background image

Please read all instructions before using this product. Save these instructions for
easy reference.

When using electrical appliances, basic precautions should always be followed to
reduce breakage, risk of fire, electric shock and injury to persons including the following:

1. Read all instructions before operating the air cleaner.

2. Place air cleaner where it is not easily knocked over by persons in the

household.

3. Always unplug when not in use. It is recommended that the air cleaner be

attended while in use.

4. Do not use any product with a damaged cord or plug or if product malfunctions, is

dropped or damaged in any manner. Keep the cord away from heated surfaces.

5. Do not use air cleaner outdoors.

6. Never use air cleaner unless it is fully assembled.

7.

Warning:

To reduce the risk of fire or overheating of the electrical cord, do not

run power cord under carpets, and do not cover with throw rugs. Arrange cord
such that it will not be tripped over.

8. Do not use air cleaner where combustible gases or vapors are present.

9. Do not expose the air cleaner or CPZ™ Filter to rain, or use near water, in a

bathroom, laundry area or other damp location.

10. To disconnect the air cleaner, first turn speed control to OFF position and remove

plug from the outlet.

11. The air cleaner must be used in its upright position.

12. Do not allow foreign objects to enter ventilation or exhaust opening as this 

may cause electric shock or damage to the air cleaner. Do not block air outlets 
or intakes.

13. Locate air cleaner near power outlet and avoid using an extension cord.

14. The air cleaner has a polarized plug (one blade is wider than the other). To

reduce risk of shock, this plug is intended to fit in a polarized outlet only one way.
If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician.

DO NOT

attempt to defeat this safety feature.

15.

Caution:

a loose fit between the plug and the AC outlet (receptacle) may cause 

overheating and a distortion of the plug. Contact a qualified electrician to 
replace loose or worn receptacles.

16. Do not sit, stand or place heavy objects on the air cleaner.

17. Disconnect power supply before servicing.

18.

Warning:

To reduce the risk of fire or electric shock, do not use this product with

any solid-state speed control device.

19. Do not wash the filters. The filters are not washable and doing so will cause

damage.

Important Safety Instructions ...

Summary of Contents for enviracaire 41000 Series

Page 1: ... INSTRUCTIONS Owner s Guide For Air Cleaner Models 41000 42000 43000 and 44000 Series The Science of Clean Air 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 3 HEPA CPZ TM enviracaire 0 1 2 0 1 2 HEPA CPZ TM enviracaire ...

Page 2: ...laundry area or other damp location 10 To disconnect the air cleaner first turn speed control to OFF position and remove plug from the outlet 11 The air cleaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Locate air cleaner near power...

Page 3: ... Sorbent Media Cartridge Protective Screen Activated Carbon Pre filter HEPA Filter Cartridge Base Assembly 0 1 2 0 1 2 HEPA CPZ TM enviracaire 41000 Series The Honeywell 41000 Series air cleaner is a 2 speed air cleaner operated by moving the speed control from the off 0 position to the High 2 position Allow the unit to operate for a few seconds at high speed then leave the control knob in the hig...

Page 4: ...eaners operated by moving the speed control knob on the base from the Off 0 position to the high 3 position Allow the unit to operate for a few seconds at high speed then leave the control knob in the high position for faster powerful room cleaning or move the knob to a lower setting for quieter operation 0 1 2 3 HEPA CPZ TM enviracaire Replacement Filters Select the proper replacement filter for ...

Page 5: ...lines every 3 years for light usage 2 years for normal usage and 1 year for heavy usage The CPZ Filter Cartridge should be replaced at least every 6 months Filter life depends upon condition of use Our recommendations regarding filter replacement intervals are intended as guidelines only Life expectancy of any filter media is dependent on the concentration of the contaminants to which the system i...

Page 6: ...r Honeywell air cleaner as described below 1 Place the assembled HEPA filter CPZ filter and the activated carbon pre filter on the base 2 Replace the protective screen and lid 3 Reattach the carrying handle and turn it clockwise until securely tightened CAUTION DISCONNECT FROM POWER SUPPLY BEFORE SERVICING Check to make sure that the power cord is correctly connected to the outlet Test the outlet ...

Page 7: ... the unit Discard the pre filter and CPZ filter Wrap the HEPA filter in an air tight plastic bag or plastic wrap Be sure that the filter is totally sealed To restore the air cleaner to service unwrap the HEPA filter install a new activated carbon pre filter and CPZ filter reasemble in the air cleaner See How to Change the Filters section for proper installation Storage ...

Page 8: ... Honeywell will repair or replace this product if it is found to be defective in material or workmanship Defective product should be returned to the place of purchase in accordance with store policy or to Honeywell C This warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual D This warranty DOES NOT cover the pre filter CPZ...

Reviews: