Honeywell D05T Quick Start Manual Download Page 7

D05T COMPACT DESIGN PRESSURE REGULATING VALVES

7

62-3021—03

OPERATION

The Honeywell Braukmann D05T is a balanced, direct acting 

pressure regulating valve. The D05T provides constant 

downstream pressure regardless of varying inlet pressures and 

downstream flow demands. 

The spring force holds the valve in the open position until 

downstream pressure, sensed by a port, is sufficient to press 

on the underside of the diaphragm and close the valve. As 

downstream pressure drops due to demand, the force on the 

diaphragm is reduced and the valve opens. Adjustment is 

made by manually turning the adjustment screw clockwise      

to increase the spring force and require a higher downstream 

pressure to close the valve. Similarly, reducing the spring force 

lowers the outlet set pressure.

Once the outlet pressure is set, the D05T automatically 

regulates to maintain the downstream pressure. See Fig. 5 for 

the internal construction of the D05T.

Fig. 5. Internal construction of D05T.

TROUBLESHOOTING

Table 3 provides a troubleshooting guide for the D05T Pressure Regulating Valves.

Table 3. Troubleshooting the D05T Pressure Regulating Valves.

D05T Parts and Accessories

Order Number

Description

Replacement Parts

203223

Bonnet Assembly for 3/4 in. Valves.

203224

Bonnet Assembly for 1 in. Valves.

272841

Gasket for 3/4 in. D05T/DS05 (quantity 

24).

272842

Gasket for 1 in. D05T/DS05 (quantity 24).

K05A1009

Replacement Cartridge, Screen and O-ring 

for 3/4 in. Valves.

K05A1017

Replacement Cartridge, Screen and O-ring 

for 1 in. Valves.

K05B1007

Replacement Screen and O-ring for 3/4 in. 

Valves.

K05B1015

Replacement Screen and O-ring for 1 in. 

Valves.

Union Kits

K06U1077

Union Kit—3/4 in., includes nut, female 

NPT threaded tailpiece and gasket.

K06U1085

Union Kit—1 in., includes nut, female NPT 

threaded tailpiece and gasket.

K06U1101

Union Kit—3/4 in., includes nut, sweat 

tailpiece and gasket.

K06U1119

Union Kit—1 in., includes nut, sweat 

tailpiece and gasket.

M32172

INLET OUTLET

Problem

Solution

Whistling noise.

Slightly increase or decrease the outlet pressure until the noise disappears.

Will not hold pressure.

Clean the filter cartridge.

Chatters.

Replace the screen and O-rings.

Replace the cartridge (see replacing the cartridge section).

Freezes up.

Replace bonnet or cartridge, if damaged.

To avoid future freeze-up: 

— Temporarily (slightly) open a downstream faucet if the DS05 is going to be 

exposed to temperatures below 32°F (0°C). The slight water flow will eliminate 

freeze-up. 

— Move the DS05 to a location with an ambient temperature above 32°F (0°C) if it 

is currently exposed to prolonged temperatures below 32°F (0°C).

Pressure gauge measures a lower 

pressure under flow conditions than was 

originally set during static conditions.

DS05 is functioning properly. No action is necessary. The pressure decrease is 

characteristic of all directacting pressure regulating valves and is referred to as 

falloff (See Table 2).

Summary of Contents for D05T

Page 1: ...t is not suitable for steam FEATURES Non corroding unitized cartridge contains all working parts and is easily replaceable Includes built in strainer and thermal bypass Balanced seat construction provides superior pressure regulation Inlet and outlet are internally threaded female NPT and externally threaded for use with union assemblies One year warranty SPECIFICATIONS Model D05T Pressure Regulat...

Page 2: ...ct Number Pipe Size Dimensions Approximate Union Fittings inch DN inch mm D05T1011 3 4 in DN20 6 5 8 in high x 3 1 2 in wide 168 mm high x 89 mm long Union body no tailpieces D05T1029 3 4 in DN20 6 5 8 in high x 5 3 16 in long 168 mm high x 132 mm long Double union sweat D05T1045 1 in DN25 4 1 2 in high x 4 in long 114 mm high x 142 mm wide Union body no tailpieces D05T1052 1 in DN25 8 5 8 in high...

Page 3: ...ownstream isolating valve if used 3 Install the D05T with the arrow on the body pointing in the direction of water flow The D05T can be mounted in any position The D05T can be installed directly onto the pipe by using the female NPT threads on each end If space limitations restrict turning the D05T install single or double unions NOTE Heat from soldering can damage internal parts of the D05T Alway...

Page 4: ...sting screw counterclock wise to remove spring tension 3 Remove the bonnet and washer using an adjustable wrench socket or box end wrench 4 Remove the cartridge using two screwdrivers as levers 5 Attach new O rings and screen onto the new cartridge Make sure O rings are properly installed above and below the screen 6 Insert the new cartridge Do not scratch the sides 7 Place the washer on top of th...

Page 5: ...hown in Fig 3 5 Remove and clean the cartridge screen 6 Replace the cartridge screen and make sure the O rings are installed properly 7 Carefully clean the cartridge seat area 8 Insert the cartridge Do not scratch the sides 9 Place the washer on top of the cartridge NOTE The inner lip must be pointing up to avoid dam aging the diaphragm 10 Replace the spring spring cup and bonnet see Fig 4 11 Read...

Page 6: ...ESIGN PRESSURE REGULATING VALVES 62 3021 03 6 Fig 4 D05T exploded view ADJUSTING SCREW LOCKING NUT BONNET SPRING CUP SPRING WASHER CARTRIDGE O RING SCREEN O RING NUT TAILPIECE GASKET NUT TAILPIECE GASKET M32171 BODY ...

Page 7: ...ket for 1 in D05T DS05 quantity 24 K05A1009 Replacement Cartridge Screen and O ring for 3 4 in Valves K05A1017 Replacement Cartridge Screen and O ring for 1 in Valves K05B1007 Replacement Screen and O ring for 3 4 in Valves K05B1015 Replacement Screen and O ring for 1 in Valves Union Kits K06U1077 Union Kit 3 4 in includes nut female NPT threaded tailpiece and gasket K06U1085 Union Kit 1 in includ...

Page 8: ...ns Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2009 Honeywell International Inc 62 3021 03 T D Rev 07 10 Printed in U S A ...