INSTALLATION INSTRUCTIONS
69-1863-03
CS8800 Water Heater
Pilot Burner Assembly
APPLICATION
The CS8800 Pilot Burner Assemblies provides standing
pilot ignition of the main burner and power for the
WT8800 control module and VT8800 valve. The CS8800
is a primary aerated pilot burner.
On some models a temperature cut out switch (TCO) is
provided to sense a clogged flame arrestor or a
flammable vapor incident. When the TCO opens, the
power to the control is interrupted and pilot goes out.
There are separate LP and natural gas models.
The CS8800 Pilot Burner was designed for gas fired hot
water tank heating applications.
SPECIFICATIONS
Maximum Temperature Ratings:
Target (flame hood)
1575
°
F
Orifice
600
°
F (800
°
F for models using
stainless steel gas connections)
Bracket Assembly
1000
°
F
Appliance Operating Ambient Temperature Range:
32
°
F to 140
°
F (0
°
C to 60
°
C)
Orifice Requirements:
CS8800A Natural Gas: 0.013 to 0.0143 in. (480 BTU/hr
to 580 BTU/hr at 4.5 in. WC)
CS8800B LP Gas: 0.007 to 0.0083 in. (340 BTU/hr to
480 BTU/hr at 10 in. WC)
CS8800C Natural Gas: 0.0155 to 0.0165 in. (685 BTU/hr
to 776 BTU/hr at 4.5 in. WC)
CS8800D LP Gas: 0.0115 to 0.0125 in. (910 BTU/hr to
1075 BTU/hr at 10 in. WC)
Models:
There are four models available:
CS8800A: “U” channel bracket for burner base
mounting.
CS8800B: Angle bracket for main burner tube
mounting.
CS8800C: Angle bracket similar to CS8800B except
designed to light burner from above.
CS8800D: Angle bracket same as CS8800B.
WARNING
Oxygen Depletion Hazard.
Can cause injury or death due to asphyxiation.
1. Use this pilot burner on vented appliances only.
2. Replace pilot burner with same exact part
number. If equipped with a TCO switch, it must
be installed in the location provided on the pilot
burner. If the TCO switch is mounted on the
appliance, connect the thermopile leads to the
TCO switch. Follow the Instructions provided
with replacement pilot burner.
INSTALLATION
When Installing This Product…
1.
Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.
2.
Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3.
Make sure the installer is a trained, experienced
service technician.
4.
After completing the installation, use these
instructions to check out the product operation.
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury
or death.
Follow these warnings exactly:
1. Avoid dangerous accumulation of fuel gas by
turning off gas supply at the appliance service
valve before starting the installation procedure.
2. Perform the Gas Leak Test (see page 2) after
the completion of the installation.
3. Do not bend pilot tubing at the gas control or
pilot burner after the compression nut is
tightened. Gas leakage at the connection can
result.
Follow the appliance manufacturer instructions if
available; otherwise, use the instructions provided below.
Location
1.
Position the pilot burner for easy access and
observation. In replacement applications, replace
the pilot burner with an identical unit and position
the new pilot burner in the same location and
orientation as the original pilot burner. If the model
has a TCO, position and attach the TCO in the
exact location as the original TCO. If the model has
terminals to connect a TCO, connect the TCO.
2.
Mount the pilot burner on the main burner. See
Fig. 1. Mounting surfaces other than the main
burner can shift, bend, or warp as the water heater
tank expands and contracts during operation.