Honeywell DV100L Installation Instructions Manual Download Page 15

Version:A

Revision Data: 12/14/2005

Description:

Electronic ballast for compact fluorescent Lamp (1) Quad 4pin 26W or (1) TwinT5 4pin 24W or (1)T5 linear 24W

• Line Voltage :  120Vac, 60Hz

• Rapid Start

• Lamp Connection: Single Lamp WS-1 

Input Power

Crest

Volts

Freq-Hz

Watts*

Factor

Factor

27

25

24

*ANSI measured wattage,25

ć

 ambient,benchtop,lamps base up ; Enclosed fixture, wattage may change depending on fixture type.

**Lamp Type: Quad 4pin T4

Application and Performance Specification Information Subject to Change without Notification.

Performance:

Safety:

•  Meets ANSI Standard C82.11-1993

•  No PCB's

•  Meets ANSI Standard C62.41-1991

•  UL listed 

(Class P)

•  Meets UL 935  

•  UL # 221323

•  Meets FCC Part 18 (Class B) for EMI
•  Operating Frequency Range: 45-55 kHz

•  Abnormal Protection Circuit 

•  End of lamp  life protection Circuit 

•  Auto-Reset Shutdown Circuit 

- lamp(s) should be replaced at end of lamp life
- Lamp relights upon insertion in socket

Application:

Physical Parameters

•  Minimum Starting Temperature: 

5° F   (-15° C)

Case: 

CM-31(#90-5B)

•  Maximum Ambient Temperature:

122° F(50° C)

Overall Length(L): 3.86"(99mm)

•  Maximum Case Temperature (@ t

c

):

158° F(70° C)

Width(W):

2"(52mm)

•  Sound Rated:

A

Mounting(M):

3.5"(90mm)

Height(H):

1.00"(25.4mm)

Weight:

0.55bs(0.25kg)

Qty/Carton:

30

Color:

Black/White

Can Material:

Metal
Black

320mm

Wire length:

White

300mm

 (±25.4mm)

Blue  

240mm*2

Red   

240mm*2

Install in accordance with
the National Electrical Code

Ballast must be grounded.

FCC NOTE:

The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modification

could void the user's authority to operate the equipment.

This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other

critical navigation or communication equipment operating between 0.450-30MHz.

Warranty:

Universal Lighting China warrants to the purchaser that each electronic ballast will be free from defects in material or
workmanship for a period of  3 years from date of manufacture when properly installed and under normal conditions of use. 

Call

8621-64808118*218,128

 for technical assistance.

ƻƻƻƻƿƿ

Manufactured in China

#90-5B

120

60

CBT-126L-120S

1

0.56

<1.7

0.32

CBT-126L-120S

APPLICATION and PERFORMANCE SPECIFICATION

Line

Case ULC #

No.of

lamps

Model

Nominal

Line Amps

Lamp

Type**

T5 linear 24W

26W/8T4/Q/G24q-3

(Quad 4pin/PL-C 26W)

24-27W/13T5/T/2G11/PH-RS

(Twin T5 4pin/PL-L 24W)

0.39

0.37

BALLAST

Red

Blue

White

Black

Summary of Contents for DV100L

Page 1: ...ternational Inc Makes no representations or warranties with respect to this product Page1 Honeywell Decorative Ventilation Fan Light Nightlight CLEANING MAINTENANCE 10 SERVICE PARTS 11 ACCESSORIES 2 DESCRIPTION 3 DIMENSION 3 SPECIFICATIONS 4 GENERAL SAFETY INFORMATION 4 INSTALLATION 6 WARRANTY 13 Table of Contents Ventilation Fan Light Nightlight Model V50L V70L V80L V90L V100L V110L Model ModelDV...

Page 2: ... Screw C M4X30 4 4 1 Glass panel unit Decorative cap Nut Bolt ACCESSORIES DV50L DV70L DV80L DV90L DV100L DV110L 4W Incandescent Lamp 1 Part name Picture Part name Picture Quantity Quantity Grille Screw B M4X30 1 1 Screw A M4X10 Light unit 26W Fluorescent Lamp 2 4 1 A ACCESSORIES V50L V70L V80L 90L V100L V110L 4W Incandescent Lamp 1 Page2 ...

Page 3: ...use What s more Honeywell fans can help clear the air quickly and help remove irritants before they cause problems in your home Honeywell ceiling mounted ventilation fans use high capacity sirocco fan driven by capacitor motor The sirocco fan reduce the noise level The motor is designed to have an extended service life with reduced energy consumption Honeywell ventilation fans also incorporate a t...

Page 4: ...0 2 Make sure that the electric service supply voltage is 120V 60Hz 3 Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA 4 Always disconnect the power source before working on or near the fan motor or junction box or light fixture 5 Protect the power cord from sharp edges oil grease hot surfaces chemicals or other ...

Page 5: ...ient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Page 6: ...equirements 6 Not for use in cooking area Fig 2 Cooking area Do not install above or Inside this area Floor Cooking Equipment 45 45 Power cable Ceiling joist Grille Ceiling material Suspension bracket Housing Housing mounted directly to joist 2x4 or larger Discharge parallel to joist Suspension bracket Power cable Additional framing 4 Round duct Ceiling material Ceiling joist Grille Housing Housin...

Page 7: ...STALLATIONS The unit operates most quietly and efficientlywhen located where the shortest possible duct run and minimum number of elbows are needed Fig 3 Plan to supply the unit with proper line voltage and appropriate power cable NOTE THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2X6 JOISTS IF YOU HAVE A TRUSS OR I JOIST INSTALLATION MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MANN...

Page 8: ...Set housing aside and drive nails partially into joist at the top of both keyhole marks Fig 5 4 Hang housing from nails and pound nails tight To ensure a noise free mount pound another nail through the top hole of mounting bracket A Fig 6 INSTALLATION joist mounting Fig 11 Fig 12 STEP 3 INSTALL THE DUCTWORK 1 Attach damper duct connector Snap the damper duct connector onto housing Make sure that t...

Page 9: ...he fluorescent lamp and screw the night lamp into the lighting unit 5 Squeeze grill springs and insert them into slot on each side of scroll Push grill against ceiling Fig 15 Fig 16 Screw Spring 1 Install ceiling material Cut out around housing 2 Mounting the motor unit into the housing and fastness with one M4x16 screw Fig 17 3 Screw the bolt into motor plate Fig 18 4 Insert the plug connector in...

Page 10: ...he 4W incandescent lamp connect the connectors and replace grille pan unit glass panel and decorative caps Page10 Fig 17 Fig 18 Housing Motor unit Screw Lighting unit Bolt Connector Fig 19 Grille pan Nut Fig 20 Glass panel Fig 21 Screw WARNING 1 Disconnect power source before working on unit Routine maintenance must be done every year 2 The lamp s glass is fragile Please handle with care To remove...

Page 11: ... cover Lamp holder Blower Wheel setting nut Blower Wheel Spring hook Condenser box cover Condenser Casing These instructions may be printed in English the English version and one or more other languages other versions in which case the English version shall prevail if there is any inconsistency between the English version and any one or more of the other versions Grille spring Grille 3 4 5 6 7 8 1...

Page 12: ... bracket Female pin connector Compact Fluorescent Lamp Wiring cover Lamp holder Blower Wheel setting nut Bolt Blower Wheel Grille pan Condenser box cover Nut Condenser Glass panel unit Casing Decorative cap These instructions may be printed in English the English version and one or more other languages other versions in which case the English version shall prevail if there is any inconsistency bet...

Page 13: ...e Warranty Period at its option replace or repair free of charge the Product or part thereof which LONON determines is defective under normal use and maintenance This Warranty does not cover and LONON is not responsible for i normal maintenance and service ii any Product which has been subjected to misuse improper maintenance or modification neglect electrical current fluctuations negligence accid...

Page 14: ...rized to give any other warranties or assume any other liability on LONON s behalf in connection with the Product except in writing signed by an authorized officer of LONON Notwithstanding any past practice or dealings or any custom of the trade the supply of the Product does not include the provision of any technical advice or system design which may be provided at LONON s sole option and subject...

Page 15: ...ed A Mounting M 3 5 90mm Height H 1 00 25 4mm Weight 0 55bs 0 25kg Qty Carton 30 Color Black White Can Material Metal Black 320mm Wire length White 300mm 25 4mm Blue 240mm 2 Red 240mm 2 Install in accordance with the National Electrical Code Ballast must be grounded FCC NOTE The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment ...