Honeywell CX Series Installation And Service Instructions Manual Download Page 3

CX Series

 

ISSUE 4

   PK 88136

 

REPLACEMENT LEVERS 

To order replacement levers, order the part 

number which is metal stamped on either the lever 
or the hub. 

Only nonsparking levers can be used 

to retain the explosion-proof properties. 

 

MOUNTING ADAPTER —15PA148-CX 

Available for adapting CX to existing 2 hole 

mount. 

22,9

0.9

21,8

0.85

80

3.15

8,4

0.33

(2)

5/16 -18 UNC (4)

Centerline of CX

Shaft

80

3.15

12,2

0.48

104,4

4.11

 

ANALOG POSITION-SENSING UNITS 

1. 

Resistive Output

 

Specifications: 
500 ohms ±10% in center (free position) 
975 ohms max. at 105° rotation clockwise (CW) 
25 ohms min. at 105° rotation CCW 
2 watts power at 70°C/150°F at full scale 

 
Wiring Diagram 

 

2. 

Current Output (4 to 20 mA)

 

The signal from the position-sensing unit is 
converted to a two-wire 4 to 20 mA current 
output. 
 
Specifications: 
Voltage compliance range: 12.5 to 40 VDC 
Maximum load resistance: 

mA

 

20

12.5

Supply

max

R

L

=

 

Current signal output: 4-20mA 
Span: Adjustable from 15° to 90° of angular 
rotation 
Null: 4 mA position may be set at any angular 
position 
 
Typical Wiring Connections: 
 

 

 

ROTARY ACTUATION 

Catalog Listing Prefix 
(*listing indicates 
replacement parts) 

11CX, 21CX, 61CX, 
71CX, 81CX, 281CX, 
91CX* 

12CX, 22CX, 62CX, 
72CX, 82CX, 282CX, 
92CX* 

14CX, 24CX, 64CX, 
74CX, 84CX, 284CX, 
94CX* 

16CX, 26CX, 66CX, 
76CX, 86CX, 286CX, 
96CX* 

1172CX, 2172CX, 
9172CX* 

Pretravel, 

max. 

15° 15° 30° 30° 15° 

Differential Travel, 
max. 

5°  10° 25° 20° 5° 

Overtravel, 

min. 

90° 90° 75° 75° 90° 

Circuitry Single-Pole 

Double-

Throw 

Single-Pole Double-
Throw 

Double-Pole Double-
Throw 

Single-Pole Double-
Throw 

(Gold Contact) Single-
Pole Double-Throw 

Electrical Ratings 

UL/CSA Rating: L96 
15 A, 120, 240, or 480 
Vac. 

 Hp, 120 Vac; ¼ Hp, 

240 Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc.

 

UL/CSA Rating: L23 
20 A, 120, 240, or 480 
Vac. 
1 Hp, 120 Vac; 2 Hp, 240 
Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc.

 

UL/CSA Rating: L59 
10 A, 120 or 240 Vac. 
0.3 A, 125 Vdc, 0.15 A, 
250 Vdc.

 

UL/CSA Rating: L22 
1 A, 125 Vac.

 

UL/CSA Rating: L22 
1 A, 125 Vac

 

 

PLUNGER ACTUATION 

Catalog Listing Prefix 
(*listing indicates 
replacement parts) 

31CX, , 41CX, 
101CX* 

32CX, 42CX, 102CX* 

 

36CX, 46CX, 106CX* 

3172CX 

Circuitry Single-Pole 

Double-

Throw 

Single-Pole Double-
Throw 

 

Single-Pole Double-
Throw 

(Gold Contact) Single-
Pole Double-Throw 

Electrical Ratings 

UL/CSA Rating: L96 
15 A, 120, 240, or 480 
Vac. 

 Hp, 120 Vac; ¼ Hp, 

240 Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc.

 

UL/CSA Rating: L23 
20 A, 120, 240, or 480 
Vac. 
1 Hp, 120 Vac; 2 Hp, 240 
Vac 
0.5 A, 125 Vdc, 0.25 A, 
250 Vdc.

 

 

UL/CSA Rating: L22 
1 A, 125 Vac. 

 

UL/CSA Rating: L22 
1 A, 125 Vac

 

Pretravel, max. 

2,5 mm [0.10 in] 

Differential Travel, 
max. 

1 mm [0.04 in] 

 

2 mm [0.08 in] 

1 mm [0.04 in] 

Overtravel, min. 

4,75 mm [0.19 in] 

 Honeywell 

 Sensing and Control   

3

   

Summary of Contents for CX Series

Page 1: ...uipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres 94 9 EC commonly referred to as the ATEX Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN50014 1997 EN50018 1994 and EN50281 1 1 The European approved products have a temperature range of 40 C to 70 C 40 F to 158 F and when used within the maximum voltag...

Page 2: ...s obtained Operation is in the direction of the inclined surface of the symbol when or lines up with the pointer on the cam follower 4 When cam wheel has been rotated to desired location release cam wheel to engage with mating shaft disc 5 Release cam follower CX Wiring Methods Honeywell recommends that conduit be installed per NEC articles 501 4 and 501 5 REPLACEMENT PARTS Replacement switch asse...

Page 3: ...CX 282CX 92CX 14CX 24CX 64CX 74CX 84CX 284CX 94CX 16CX 26CX 66CX 76CX 86CX 286CX 96CX 1172CX 2172CX 9172CX Pretravel max 15 15 30 30 15 Differential Travel max 5 10 25 20 5 Overtravel min 90 90 75 75 90 Circuitry Single Pole Double Throw Single Pole Double Throw Double Pole Double Throw Single Pole Double Throw Gold Contact Single Pole Double Throw Electrical Ratings UL CSA Rating L96 15 A 120 240...

Page 4: ...itial position Next rotate shaft a half 180 turn CW and then a half turn CCW back to initial position Use Step 2 if the function switch is set in the CCW position 2 Rotate operating shaft a quarter turn 90 CW and then a quarter turn CCW back to the initial position Next rotate shaft a half turn 180 CCW and then a half turn CW back to initial position Procedure 3 1 Wiring See figure 3 Connect a 12 ...

Page 5: ...4 37 MAX 104 4 09 MAX 96 3 78 Ø 98 3 86 TYP 12 7 50 20 3 80 25 4 1 00 Ø 97 3 82 20 3 80 25 4 1 00 22 3 88 9 4 37 MAX 145 5 71 MAX 133 5 24 MAX 145 5 71 MAX 133 5 24 5 1 20 19 4 76 20 3 80 25 4 1 00 Ø 98 3 86 TYP 12 7 50 20 3 80 25 4 1 00 MAX 96 3 78 MAX 104 4 09 5 1 20 19 4 76 TYP 60 3 2 38 40 1 57 18 3 72 80 3 15 101 6 4 00 50 8 2 00 4X F THRU 8 5 33 F MAX 31 4 1 23 Ø 97 3 82 70 29 1 THESEHOLESNO...

Page 6: ...warranty information If warranted goods are returned to Honeywell during the period of coverage Honeywell will repair or replace without charge those items it finds defective The foregoing is Buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose Specifications may change without notice The information...