background image

12

69-1400–1

Clearing Program Period

NOTE:

The thermostat must be in the program mode to use
the clear feature. Go to step 

 if the thermostat is

already in the program mode.

Press Wake, Leave, Return or Sleep.

Press Day until the desired day is displayed.

Press Leave, Return or Sleep until the start time and
temperature setting are cleared (approximately 3 seconds).

NOTE:

Wake cannot be cleared.

Repeat steps 

 and 

 for all the periods to be cleared.

Press Run Program.

M14647

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Set Program

Mon

Leave

System

Fan

Heat

On

AM

Heat

Setting

M14648

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Day

Heat/Cool

Settings

Daylight

Time

Copy

Set Program

Leave

System

Fan

Heat

On

AM

Heat

Sat

Setting

M14649

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Leave

Set Program

Leave

Heat

Sat

Setting

Summary of Contents for Deluxe

Page 1: ...1 69 1400 1 Deluxe Programmable Thermostat 69 1400 1 ...

Page 2: ...is pressed Press Information i key for present setting information and outdoor temperature select models Select fan operation for each period of each day select models with fan key Temporarily set the temperature warmer or cooler Daylight Time key for easy switching in and out of Daylight Savings Time Program end of Hold 1 to 255 days for added comfort and energy savings Copy key for easier progra...

Page 3: ...re settings The and keys provide quick temporary tempera ture changes to increase your comfort The Hold Temp key provides energy efficient operation for extended periods of time Before starting the programming procedure you can use the following charts to organize your program schedule The factory preprogrammed time temperature and fan settings are shown in brackets If you choose not to program a ...

Page 4: ...AM 62 F 16 5 C Return 6 00 PM 70 F 21 C Sleep 10 00 PM 62 F 16 5 C Wednesday Wake 6 00 AM 70 F 21 C Leave 8 00 AM 62 F 16 5 C Return 6 00 PM 70 F 21 C Sleep 10 00 PM 62 F 16 5 C Thursday Wake 6 00 AM 70 F 21 C Leave 8 00 AM 62 F 16 5 C Return 6 00 PM 70 F 21 C Sleep 10 00 PM 62 F 16 5 C Friday Wake 6 00 AM 70 F 21 C Leave 8 00 AM 62 F 16 5 C Return 6 00 PM 70 F 21 C Sleep 10 00 PM 62 F 16 5 C ...

Page 5: ... Auto 82 F 28 C Auto 78 F 25 5 C Auto 85 F 29 5 C Auto 78 F 25 5 C Auto 82 F 28 C Auto 78 F 25 5 C Auto 85 F 29 5 C Auto 78 F 25 5 C Auto 82 F 28 C Auto 78 F 25 5 C Auto 85 F 29 5 C Auto 78 F 25 5 C Auto 82 F 28 C Auto 78 F 25 5 C Auto 85 F 29 5 C Auto 78 F 25 5 C Auto 82 F 28 C Auto ...

Page 6: ...t Day and Time IMPORTANT Always press the keys with your fingertip or similar blunt tool Sharp instruments like pens and pencil points can damage the keyboard Press Set Current Day Time NOTE On initial power up or after an extended power loss 1 00 pm flashes on the display until a key is pressed M14619 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Set Current Day Time Wake...

Page 7: ...day Sat Saturday Press Time or Time until the current time is displayed NOTE Tapping the Set Current Day Time will change the time in one hour increments M14620 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Day Heat Cool Settings Daylight Time Copy Set Day Time PM Tue M14621 Time Set Program System Fan Run Program Hold Temp Set Current Day Time ...

Page 8: ...light Time Copy Set Day Time AM DST Tue M14623 Time Set Program System Fan Run Program Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Wake Room System Fan Heat Auto AM DST Tue M14635 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Set Program W...

Page 9: ...ngs to switch to other system temperature setpoint NOTE The program times are the same for both heating and cooling M14637 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Time Set Program Mon Wake System Fan Heat Auto AM Heat Setting M14638 Time Set Program System Fan Run Program Hold Temp Set Current Day Time...

Page 10: ...the copy feature Go to step if the thermostat is already in the program mode Press Wake Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy M14640 Set Program Mon Wake System Fan Heat Auto AM Cool Setting M14641 Time Set Program System Fan Run Program Run Program Hold Temp Set Current Day Time Wake Leave Return Sl...

Page 11: ...Day Time Wake Leave Return Sleep Day Day Heat Cool Settings Daylight Time Copy Set Program Mon Wake System Fan Heat Auto AM Heat Setting M14644 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Copy Mon M14645 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Day ...

Page 12: ... be cleared Press Run Program M14647 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Set Program Mon Leave System Fan Heat On AM Heat Setting M14648 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Day Heat Cool Settings Daylight Time Copy Set Program Lea...

Page 13: ... approximately 3 seconds The setting is cancelled when the next period starts or when Run Program is pressed Changing Temperature Setting Indefinitely Press Hold Temp Press increase or decrease key to change the setting if desired M14651 Time Set Program System Fan Run Program Hold Temp Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy System Fan Heat...

Page 14: ...3 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Heat Cool Settings Daylight Time Copy Cool Setting M14654 Time Set Program System Fan Run Program Hold Temp Set Current Day Time Wake Leave Return Sleep Day Heat Cool Settings Daylight Time Copy Cool Setting M14655 Time Set Program System Fan Run Program Hold Temp Hold Temp Set C...

Page 15: ...Example Cool 84 cooling equipment will operate when the room temperature is above 84 F NOTE In this example the thermostat uses the Hold setting for eighteen days and returns to the daily programs at the Return period start time The temperature settings are heating 54 F and cooling 84 F Only the heating temperature is used because the System is set for Heat The thermostat will use both the heating...

Page 16: ...f Both the heating and cooling are off Cool The thermostat controls the cooling Auto The thermostat automatically changes between heating and cooling operation depending on the indoor temperature select models Fan settings control the system fan as follows On Fan operates continuously Auto Fan operates with equipment Setting Temporary Fan Operation If your thermostat has a Fan key and this feature...

Page 17: ...essing the i key until the exired timer is displayed 2 Press the Time key to reset the timer 3 Press the Run Program key NOTE You can view the number of days remaining at anytime by pressing the i key three or four times If more than one timer is active all active timers show sequentially when pressing the i key several times M20243 Filter Days M20244 Filter Days ...

Page 18: ...t Savings Time with a key press When pressed in the fall the time will go back one hour In the spring the time will go ahead one hour and the display will show DST See Setting the Current Day and Time section for initial setting instructions NOTE Pressing Daylight Time more than once within a five minute period will scroll you through various time options Example one hour earlier or later with or ...

Page 19: ...sible once the message flashes If you insert new batteries within 20 to 30 seconds of removing the old batteries the system retains the current time and day If the display is blank the batteries are dead or installed incor rectly You must reset the time and day Refer to Set the Clock for instructions As a precaution when leaving home for longer than a month change batteries before leaving to preve...

Page 20: ...ommon household thermometers and standard thermostats sense only air temperature which might or might not reflect how hot or cold the room actually feels to a human being Your new thermostat reads both the temperature of the wall and the air and responds to temperature changes as little as one degree Fahrenheit so room temperature is more likely to feel right to you and your family The Optimum Com...

Page 21: ...ecks how closely it hit the recovery target and adjusts the next day recovery start time accordingly It typically takes four to eight days after installation for the thermostat to adjust to the local weather your lifestyle the construction of your home and your heating cooling system The thermostat calculates the Leave Return recovery separately from the Sleep Wake recovery With the thermostat you...

Page 22: ...o the savings you can expect 30 28 26 24 22 20 18 16 14 12 8 6 2 10 4 Minneapolis St Paul Montreal Ottawa Toronto Buffalo Cleveland Milwaukee Edmonton Regina Winnipeg Calgary Moncton North Bay Quebec St John s Halifax Vancouver Denver Des Moines Omaha Salt Lake City Boston Chicago Detroit Pittsburgh Indianapolis Cincinnati Kansas City St Louis Columbus New York Philadelphia Seattle Louisville Port...

Page 23: ... breaker Check if the fuse is blown replace the fuse Check if the system switch at the equipment is in the Off position set to the On position Check wiring between thermostat and HVAC equipment replace any broken wires If 24 Vac is present proceed with troubleshooting Temperature settings will not change Example cannot set the heating higher or the cooling lower Check that the temperature setpoint...

Page 24: ...o Heat Cooling will not come on Check that setpoint is below room temperature Check if the circuit breaker is tripped reset the circuit breaker Check if the fuse is blown replace the fuse Check if the system switch at the equipment is in the Off position set to On position If 24 Vac is present proceed with troubleshooting Wait five minutes for the system to respond Set system selection to Cool Sys...

Page 25: ...lity shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential dam...

Page 26: ...26 69 1400 1 ...

Page 27: ...27 69 1400 1 ...

Page 28: ...Inc All Rights Reserved U S Registered Trademark www honeywell com yourhome Honeywell Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 429 Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley MN 55422 Printed in U S A ...

Reviews: