Honeywell D05T Quick Start Manual Download Page 3

D05T COMPACT DESIGN PRESSURE REGULATING VALVES

3

62-3021—03

Water Capacities (See Table 2)

The suitability of a given regulator size is dependent on the 

pressure requirements of each installation. To determine the 

pressure regulator valve size required for a specific installation, 

determine the following:

1.

Pressure differential between inlet and outlet pressure in 

pounds per square inch (psi),

2.

Capacity in gallons per minute (gpm), and

3.

Allowable reduced pressure falloff in psi.

Given these variables, use Table 2 to determine the proper 

size pressure regulator valve for your application.

Example:An installation has 135 psi inlet pressure, 60 psi out-

let pressure (75 psi pressure differential). If 17 gpm 

capacity is required with only 10 psi falloff allowable, a 

3/4 in. D05T is required.

Table 2. Water Capacities.

a

Velocity in feet per second is based on schedule 40 pipe size. recommended pressure falloff for general use is approximately 104 

kPa (15 psi). Recommended velocities for the flow of water: Residential and general use, 5 to 10 feet per second; industrial use, 

7 to 15 feet per second; boiler feed, 7 to 15 feet per second.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow them 

could damage the product or cause a hazardous condi-

tion.

2.

Check the ratings given in these instructions and on the 

product to make sure the product is suitable for your 

application.

3.

Installer must be a trained, experienced service techni-

cian.

4.

After installation is complete, check out the product oper-

ation as provided in these instructions.

Procedure

1.

Flush the system clear of sediment or debris.

2.

Close the supply valve and downstream isolating valve 

(if used).

3.

Install the D05T with the arrow on the body pointing in 

the direction of water flow. (The D05T can be mounted in 

any position.)

The D05T can be installed directly onto the pipe by using the 

female NPT threads on each end. If space limitations restrict 

turning the D05T, install single- or double-unions.

NOTE: Heat from soldering can damage internal parts of the 

D05T. Always remove the tailpiece(s) from the D05T 

during soldering, or disassemble the D05T prior to 

heating the casting.

4.

Open the supply valve.

Changing the Outlet Pressure (See 
Fig. 2)

The D05T is factory set to 60 psi. To change the outlet 

pressure, turn the adjusting bolt counterclockwise 

 to 

reduce pressure or clockwise 

 to increase pressure. 

To adjust the outlet pressure to a desired setting:

1.

Close the

 

supply shutoff valve and open a downstream 

faucet to relieve static pressure in the line.

2.

Install a pressure gauge inline, downstream of the D05T 

valve.

3.

Loosen the locknut by turning counterclockwise 

   

two turns.

4.

Turn the adjusting bolt counterclockwise 

 several 

turns to make sure the setting is below the desired set-

ting.

5.

Close all downstream valves and/or faucets and slowly 

open the supply valve until fully open.

Pressure Differential Between Inlet and Outlet

Pressure 

Regulator 

Valve Size

Reduced 

Pressure 

Falloff 

(psi)

25 psi 

50 psi

75 psi

100 psi or more

Flow 

Capacity

(US gpm)

Velocity
(ft/sec)

a

Flow 

Capacity 

(US gpm)

Velocity 
(ft/sec)

a

Flow 

Capacity 

(US gpm)

Velocity 
(ft/sec)

a

Flow 

Capacity 

(US gpm)

Velocity 
(ft/sec)

a

3/4 inch

6

9.0

5.4

10.0

6.0

11.0

6.5

12.0

7.1

10

15.0

8.9

16.0

9.5

17.0

10.0

18.0

10.7

15

20.0

11.9

22.0

13.7

23.0

13.7

24.0

14.3

20

23.0

13.9

26.0

17.6

27.0

16.7

28.0

17.3

1 inch

6

11.5

4.2

13.0

4.7

14.5

5.3

16.0

5.8

10

20.0

7.2

21.5

7.8

23.0

8.3

24.5

8.9

15

28.0

10.7

30.0

10.9

33.0

12.0

35.0

12.7

20

32.0

14.0

37.0

13.5

40.0

15.5

41.0

15.0

Summary of Contents for D05T

Page 1: ...t is not suitable for steam FEATURES Non corroding unitized cartridge contains all working parts and is easily replaceable Includes built in strainer and thermal bypass Balanced seat construction provides superior pressure regulation Inlet and outlet are internally threaded female NPT and externally threaded for use with union assemblies One year warranty SPECIFICATIONS Model D05T Pressure Regulat...

Page 2: ...ct Number Pipe Size Dimensions Approximate Union Fittings inch DN inch mm D05T1011 3 4 in DN20 6 5 8 in high x 3 1 2 in wide 168 mm high x 89 mm long Union body no tailpieces D05T1029 3 4 in DN20 6 5 8 in high x 5 3 16 in long 168 mm high x 132 mm long Double union sweat D05T1045 1 in DN25 4 1 2 in high x 4 in long 114 mm high x 142 mm wide Union body no tailpieces D05T1052 1 in DN25 8 5 8 in high...

Page 3: ...ownstream isolating valve if used 3 Install the D05T with the arrow on the body pointing in the direction of water flow The D05T can be mounted in any position The D05T can be installed directly onto the pipe by using the female NPT threads on each end If space limitations restrict turning the D05T install single or double unions NOTE Heat from soldering can damage internal parts of the D05T Alway...

Page 4: ...sting screw counterclock wise to remove spring tension 3 Remove the bonnet and washer using an adjustable wrench socket or box end wrench 4 Remove the cartridge using two screwdrivers as levers 5 Attach new O rings and screen onto the new cartridge Make sure O rings are properly installed above and below the screen 6 Insert the new cartridge Do not scratch the sides 7 Place the washer on top of th...

Page 5: ...hown in Fig 3 5 Remove and clean the cartridge screen 6 Replace the cartridge screen and make sure the O rings are installed properly 7 Carefully clean the cartridge seat area 8 Insert the cartridge Do not scratch the sides 9 Place the washer on top of the cartridge NOTE The inner lip must be pointing up to avoid dam aging the diaphragm 10 Replace the spring spring cup and bonnet see Fig 4 11 Read...

Page 6: ...ESIGN PRESSURE REGULATING VALVES 62 3021 03 6 Fig 4 D05T exploded view ADJUSTING SCREW LOCKING NUT BONNET SPRING CUP SPRING WASHER CARTRIDGE O RING SCREEN O RING NUT TAILPIECE GASKET NUT TAILPIECE GASKET M32171 BODY ...

Page 7: ...ket for 1 in D05T DS05 quantity 24 K05A1009 Replacement Cartridge Screen and O ring for 3 4 in Valves K05A1017 Replacement Cartridge Screen and O ring for 1 in Valves K05B1007 Replacement Screen and O ring for 3 4 in Valves K05B1015 Replacement Screen and O ring for 1 in Valves Union Kits K06U1077 Union Kit 3 4 in includes nut female NPT threaded tailpiece and gasket K06U1085 Union Kit 1 in includ...

Page 8: ...ns Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2009 Honeywell International Inc 62 3021 03 T D Rev 07 10 Printed in U S A ...