highly efficient portable air cleaner.

Our customer service center representatives will be pleased to help with any
questions or concerns you may have about your Honeywell air cleaner.
Please call our Consumer Relations Dept. at (800) 332-1110 for assistance.

Your air cleaner is quality engineered for simplicity and reliability and is manufactured
with durable, high impact plastic housings which are scratch, stain, and corrosion
resistant. With reasonable care and replacement of filters as recommended, it will
give you years of trouble free performance.

Your 

Honeywell

air cleaner has six

basic components: lid assembly and
handle, the CPZ™ odor and gas
adsorbing filter, the HEPA filter, the
activated carbon pre-filter, the protecive
screen and the base assembly (with
controls and motor).

Construction ...

Lid Assembly
and Handle

CPZ

TM

Sorbent

Media Cartridge

Protective Screen

Activated 
Carbon Pre-filter

HEPA 
Filter Cartridge

Base Assembly 

;;;;;

;;;;;

;;;;;

0

1

2

0

1

2

HEPA / CPZ

TM

enviracaire

®

41000 Series ...

The 

Honeywell

41000 Series air cleaner is a 2

speed air cleaner operated by moving the speed
control from the off (“0”) position to the High (“2”)
position. Allow the unit to operate for a few seconds
at high speed, then leave the control knob in the
high position for faster, powerful room cleaning, or
move the knob to the lower setting for quieter
operation.

Before Operating Your Air Cleaner...

• Read this manual and follow all safety instructions.

• Carefully remove the plastic bag which protects the CPZ™ Filter cartridge during
shipment. Your air cleaner will not operate properly with the plastic bag in place, and
it may damage the air cleaner. The plastic bag may contain small particles and dust
caused by vibration of the CPZ™ cartridge during shipment. Use care to avoid soiling
clothing, carpets, and other furnishings with the particles or dust.

See the “How to

Change the Filters...” section of this owners manual for filter removal instructions.

Summary of Contents for enviracaire 41000 Series

Page 1: ... INSTRUCTIONS Owner s Guide For Air Cleaner Models 41000 42000 43000 and 44000 Series The Science of Clean Air 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 0 1 2 HEPA CPZ TM enviracaire ...

Page 2: ...laundry area or other damp location 10 To disconnect the air cleaner first turn speed control to OFF position and remove plug from the outlet 11 The air cleaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Locate air cleaner near power...

Page 3: ... Sorbent Media Cartridge Protective Screen Activated Carbon Pre filter HEPA Filter Cartridge Base Assembly 0 1 2 0 1 2 HEPA CPZ TM enviracaire 41000 Series The Honeywell 41000 Series air cleaner is a 2 speed air cleaner operated by moving the speed control from the off 0 position to the High 2 position Allow the unit to operate for a few seconds at high speed then leave the control knob in the hig...

Page 4: ...eaners operated by moving the speed control knob on the base from the Off 0 position to the high 3 position Allow the unit to operate for a few seconds at high speed then leave the control knob in the high position for faster powerful room cleaning or move the knob to a lower setting for quieter operation 0 1 2 3 HEPA CPZ TM enviracaire Replacement Filters Select the proper replacement filter for ...

Page 5: ...lines every 3 years for light usage 2 years for normal usage and 1 year for heavy usage The CPZ Filter Cartridge should be replaced at least every 6 months Filter life depends upon condition of use Our recommendations regarding filter replacement intervals are intended as guidelines only Life expectancy of any filter media is dependent on the concentration of the contaminants to which the system i...

Page 6: ...r Honeywell air cleaner as described below 1 Place the assembled HEPA filter CPZ filter and the activated carbon pre filter on the base 2 Replace the protective screen and lid 3 Reattach the carrying handle and turn it clockwise until securely tightened CAUTION DISCONNECT FROM POWER SUPPLY BEFORE SERVICING Check to make sure that the power cord is correctly connected to the outlet Test the outlet ...

Page 7: ... the unit Discard the pre filter and CPZ filter Wrap the HEPA filter in an air tight plastic bag or plastic wrap Be sure that the filter is totally sealed To restore the air cleaner to service unwrap the HEPA filter install a new activated carbon pre filter and CPZ filter reasemble in the air cleaner See How to Change the Filters section for proper installation Storage ...

Page 8: ... Honeywell will repair or replace this product if it is found to be defective in material or workmanship Defective product should be returned to the place of purchase in accordance with store policy or to Honeywell C This warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual D This warranty DOES NOT cover the pre filter CPZ...