C6097 · Edition 01.19
22
Technical data
6 .3 UL, FM certified pressure switches
Switching capacity:
U = 24 – 240 V AC,
I = max. 5 A at cos
ϕ
= 1,
I = max. 0.5 A at cos
ϕ
= 0.6.
Maximum medium and ambient temperatures:
-40 to +60°C (-40 to +140°F).
Line entrance:
½" NPT conduit.
Cable diameter: AWG 24 to AWG 13,
0.02 to 0.07" (0.5 to 1.8 mm).
6 .4 Adjusting range, switching hysteresis
6 .4 .1 CE certified pressure switches
Type
Adjusting
range*
mbar
Mean switching
differential at min. and
max. setting
mbar
Max. inlet pressure
p
max.
= withstand
pressure
mbar
Difference between
switching pressure and
possible reset
mbar
Deviation from the switching point during
testing pursuant to EN 1854
Gas pressure switch
Air pressure switch
C6097A4110
1 – 10
0.25 – 0.4
500
–
± 15%
± 15%
C6097A4210
2.5 – 50
0.8 – 1.5
500
–
± 15%
± 15%
C6097A4310
30 – 150
3 – 5
600
–
± 15%
± 15%
C6097A4410 100 – 500
8 – 17
600
–
± 15%
± 15%
* Adjusting tolerance = ± 15% of the scale value.
Switching properties, see page 4 (Use).
▼