PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. Save these
instructions for easy reference.

When using electrical appliances, basic precautions should always be followed to reduce
breakage, risk of fire, electric shock and injury to persons including the following:

1. Read all instructions before operating the air cleaner.

2. Place air cleaner where it is not easily knocked over by persons in the household.

3. Always unplug when not in use.

4. Do not use any product with a damaged cord or plug or if product malfunctions, is

dropped or damaged in any manner. Keep the cord away from heated surfaces.

5. Do not use air cleaner outdoors.

6. Never use air cleaner unless it is fully assembled.

7. Do not run power cord under carpets, and do not cover with throw rugs. Arrange

cord such that it will not be tripped over.

8. Do not use air cleaner where combustible gases or vapors are present.

9. Do not expose the air cleaner to rain, or use near water, in a bathroom, laundry

area or other damp location.

10. To disconnect the air cleaner, first turn speed control to OFF position and remove

plug from the outlet.

11. The air cleaner must be used in its upright position.

12. Do not allow foreign objects to enter ventilation or exhaust opening as this may

cause electric shock or damage to the air cleaner. Do not block air outlets or
intakes.

13. Locate air cleaner near power outlet and avoid using an extension cord.

14. The air cleaner has a polarized plug (one blade is wider than the other). To reduce

risk of shock, this plug is intended to fit in a polarized outlet only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician.

DO NOT

attempt to defeat this safety feature.

15. A loose fit between the plug and the AC outlet (receptacle) may cause overheating

and a distortion of the plug. Contact a qualified electrician to replace loose or worn
receptacles.

16. Do not sit, stand or place heavy objects on the air cleaner.

17. Disconnect power supply before servicing.

18. WARNING: To reduce risk of fire or electric shock, do not use this product

with any solid-state speed control device.

Important Safety Instructions ...

Summary of Contents for enviracaire 10500 Series

Page 1: ...ner s Guide For Model Series 10500 11500 12500 13350 13500 and 14500 Air Cleaners The Science of Clean Air 0 1 2 3 HEPA CPZ 0 1 2 3 HEPAFiltration True 0 1 2 3 HEPAFiltration True 0 1 2 3 250i 0 1 2 3 HEPAFiltration True 0 1 2 HEPAFiltration True 0 1 2 0 1 2 150i ...

Page 2: ... location 10 To disconnect the air cleaner first turn speed control to OFF position and remove plug from the outlet 11 The air cleaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Locate air cleaner near power outlet and avoid using an...

Page 3: ...ce We recommend that you operate your Honeywell air cleaner 24 hours a day because indoor air can be quickly contaminated by activity in a room infiltration of outside air and generation by sources of contamination While all the air in a room will not be processed by the air cleaner the more air circulated through the filter the more filtered air returned to the room Portable air cleaners will be ...

Page 4: ...e from the Off 0 position to the high 3 position Allow the unit to operate for a few seconds at high speed then leave the control knob in the high position for faster powerful room cleaning or move the knob to a lower setting for quieter operation 0 1 2 3 HEPAFiltration True 0 1 2 HEPAFiltration True The Honeywell 13350 13500 and 14500 Series air cleaner is a 3 speed air cleaner operated by moving...

Page 5: ...8002 11500 Series 21500 32002 38002 12500 Series 22500 33002 38002 13350 and 13500 Series 24000 34002 38002 14500 Series 25000 38002 Model No HEPA Filter Part Number Carbon Pre filter Part Number Base Assembly Activated Carbon Pre filter HEPA Filter Filter Cage Cover Replacement filters may be purchased from the retail store or ordered from the dealer where you purchased the product If you cannot ...

Page 6: ... of the filter media in your air cleaner may be reduced Whenever the combined air resistance of the activated carbon pre filter and primary HEPA filter becomes excessive due to the amount of contaminants they have captured the air cleaner will begin to audibly pulsate Instead of a steady stream of air rapid puffs of air may be felt at the outlet slot When this occurs one of two conditions exists 1...

Page 7: ...clockwise until it snaps securely into place Place the power control switch in the OFF position If you store your Honeywell HEPA air cleaner for more than 30 days we recommend Remove both the primary HEPA filter and the activated carbon pre filter from the unit Discard the pre filter Wrap the HEPA filter in an air tight plastic bag or plastic wrap Be sure that the filter is totally sealed To resto...

Page 8: ...ll will repair or replace this product if it is found to be defective in material or workmanship within the warranty period Defective product should be returned to the place of purchase in accordance with store policy or to Honeywell C This warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual D This warranty DOES NOT cover...