Honeywell DELUXEHEATPUMP T8511G Installation Instructions Manual Download Page 5

69-1052—1

5

T8511G DELUXE HEAT PUMP ZONE THERMOSTAT

Table 2. Thermostat Installer Setup Options.

a

Available on select models.

Installer Setup

Number

(Press   

  key

Factory Setting

Other Choices  

(Press 

 or  

 key to change)

Actual

Select

to change)

Display

Description

Display

Description

Setting

Not used

01 thru 04

Heating cycle  

05

06

Stage 2

03, 06

03—3 cph used for hot water

rate

06

Not used

or 09

systems

07

06

Emergency heat

06—6 cph used for heat pump

systems  

09—9 cph used for electric heat

systems

Not used

08 thru 11

Changeover  

12  

01

Manual changeover

00 or

02

00—Automatic changeover
02—Auto only

Not used

13  

Degree tempera-
ture display

14

00

Temperature is
displayed in °F

01

Temperature is displayed  
in °C

Not used

15 thru 18  

Extended fan
operation in
heating

19  

00

No extended fan
operation after the
call for heat ends

01

Fan operation is extended  
90 seconds after the call for  
heat ends

Extended fan
operation in
cooling

20  

00

No extended fan
operation after the
call for cool ends

01

Fan operation is extended  
90 seconds after the call for  
cool ends

Not used

21 thru 23  

Outdoor
temperature
display

a

24

00

No outdoor
temperature is
displayed

01

Outdoor temperature is
displayed. Needs a C7089B1000
Outdoor Sensor to operate.

Not used

25 thru 32

Minimum off time
for the
compressor

33

05

5 minute minimum off
time for the
compressor

00, 01,
02, 03
or 04

Minimum number of minutes  
(0 thru 5) the compressor will be
off between calls for the
compressor

Heating setpoint
range stop

a

34

90

Heating setpoint can
be set no higher than
90°F

40 thru
90

Number can be set anywhere
between 40 and 90 in 1°F
increments

Cooling setpoint
range stop

a

35

48

Cooling setpoint can
be set no lower than
48°F

48 thru
99

Number can be set anywhere
between 48 and 99 in 1°F
increments

System on
indicator
(flame=heat,
snowflake=cool)
is displayed

a

36

00

LCD On symbol is
displayed when
system is energized

01

Display is disabled

Temperature
display
adjustment

37

00

No difference in
displayed
temperature and
actual room
temperature

-3 thru
03

01—Display adjusts to 1°F higher
than actual room temperature
02—Display adjusts to 2°F higher
than actual room temperature
03—Display adjusts to 3°F higher
than actual room temperature
-1—Display adjusts to 1°F lower
than actual room temperature
-2—Display adjusts to 2°F lower
than actual room temperature
-3—Display adjusts to 3°F lower
than actual room temperature

Summary of Contents for DELUXEHEATPUMP T8511G

Page 1: ...application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation Location Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average temperature See Fig 1 Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in corn...

Page 2: ...nect power before wiring to prevent electrical shock or equipment damage 1 Loosen the terminal screws on the wallplate and connect the system wires See Fig 5 IMPORTANT Use 18 gauge color coded thermostat cable for proper wiring 2 Securely tighten each terminal screw 3 Push excess wire back into the hole 4 Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat 5 ...

Page 3: ...erature select models set the system operation set the fan operation See Fig 7 for the location of the keys Fig 7 Key locations and descriptions O G B L C R Y E W2 OT OT O1 T8 G1 T7 B1 T6 E1 T5 T4 M1 THERMOSTAT CHANGEOVER CONTROL OUTDOOR TEMPERATURE SENSOR ZONE 1 M12188 B E L G Y R O W2 C OT W2 L G Y R W M6 M4 M1 OT THERMOSTAT TotalZone PANEL THERMOSTAT CONNECTIONS OUTDOOR TEMPERATURE SENSOR OPTIO...

Page 4: ...figuration options and the factory settings for the T8511G A combination of key presses are required to use the Installer Setup feature To enter the Installer Setup press and hold the Information i key with the increase and decrease keys until the first number is displayed All display segments appear for approximately three seconds before the number is displayed See Fig 9 and 10 To advance to the ...

Page 5: ...ure displaya 24 00 No outdoor temperature is displayed 01 Outdoor temperature is displayed Needs a C7089B1000 Outdoor Sensor to operate Not used 25 thru 32 Minimum off time for the compressor 33 05 5 minute minimum off time for the compressor 00 01 02 03 or 04 Minimum number of minutes 0 thru 5 the compressor will be off between calls for the compressor Heating setpoint range stopa 34 90 Heating s...

Page 6: ... after ten minutes without any key presses Table 4 Installer System Test Options Continued Em HeatOffCool Auto Only Heat Cool OnAuto System Fan Room Outdoor Em Ht Temporary Setting Wait Humid Aux Ht Remote Repl Batt M4844 M6792 TEST MODE NUMBER Test Number System Test Description 10 19 Heating equipment can be turned on and off 20 29 Emergency heat select models equipment can be turned on and off ...

Page 7: ... software revision number Example 001 Revision number 1 M4864 M10444 M4866 M6791 Key to Press Test Number Description Fan Equipment System Test i 40 Change from cooling to fan equipment system test 41 Fan comes on 40 Fan turns off Key Operation System Test IMPORTANT Test numbers will only be displayed when the system is configured for the selected function EXAMPLE Numbers 60 61 and 62 are the only...

Page 8: ... if the circuit breaker is tripped reset the circuit breaker check if the system fuse is blown replace the fuse check if the power switch on the HVAC equipment is in the Off position set to the On position check wiring between thermostat and HVAC equipment replace any broken wires and tighten any loose connections If 24 Vac is present proceed with troubleshooting Thermostat microprocessor is locke...

Page 9: ...f the system fuse is blown replace the fuse check if the system switch at the equipment is in the Off position set to the On position check wiring between thermostat and HVAC equipment replace any broken wires and tighten any loose connections If 24 Vac is present proceed with troubleshooting Thermostat minimum off time is activated Wait up to five minutes for the system to respond Enter Installer...

Page 10: ...69 1052 1 10 T8511G DELUXE HEAT PUMP ZONE THERMOSTAT ...

Page 11: ...69 1052 1 11 T8511G DELUXE HEAT PUMP ZONE THERMOSTAT ...

Page 12: ... PUMP ZONE THERMOSTAT 69 1052 1 J H Rev 6 97 Printed in Taiwan R O C www honeywell com yourhome Helping You Control Your World Honeywell Trol A Temp 57 Bushes Lane Elmwood Park NJ 07407 3204 201 794 8004 800 828 8367 Fax 201 794 1359 ...