Honeywell CX Series Installation And Service Instructions Manual Download Page 6

CX Series

 

ISSUE 4

   PK 88136

 

C A U T I O N

U S E   O N L Y

N O N - S P A R K I N G

A C T U A T O R S

12,1
0.48

Without

Wire Lead

     2 X M25 X 1,5 (6 full threads min)

105,3

4.15

143,0

5.63

 

 

WARNING 

Sensing and Control 
www.honeywell.com/sensing 

Honeywell 
11 West Spring Street 

 

OPENING PRODUCTS HAZARD 
DO NOT OPEN

 these products when energized or 

in a flammable gas atmosphere.  

Failure to comply with these instructions could 
result in death or serious injury.

 

 

WARNING

 

IMPROPER CONDUIT THREAD USE 
DO NOT USE 

any other conduit thread than the 

one identified on the product. Verify that the mating 
threaded fitting is identical with the conduit thread 
shown on the product nameplate.

 

Failure to comply with these instructions could 
result in death or serious injury.

 

 
 

WARRANTY/REMEDY 

Honeywell warrants goods of its manufacture as 

being free of defective materials and faulty 
workmanship. Contact your local sales office for 
warranty information. If warranted goods are 
returned to Honeywell during the period of 
coverage, Honeywell will repair or replace without 
charge those items it finds defective.

 The 

foregoing is Buyer’s sole remedy and is in lieu 
of all other warranties, expressed or implied, 
including those of merchantability and fitness 
for a particular purpose. 

Specifications may change without notice. The 

information we supply is believed to be accurate 
and reliable as of this printing. However, we 
assume no responsibility for its use. 

While we provide application assistance 

personally, through our literature and the Honeywell 
web site, it is up to the customer to determine the 
suitability of the product in the application. 

For application assistance, current specifications, 

or name of the nearest Authorized Distributor, 
check the Honeywell web site or call: 
1-800-537-6945 USA/Canada 
1-815-235-6847 International 

FAX 

1-815-235-6545 USA

 

INTERNET 

www.honeywell.com/sensing 
[email protected] 

 

Freeport, Illinois 61032 
 

PK 88136-4-EN  IL50 GLO   404   Printed in USA 
Copyright 2004 Honeywell International Inc.  All Rights Reserved. 

 

 

Summary of Contents for CX Series

Page 1: ...uipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres 94 9 EC commonly referred to as the ATEX Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN50014 1997 EN50018 1994 and EN50281 1 1 The European approved products have a temperature range of 40 C to 70 C 40 F to 158 F and when used within the maximum voltag...

Page 2: ...s obtained Operation is in the direction of the inclined surface of the symbol when or lines up with the pointer on the cam follower 4 When cam wheel has been rotated to desired location release cam wheel to engage with mating shaft disc 5 Release cam follower CX Wiring Methods Honeywell recommends that conduit be installed per NEC articles 501 4 and 501 5 REPLACEMENT PARTS Replacement switch asse...

Page 3: ...CX 282CX 92CX 14CX 24CX 64CX 74CX 84CX 284CX 94CX 16CX 26CX 66CX 76CX 86CX 286CX 96CX 1172CX 2172CX 9172CX Pretravel max 15 15 30 30 15 Differential Travel max 5 10 25 20 5 Overtravel min 90 90 75 75 90 Circuitry Single Pole Double Throw Single Pole Double Throw Double Pole Double Throw Single Pole Double Throw Gold Contact Single Pole Double Throw Electrical Ratings UL CSA Rating L96 15 A 120 240...

Page 4: ...itial position Next rotate shaft a half 180 turn CW and then a half turn CCW back to initial position Use Step 2 if the function switch is set in the CCW position 2 Rotate operating shaft a quarter turn 90 CW and then a quarter turn CCW back to the initial position Next rotate shaft a half turn 180 CCW and then a half turn CW back to initial position Procedure 3 1 Wiring See figure 3 Connect a 12 ...

Page 5: ...4 37 MAX 104 4 09 MAX 96 3 78 Ø 98 3 86 TYP 12 7 50 20 3 80 25 4 1 00 Ø 97 3 82 20 3 80 25 4 1 00 22 3 88 9 4 37 MAX 145 5 71 MAX 133 5 24 MAX 145 5 71 MAX 133 5 24 5 1 20 19 4 76 20 3 80 25 4 1 00 Ø 98 3 86 TYP 12 7 50 20 3 80 25 4 1 00 MAX 96 3 78 MAX 104 4 09 5 1 20 19 4 76 TYP 60 3 2 38 40 1 57 18 3 72 80 3 15 101 6 4 00 50 8 2 00 4X F THRU 8 5 33 F MAX 31 4 1 23 Ø 97 3 82 70 29 1 THESEHOLESNO...

Page 6: ...warranty information If warranted goods are returned to Honeywell during the period of coverage Honeywell will repair or replace without charge those items it finds defective The foregoing is Buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose Specifications may change without notice The information...

Reviews: