1
69-2245EF
Honeywell’s AQ1000TP2 is a programmable thermostat designed to be used with an AQ2000 Series
hydronic control panel to operate a hydronic system, a HVAC system or both. It displays both indoor and
outdoor temperatures and incorporates the following functions:
About your new thermostat
A/F/AF regulation modes:
The thermostat can control the ambient air temperature (
A
), the floor temperature (
F
) or
the ambient air temperature with floor temperature limits (
AF
) (see page 19).
System Heat/Cool modes:
The thermostat can activate a
heating
system or a
cooling
system. The thermostat can
also be placed in the
off
position when neither heating nor cooling is required (see
page 5).
Fan On/Auto modes:
When the thermostat is used to activate a fan, the latter can be placed in
Auto
or
On
mode (see page 6).
Programmable schedule:
The thermostat can be programmed to use up to
4 periods per day
. Each of the 28
periods for the week can have its own start time and temperature setpoints (see page 9).
Thermostat modes:
The thermostat can be placed in any of the following modes (see page 4):
•
In
Hold mode
, the setpoint must be set manually.
•
In
Run mode
, the setpoint is adjusted according to the programmed schedule.
•
The thermostat enters
Temporary Hold mode
when the setpoint is temporarily
overridden while in Run mode.
•
When the
Unoccupied mode
is activated by the hydronic control panel, the
setpoint is set back by a predetermined temperature margin.
•
When the
Vacancy mode
is activated by the hydronic control panel for further
energy savings during periods of extended vacancy, the setpoint will be set to a
lower value if the thermostat is in heat mode or to higher value in cool mode.
400-146-001-A_69-2245EF (AQ1000TP2) ENG.fm Page 1 Wednesday, June 18, 2008 2:32 PM